| Input Number of Phases | 3 AC |
| Input Line Voltage | 380 ... 440 V +10%-20% |
| Input Line Frequency | 47 ... 63 Hz |
| Input Rated Current (LO) | 3.60 A |
| Output Number of Phases | 3 AC |
| Output Rated Voltage | 400 V |
| Output Rated Power IEC 400V (LO) | 1.50 kW |
| Output Rated Current 400V (IN) | 4.10 A |
| Output Rated Current 380V (IN) | 4.10 A |
| Output Rated Current (LO) | 4.10 A |
| Output Max. Output Current | 4.50 A |
| Output Pulse Frequency | 4 kHz |
| Output Frequency for Vector Control | 0 ... 240 Hz |
| Output Frequency for V/f Control | 0 ... 550 Hz |
| Overload Capability (Low Overload LO) | 110% base load current IL for 60 s in a 600 s cycle time |
| Power Factor λ | 0.75 ... 0.93 |
| Power Factor cos φ 1 | 0.99 |
| Efficiency η | 0.97 |
| Sound Pressure Level (1m) | 55 dB |
| Power Loss | 0.072 kW |
| Integrated Filter Class | Unfiltered |
| EMC Category (with accessories) | without |
| Safety Function Safe Torque Off | without SIRIUS device (e.g. via S7-1500F) |
| Communication Protocols | USS, Modbus RTU, BACnet MS/TP |
| Standard Digital Inputs Number | 6 |
| Standard Digital Inputs Switching Level 0 → 1 | 11 V |
| Standard Digital Inputs Switching Level 1 → 0 | 5 V |
| Standard Digital Inputs Max. Inrush Current | 15 mA |
| Fail-safe Digital Inputs Number | 0 |
| Digital Outputs Number as Relay Changeover Contact | 4 |
| Digital Outputs (Resistive Load) | DC 30 V, 1.0 A |
| Digital Outputs Number as Transistor | 0 |
| Analog / Digital Inputs Number | 2 (Differential input) |
| Analog / Digital Inputs Resolution | 12 bit |
| Analog / Digital Inputs Switching Threshold 0-1 | 4 V |
| Analog / Digital Inputs Switching Threshold 1-0 | 1.6 V |
| Analog Outputs Number | 2 (Non-isolated output) |
| PTC/KTY Interface | 1 motor temperature sensor input, sensors that can be connected: PTC, KTY, PT1000 and Thermo-Click, accuracy ±5 °C |
| V/f Linear / Square-law / Parameterizable | Yes |
| V/f with Flux Current Control (FCC) | Yes |
| V/f ECO Linear / Square-law | Yes |
| Sensorless Vector Control | Yes |
| Vector Control, with Sensor | No |
| Encoderless Torque Control | Yes |
| Torque Control, with Encoder | No |
| Standard Board Coating Type | Class 3C2, according to IEC 60721-3-3: 2002 |
| Cooling Method | Air cooling using an integrated fan |
| Cooling Air Requirement | 0.005 m³/s (0.177 ft³/s) |
| Installation Altitude | 1,000 m (3,280.84 ft) |
| Operating Ambient Temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Transport Ambient Temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Storage Ambient Temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Max. Operating Relative Humidity | 95% At 40 °C (104 °F), condensation and icing not permissible |
| Signal Cable Conductor Cross-section | 0.15 ... 1.50 mm² (AWG 24 ... AWG 16) |
| Line Side Connection Version | Screw-type terminal |
| Line Side Conductor Cross-section | 1.50 ... 2.50 mm² (AWG 16 ... AWG 14) |
| Motor End Connection Version | Screw-type terminals |
| Motor End Conductor Cross-section | 1.50 ... 2.50 mm² (AWG 16 ... AWG 14) |
| PE Connection | On housing with M4 screw |
| Max. Motor Cable Length (Shielded) | 150 m (492.13 ft) |
| Max. Motor Cable Length (Unshielded) | 300 m (984.25 ft) |
| Degree of Protection | IP20 / UL open type |
| Frame Size | FSA |
| Compliance with Standards | CE, EAC, RCM, RoHS II |
| CE Marking | EMC Directive 2004/108/EC, Low-Voltage Directive 2006/95/EC |
| Converter Efficiency Class | IE2 |
| Comparison with Reference Converter (90% / 100%) | 35.3% |
| Physical Weight (kg) | 3.1 |
| Dimensions L x W x H (cm) | 20.9 x 7.3 x 23.2 |