Sale!

Festo 150380 Inductive Sensor, NPN NC, 1.5 mm, 6.5 mm

Original price was: USD 68.38.Current price is: USD 59.54.

Flush 6.5 mm inductive sensor with 1.21 mm assured distance, 5000 Hz switching, 2.5 m three-core PUR cable and 10–30 V DC supply.

SKU Festo-150380 Category
Festo Inductive Sensors

Festo SIEN-6,5B-NO-K-L Inductive Proximity Sensor

BrandFesto
Model IdentifierSIEN-6,5B-NO-K-L
Official Part Number150380

Technical Overview

The Festo SIEN-6,5B-NO-K-L is a 6.5 mm inductive proximity sensor with an NPN normally closed output and flush installation. Its rated operating distance is 1.5 mm, with a 1.21 mm assured distance and 0.07 mm repetition accuracy under constant conditions. Material reduction factors distinguish steel, stainless steel and non-ferrous targets, while the maximum switching frequency is 5000 Hz. The 10–30 V DC sensor provides up to 200 mA output current through a 2.5 m three-core PUR cable with open ends. Clamping secures the body, and a yellow LED indicates switching state. The 45 g unit has IP65/IP67 protection.

Flush 6.5 mm inductive sensor with NPN normally closed output, 1.5 mm rated distance, 5000 Hz maximum switching and 2.5 m open-ended cable.

Key Features

  • 1.5 mm rated and 1.21 mm assured operating distances
  • NPN normally closed output
  • 6.5 mm body for flush installation with clamped mounting
  • 5000 Hz maximum switching frequency
  • 0.07 mm repetition accuracy under constant conditions
  • 0.07 mm hysteresis
  • 10–30 V DC supply and 200 mA maximum output current
  • 2.5 m three-core open-ended PUR cable
  • IP65/IP67 protection with yellow switching LED
  • 45 g product weight and −25 to +70 °C ambient range

Detect nearby metal targets at a 1.5 mm rated distance using a flush 6.5 mm sensor with NPN normally closed output and 5000 Hz maximum switching.

Technical Specification Matrix

ParameterValue
Conforms to standardEN 60947-5-2
ApprovalRCM; c UL us - Listed (Oil)
CE mark (see declaration of conformity)To EU EMC Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)according to UK instructions for EMC (UK-E); according to UK RoHS instructions (UK-R)
Rated operating distance1.5 mm
Assured operating distance1.21 mm
Reduction factorsAluminium = 0.25; Stainless steel St 18/8 = 0.7; Copper = 0.2; Brass = 0.35; Steel St 37 = 1.0
Ambient temperature-25 °C...70 °C
Repetition accuracy with constant conditions0.07 mm
Switching outputNPN
Switching element functionN/C contact
Hysteresis0.07 mm
Max. switching frequency5000 Hz
Max. output current200 mA
Voltage drop2 V
Inductive protective circuitIntegrated
Short circuit current ratingPulsed
Operational voltage range DC10 V...30 V
Residual ripple± 10%
No-load supply current10 mA
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typeCable
Electrical connection 1, connector systemOpen end
Electrical connection 1, number of connections/cores3
Cable length2.5 m
Material cable sheathTPE-U(PUR)
Size6.5 mm
Type of mountingClamped
Mounting typeFlush
Physical Weight (kg)0.045
Material housingPA; High-alloy stainless steel
Switching status indicationYellow LED
Ambient temperature with moving cable-5 °C...70 °C
Degree of protectionIP65; IP67
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B2-L
Additional information for sensor selectionWith standards-based switching distance
Electrical outputNPN
Selection of sensor designStandard
Measuring principleInductive

Industrial Applications

1. Position Confirmation at a Compact Sensor Mount

A machine mechanism needs a non-contact signal when a suitable metal target reaches a defined position. The 6.5 mm sensor uses clamped mounting and permits flush installation for this exact version. Its 1.5 mm rated distance, 1.21 mm assured distance and 0.07 mm repetition accuracy under constant conditions characterize the documented switching geometry for the position target.

Problem Solved

Clamped mounting locates the inductive switching point near the mechanism, providing a position signal through the normally closed NPN output without requiring physical contact with the target.

6.5 mm clamped mounting 1.5 mm rated distance NPN NC

2. Pulse Counting from Separated Metal Index Features

A machine controller counts passing metal index features to observe repeated mechanical cycles. Each suitable target entering and leaving the inductive field changes the NPN normally closed output, and the 5000 Hz maximum switching frequency defines the component response limit. The three-core open-ended cable and 10–30 V DC supply provide the electrical interface, while actual target spacing and circuit timing determine usable pulse separation.

Problem Solved

Inductive switching converts separated metal index passages into electrical pulses, supplying the controller with events for cycle counting through a documented industrial sensor interface.

5000 Hz maximum NPN normally closed Three-core open cable

3. Missing Metal Insert Detection in an Assembly Nest

An assembly nest needs to detect whether a metal insert is present before the next processing step. The inductive sensor provides an NPN normally closed switching result rather than an image or material-identification output. Published reduction factors of 1.0 for steel St 37, 0.7 for stainless steel St 18/8 and 0.25 for aluminium define important material distinctions when evaluating the sensing gap.

Problem Solved

The switching output supplies a presence result for the metal insert, allowing the assembly sequence to distinguish a detected target from an empty sensing location.

Metal insert presence Material reduction factors NPN normally closed
Select your currency