General information | |
Product type designation | CPU 1510SP F-1 PN |
HW functional status | FS04 |
Firmware version ● FW update possible |
V4.0 Yes |
Product function | |
● I&M data ● Module swapping during operation (hot swapping) ● Isochronous mode ● SysLog |
Yes; I&M0 to I&M3 Yes; Multi-hot swapping Yes; only with PROFINET; with minimum OB 6x cycle of 500 µs Yes |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated from version | V20 (FW V4.0) / V18 (FW V3.0) or higher; configurable with older TIA Portal versions as 6ES7510-1SJ01-0AB0 |
Configuration control | |
via dataset | Yes |
Control elements | |
Mode selector switch | 1 |
Supply voltage | |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Mains buffering | |
● Mains/voltage failure stored energy time | 10 ms |
Input current | |
Current consumption (rated value) | 0.48 A |
Current consumption, max. | 0.7 A |
Inrush current, max. | 1.34 A ; Rated value |
I²t | 0.3 A²·s |
Power | |
Infeed power to the backplane bus | 8.05 W |
Work memory | |
● integrated (for program) ● integrated (for data) |
300 kbyte 1 Mbyte |
Load memory | |
● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte |
Backup | |
● maintenance-free | Yes |
CPU processing times | |
for bit operations, typ. for word operations, typ. 7 ns for fixed point arithmetic, typ. 9 ns for floating point arithmetic, typ. |
6ns 7ns 9ns 37ns |
CPU-blocks | |
Number of elements (total) | 4 000; Blocks (OB, FB, FC, DB) and UDTs |
DB | |
Number range
● Size, max. |
1 … 60 999; subdivided into: number range that can be used by the user: 1 … 59 999, and number range of DBs created via SFC 86: 60 000 … 60 999 1 Mbyte; For DBs with absolute addressing, the max. size is 64 KB |
FB | |
● Number range ● Size, max. |
0 … 65 535 300 kbyte |
FC | |
● Number range ● Size, max. |
0 … 65 535 300 kbyte |
OB | |
● Size, max. ● Number of free cycle OBs ● Number of time alarm OBs ● Number of delay alarm OBs ● Number of cyclic interrupt OBs ● Number of process alarm OBs ● Number of DPV1 alarm OBs ● Number of isochronous mode OBs ● Number of technology synchronous alarm OBs ● Number of startup OBs ● Number of asynchronous error OBs ● Number of synchronous error OBs ● Number of diagnostic alarm OBs |
300 kbyte 100 20 20 20; With minimum OB 3x cycle of 250 μs 50 3 1 2 100 4 2 1 |
Nesting depth | |
● per priority class | 24; Up to 8 possible for F-blocks |
Counters, timers and their retentivity | |
S7 counter | |
● Number | 2 048 |
Retentivity | |
— adjustable | Yes |
IEC counter | |
● Number | Any (only limited by the main memory) |
Retentivity | |
— adjustable | Yes |
S7 times | |
● Number | 2 048 |
Retentivity | |
— adjustable | Yes |
IEC timer | |
● Number | Any (only limited by the main memory) |
Retentivity | |
— adjustable | Yes |
Data areas and their retentivity | |
Retentive data area (incl. timers, counters, flags), max. | 256 kbyte; in total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 216 KB |
Flag | |
● Size, max. ● Number of clock memories |
16 kbyte 8; 8 clock memory bit, grouped into one clock memory byte |
Data blocks | |
● Retentivity adjustable ● Retentivity preset |
Yes No |
Local data | |
● per priority class, max. | 64 kbyte; max. 16 KB per block |
Address area | |
Number of IO modules | 2 048; max. number of modules / submodules |
I/O address area | |
● Inputs ● Outputs |
32 kbyte; All inputs are in the process image 32 kbyte; All outputs are in the process image |
per integrated IO subsystem | |
— Inputs (volume) — Outputs (volume) |
8 kbyte 8 kbyte |
per CM/CP | |
— Inputs (volume) — Outputs (volume) |
8 kbyte 8 kbyte |
Subprocess images | |
● Number of subprocess images, max. | 32 |
Address space per module | |
● Address space per module, max. | 288 byte; For input and output data respectively |
Address space per station | |
● Address space per station, max. | 2 560 byte; for central inputs and outputs; depending on configuration; 2 048 bytes for ET 200SP modules + 512 bytes for ET 200AL modules |
Hardware configuration | |
Number of distributed IO systems | 32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) |
Number of DP masters | |
● Via CM | 1 |
Number of IO Controllers | |
● integrated ● Via CM |
1 0 |
Rack | |
● Modules per rack, max.
● Quantity of operable ET 200SP modules, max. |
82; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules 64 16 1 |
PtP CM | |
Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots |
Time of day | |
Clock | |
● Type Hardware clock ● Backup time ● Deviation per day, max. |
Hardware clock 6 wk; At 40 °C ambient temperature, typically 10 s; Typ.: 2 s |
Operating hours counter | |
● Number | 16 |
Clock synchronization | |
● supported ● to DP, master ● on DP, device ● in AS, master ● in AS, device ● on Ethernet via NTP |
Yes Yes; Via CM DP module Yes; Via CM DP module Yes Yes Yes |
Interfaces | |
Number of PROFINET interfaces Number of PROFIBUS interfaces Optical interface |
1 1; Via CM DP module Yes; Via SIMATIC BusAdapter |
1. Interface | |
Interface types | |
● RJ 45 (Ethernet) | Yes; X1 P3; opt. X1 P1 and X1 P2 via BusAdapter BA 2x RJ45 |
● Number of ports | 3; 1. integr. + 2. via BusAdapter |
● integrated switch | Yes |
● BusAdapter (PROFINET) | Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC |
Protocols | |
● IP protocol ● PROFINET IO Controller ● PROFINET IO Device ● SIMATIC communication ● Open IE communication ● Web server ● Media redundancy |
Yes; IPv4 Yes Yes Yes Yes; Optionally also encrypted Yes Yes |
PROFINET IO Controller | |
Services | |
— Isochronous mode | Yes |
— Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) |
— IRT | Yes |
— PROFIenergy | Yes; per user program |
— Prioritized startup | Yes; Max. 32 PROFINET devices |
— Number of connectable IO Devices, max. | 128; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET |
— Of which IO devices with IRT, max. | 64 |
— Number of connectable IO Devices for RT, max. | 128 |
— of which in line, max. | 128 |
— Number of IO Devices that can be simultaneously activated/deactivated, max. |
8; in total across all interfaces |
— Number of IO Devices per tool, max. | 8 |
— Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
— PROFINET Security Class | 1 |
Update time for IRT | |
— for send cycle of 250 μs | 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 μs of the isochronous OB is decisive |
— for send cycle of 500 μs | 500 μs to 8 ms |
— for send cycle of 1 ms | 1 ms to 16 ms |
— for send cycle of 2 ms | 2 ms to 32 ms |
— for send cycle of 4 ms | 4 ms to 64 ms |
— With IRT and parameterization of “odd” send cycles | Update time = set “odd” send clock (any multiple of 125 μs: 375 μs, 625 μs … 3 875 μs) |
Update time for RT | |
— for send cycle of 250 μs | 250 μs to 128 ms |
— for send cycle of 500 μs | 500 μs to 256 ms |
— for send cycle of 1 ms | 1 ms to 512 ms |
— for send cycle of 2 ms | 2 ms to 512 ms |
— for send cycle of 4 ms | 4 ms to 512 ms |
PROFINET IO Device | |
Services | |
— Isochronous mode | No |
— IRT | Yes |
— PROFIenergy | Yes; per user program |
— Shared device | Yes |
— Number of IO Controllers with shared device, max. | 4 |
— activation/deactivation of I-devices | Yes; per user program |
— Asset management record | Yes; per user program |
— PROFINET Security Class | SNMP Configuration and DCP Read Only |
2. Interface | |
Interface types | |
● RS 485 ● Number of ports |
Yes; Via CM DP module 1 |
Protocols | |
● PROFIBUS DP master ● PROFIBUS DP device ● SIMATIC communication |
Yes Yes Yes |
PROFIBUS DP master | |
● Number of connections, max. ● max. number of DP devices |
48; Of which 4 each reserved for ES and HMI 125; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET |
Services | |
— Equidistance — Isochronous mode — activation/deactivation of DP devices |
No No Yes |
Interface types | |
RJ 45 (Ethernet) | |
● 100 Mbps ● Autonegotiation ● Autocrossing ● Industrial Ethernet status LED |
Yes Yes Yes Yes |
RS 485 | |
● Transmission rate, max. | 12 Mbit/s |
Protocols | |
PROFIsafe | Yes; V2.4 / V2.6 |
Number of connections | |
Number of connections, max. ● Number of connections reserved for ES/HMI/web ● Number of connections via integrated interfaces ● Number of connections per CP/CM ● Number of S7 routing paths |
128; via integrated interfaces of the CPU and connected CPs / CMs 10 88 32 16 |
Redundancy mode | |
● H-Sync forwarding | Yes |
Media redundancy | |
— Media redundancy | Yes; only via BusAdapter |
— MRP | Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client |
— MRP interconnection, supported | Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 |
— MRPD | Yes; Requirement: IRT |
— Switchover time on line break, typ. | 200 ms; For MRP, bumpless for MRPD |
— Number of stations in the ring, max. | 50 |
SIMATIC communication | |
● PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
● S7 routing | Yes |
● Data record routing | Yes |
● S7 communication, as server | Yes |
● S7 communication, as client | Yes |
● User data per job, max. | See online help (S7 communication, user data size) |
Open IE communication | |
● TCP/IP | Yes |
— Data length, max. | 64 kbyte |
— several passive connections per port, supported | Yes |
● ISO-on-TCP (RFC1006) | Yes |
— Data length, max. | 64 kbyte |
● UDP | |
— Data length, max. | 2 kbyte; 1 472 bytes for UDP broadcast |
— UDP multicast | Yes; max. 78 multicast circuits |
● DHCP | Yes |
● DNS | Yes |
● SNMP | Yes |
● DCP | Yes |
● LLDP | Yes |
● Encryption | Yes; Optional |
Web server | |
● HTTP ● HTTPS ● web API |
Yes; Standard and user pages Yes; Standard and user pages |
— Number of sessions, max. | 50 |
— number of simultaneous HTTP calls, max. — HTTP request body, max. |
4 131 072 byte |
OPC UA | |
● Runtime license required | Yes; “Small” license required |
● OPC UA Client | Yes; Data Access (registered Read/Write), Method Call |
— Application authentication | Yes |
— Security policies | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
— User authentication | “anonymous” or by user name & password |
— Number of connections, max. | 4 |
— Number of nodes of the client interfaces, recommended max. |
1000 |
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max. |
300 |
— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. |
20 |
— Number of elements for one call of OPC_UA_MethodGetHandleList, max. |
100 |
— Number of simultaneous calls of the client instructions for session management, per connection, max. |
1 |
— Number of simultaneous calls of the client instructions for data access, per connection, max. |
5 |
— Number of registerable nodes, max. | 5000 |
— Number of registerable method calls of OPC_UA_MethodCall, max. |
100 |
— Number of inputs/outputs when calling OPC_UA_MethodCall, max. |
20 |
● OPC UA Server | Yes; data access (read, write, subscribe), method call, alarms & condition (A&C), custom address space, role-based access control |
— Application authentication | Yes |
— Security policies | available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss |
— User authentication | “anonymous” or by user name & password |
— GDS support (certificate management) | Yes |
— Number of sessions, max. | 32 |
— Number of accessible variables, max. | 50 000 |
— Number of registerable nodes, max. | 10 000 |
— Number of subscriptions per session, max. | 50 |
— Sampling interval, min. | 100 ms |
— Publishing interval, min. | 200 ms |
— Number of server methods, max. | 20; max. 20 concurrently running jobs each for asynchronous instructions OPC_UA_ServerMethodPre and OPC_UA_ServerMethodPost |
— Number of inputs/outputs per server method, max. | 20 |
— Number of monitored items, recommended max. | 4 000; for 1 s sampling interval and 1 s send interval |
— Number of server interfaces, max. | 10 of each “Server interfaces” / “Companion specification” type and 20 of the type “Reference namespace |
— Number of nodes for user-defined server interfaces, max. |
15 000 |
● Alarms and Conditions | Yes |
— Number of program alarms | 100 |
— Number of alarms for system diagnostics | 50 |
Further protocols | |
● MODBUS | Yes; MODBUS TCP |
S7 message functions | |
Number of login stations for message functions, max. | 32 |
number of subscriptions, max. | 250 |
number of tags/attributes for subscriptions, max. | 2 000 |
Program alarms | Yes |
Number of configurable program messages, max. | 5 000; Program messages are generated by the “Program_Alarm” block, ProDiag or GRAPH |
Number of loadable program messages in RUN, max. | 5 000 |
Number of simultaneously active program alarms ● Number of program alarms ● Number of alarms for system diagnostics |
600 100 |
● Number of alarms for motion technology objects | 160 |
Test commissioning functions | |
Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 5 engineering systems |
Status block | Yes; Up to 8 simultaneously (in total across all ES clients) |
Single step | Yes |
Number of breakpoints | 8 |
Profiling | Yes |
Status/control | |
● Status/control variable | Yes; without fail-safe |
● Variables | inputs/outputs, bit memories, DBs, peripheral I/Os (without fail-safe), times, counters |
● Number of variables, max. | |
— of which status variables, max. | 200; per job |
— of which control variables, max. | 200; per job |
Forcing | |
● Forcing ● Forcing, variables ● Number of variables, max |
Yes; without fail-safe peripheral inputs/outputs (without fail-safe) 200 |
Diagnostic buffer | |
● present ● Number of entries, max. — of which powerfail-proof |
Yes 1000 500 |
Traces | |
● Number of configurable Traces ● Memory size per trace, max. |
4 512 kbyte |
Interrupts/diagnostics/status information | |
Diagnostics indication LED | |
● RUN/STOP LED ● ERROR LED ● MAINT LED ● Monitoring of the supply voltage (PWR-LED) ● Connection display LINK TX/RX |
Yes Yes Yes Yes Yes |
Supported technology objects | |
Motion Control | Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool |
● Number of available Motion Control resources for technology objects |
1 120 |
● Required Motion Control resources | |
— per speed-controlled axis — per positioning axis — per synchronous axis — per external encoder — per output cam — per cam track — per probe |
40 80 160 80 20 160 40 |
● Positioning axis | |
— Number of positioning axes at motion control cycle of 4 ms (typical value) |
11 |
— Number of positioning axes at motion control cycle of 8 ms (typical value) |
14 |
Controller ● PID_Compact ● PID_3Step ● PID-Temp |
Yes; Universal PID controller with integrated optimization Yes; PID controller with integrated optimization for valves Yes; PID controller with integrated optimization for temperature |
Counting and measuring ● High-speed counter |
Yes |
Standards, approvals, certificates | |
Ecological footprint | |
● environmental product declaration | Yes |
Global warming potential | |
— global warming potential, (total) [CO2 eq] | 83.2 kg |
— global warming potential, (during production) [CO2 eq] | 22.3 kg |
— global warming potential, (during operation) [CO2 eq] |
61.8kg |
— global warming potential, (after end of life cycle) [CO2 eq] |
-0.949 kg |
Highest safety class achievable in safety mode | |
● Performance level according to ISO 13849-1 ● SIL acc. to IEC 61508 |
PLe SIL 3 |
Probability of failure (for service life of 20 years and repair time of 100 hours) | |
— Low demand mode: PFDavg in accordance with SIL3 |
< 2.00E-05 |
— High demand/continuous mode: PFH in accordance with SIL3 |
< 1.00E-09 |
product functions / security / header | |
PROFINET Security Class | 1 |
signed firmware update | Yes |
Secure Boot | Yes |
safely removing data | Yes |
Ambient conditions | |
Ambient temperature during operation | |
● horizontal installation, min. ● horizontal installation, max. 60 °C ● vertical installation, min. -30 °C; No condensation ● vertical installation, max. |
-30 °C; No condensation 60 °C -30 °C; No condensation 50 °C |
Altitude during operation relating to sea level | |
● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
configuration / header | |
configuration / programming / header | |
Programming language | |
— LAD — FBD — STL — SCL — CFC — GRAPH |
Yes; incl. failsafe Yes; incl. failsafe Yes Yes No Yes |
Know-how protection | |
● User program protection/password protection ● Copy protection ● Block protection |
Yes Yes Yes |
Access protection | |
● protection of confidential configuration data ● Protection level: Write protection ● Protection level: Read/write protection ● Protection level: Write protection for Failsafe ● Protection level: Complete protection ● User administration ● Number of users ● Number of groups ● Number of roles |
Yes Yes Yes Yes Yes Yes; device-wide and centralized 100 100 50 |
programming / cycle time monitoring / header | |
● lower limit ● upper limit |
adjustable minimum cycle time adjustable maximum cycle time |
Dimensions | |
Width Height Depth |
100 mm 117 mm 75 mm |
Weights | |
Weight, approx. | 265 g |
Weight | 0.340 kg |
---|---|
Dimensions | 13.3 × 13.5 × 8.2 cm |