SIMATIC ET 200SP – CPU 1510SP F-1 PN – Fail-safe CPUs – Siemens PLC

$ 1,365.05

SKU 6ES7510-1SK03-0AB0 Category

Specifications

General information
Product type designation CPU 1510SP F-1 PN
HW functional status FS04
 Firmware version
● FW update possible
V4.0
Yes
Product function
● I&M data
● Module swapping during operation (hot swapping)
● Isochronous mode
● SysLog
Yes; I&M0 to I&M3
Yes; Multi-hot swapping
Yes; only with PROFINET; with minimum OB 6x cycle of 500 µs
Yes
Engineering with
 ● STEP 7 TIA Portal configurable/integrated from version V20 (FW V4.0) / V18 (FW V3.0) or higher; configurable with older TIA Portal
versions as 6ES7510-1SJ01-0AB0
Configuration control
via dataset Yes
Control elements
Mode selector switch 1
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering
● Mains/voltage failure stored energy time 10 ms
Input current
Current consumption (rated value) 0.48 A
Current consumption, max. 0.7 A
Inrush current, max. 1.34 A ; Rated value
 I²t  0.3 A²·s
Power
Infeed power to the backplane bus 8.05 W
Work memory
● integrated (for program)
● integrated (for data)
300 kbyte
1 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max. 32 Gbyte
Backup
● maintenance-free Yes
CPU processing times
for bit operations, typ.
for word operations, typ. 7 ns
for fixed point arithmetic, typ. 9 ns
for floating point arithmetic, typ.
6ns
7ns
9ns
37ns
CPU-blocks
Number of elements (total) 4 000; Blocks (OB, FB, FC, DB) and UDTs
DB
Number range

● Size, max.

1 … 60 999; subdivided into: number range that can be used by the user: 1 …
59 999, and number range of DBs created via SFC 86: 60 000 … 60 999
1 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
● Number range
● Size, max.
0 … 65 535
300 kbyte
FC
● Number range
● Size, max.
0 … 65 535
300 kbyte
OB
● Size, max.
● Number of free cycle OBs
● Number of time alarm OBs
● Number of delay alarm OBs
● Number of cyclic interrupt OBs
● Number of process alarm OBs
● Number of DPV1 alarm OBs
● Number of isochronous mode OBs
● Number of technology synchronous alarm OBs
● Number of startup OBs
● Number of asynchronous error OBs
● Number of synchronous error OBs
● Number of diagnostic alarm OBs
300 kbyte
100
20
20
20; With minimum OB 3x cycle of 250 μs
50
3
1
2
100
4
2
1
Nesting depth
● per priority class 24; Up to 8 possible for F-blocks
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— adjustable Yes
IEC counter
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
S7 times
● Number 2 048
Retentivity
— adjustable Yes
IEC timer
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 256 kbyte; in total; available retentive memory for bit memories, timers,
counters, DBs, and technology data (axes): 216 KB
Flag
● Size, max.
● Number of clock memories
16 kbyte
8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustable
● Retentivity preset
Yes
No
Local data
● per priority class, max. 64 kbyte; max. 16 KB per block
Address area
Number of IO modules 2 048; max. number of modules / submodules
I/O address area
● Inputs
● Outputs
32 kbyte; All inputs are in the process image
32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume)
— Outputs (volume)
8 kbyte
8 kbyte
per CM/CP
— Inputs (volume)
— Outputs (volume)
8 kbyte
8 kbyte
Subprocess images
● Number of subprocess images, max. 32
Address space per module
● Address space per module, max. 288 byte; For input and output data respectively
Address space per station
● Address space per station, max. 2 560 byte; for central inputs and outputs; depending on configuration; 2 048
bytes for ET 200SP modules + 512 bytes for ET 200AL modules
Hardware configuration
Number of distributed IO systems 32; A distributed I/O system is characterized not only by the integration of
distributed I/O via PROFINET or PROFIBUS communication modules, but also
by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of DP masters
● Via CM 1
Number of IO Controllers
● integrated
● Via CM
1
0
Rack
● Modules per rack, max.

● Quantity of operable ET 200SP modules, max.
● Quantity of operable ET 200AL modules, max.
● Number of lines, max.

82; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET
200AL modules
64
16
1
PtP CM
Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available
slots
Time of day
Clock
● Type Hardware clock
● Backup time
● Deviation per day, max.
Hardware clock
6 wk; At 40 °C ambient temperature, typically
10 s; Typ.: 2 s
Operating hours counter
● Number 16
Clock synchronization
● supported
● to DP, master
● on DP, device
● in AS, master
● in AS, device
● on Ethernet via NTP
Yes
Yes; Via CM DP module
Yes; Via CM DP module
Yes
Yes
Yes
Interfaces
Number of PROFINET interfaces
Number of PROFIBUS interfaces
Optical interface
1
1; Via CM DP module
Yes; Via SIMATIC BusAdapter
1. Interface
Interface types
● RJ 45 (Ethernet) Yes; X1 P3; opt. X1 P1 and X1 P2 via BusAdapter BA 2x RJ45
● Number of ports 3; 1. integr. + 2. via BusAdapter
● integrated switch Yes
● BusAdapter (PROFINET) Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x LC,
BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC
Protocols
● IP protocol
● PROFINET IO Controller
● PROFINET IO Device
● SIMATIC communication
● Open IE communication
● Web server
● Media redundancy
Yes; IPv4
Yes
Yes
Yes
Yes; Optionally also encrypted
Yes
Yes
PROFINET IO Controller
Services
— Isochronous mode Yes
— Direct data exchange Yes; Requirement: IRT and isochronous mode (MRPD optional)
— IRT Yes
— PROFIenergy Yes; per user program
— Prioritized startup Yes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max. 128; In total, up to 512 distributed I/O devices can be connected via AS-i,
PROFIBUS or PROFINET
— Of which IO devices with IRT, max. 64
— Number of connectable IO Devices for RT, max. 128
— of which in line, max. 128
— Number of IO Devices that can be simultaneously
activated/deactivated, max.
8; in total across all interfaces
— Number of IO Devices per tool, max. 8
— Updating times The minimum value of the update time also depends on communication share
set for PROFINET IO, on the number of IO devices, and on the quantity of
configured user data
— PROFINET Security Class 1
Update time for IRT
— for send cycle of 250 μs 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum
update time of 500 μs of the isochronous OB is decisive
— for send cycle of 500 μs 500 μs to 8 ms
— for send cycle of 1 ms 1 ms to 16 ms
— for send cycle of 2 ms 2 ms to 32 ms
— for send cycle of 4 ms 4 ms to 64 ms
— With IRT and parameterization of “odd” send cycles Update time = set “odd” send clock (any multiple of 125 μs: 375 μs, 625 μs … 3
875 μs)
Update time for RT
— for send cycle of 250 μs 250 μs to 128 ms
— for send cycle of 500 μs 500 μs to 256 ms
— for send cycle of 1 ms 1 ms to 512 ms
— for send cycle of 2 ms 2 ms to 512 ms
— for send cycle of 4 ms 4 ms to 512 ms
PROFINET IO Device
Services
— Isochronous mode No
— IRT Yes
— PROFIenergy Yes; per user program
— Shared device Yes
— Number of IO Controllers with shared device, max. 4
— activation/deactivation of I-devices Yes; per user program
— Asset management record Yes; per user program
— PROFINET Security Class SNMP Configuration and DCP Read Only
2. Interface
Interface types
● RS 485
● Number of ports
Yes; Via CM DP module
1
Protocols
● PROFIBUS DP master
● PROFIBUS DP device
● SIMATIC communication
Yes
Yes
Yes
PROFIBUS DP master
● Number of connections, max.
● max. number of DP devices
48; Of which 4 each reserved for ES and HMI
125; In total, up to 512 distributed I/O devices can be connected via AS-i,
PROFIBUS or PROFINET
Services
— Equidistance
— Isochronous mode
— activation/deactivation of DP devices
No
No
Yes
Interface types
RJ 45 (Ethernet)
● 100 Mbps
● Autonegotiation
● Autocrossing
● Industrial Ethernet status LED
Yes
Yes
Yes
Yes
RS 485
● Transmission rate, max. 12 Mbit/s
Protocols
PROFIsafe Yes; V2.4 / V2.6
Number of connections
Number of connections, max.
● Number of connections reserved for ES/HMI/web
● Number of connections via integrated interfaces
● Number of connections per CP/CM
● Number of S7 routing paths
128; via integrated interfaces of the CPU and connected CPs / CMs
10
88
32
16
Redundancy mode
● H-Sync forwarding Yes
Media redundancy
— Media redundancy Yes; only via BusAdapter
— MRP Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager;
MRP Client
— MRP interconnection, supported Yes; as MRP ring node according to IEC 62439-2 Edition 3.0
— MRPD Yes; Requirement: IRT
— Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD
— Number of stations in the ring, max. 50
SIMATIC communication
● PG/OP communication Yes; encryption with TLS V1.3 pre-selected
● S7 routing Yes
● Data record routing Yes
● S7 communication, as server Yes
● S7 communication, as client Yes
● User data per job, max. See online help (S7 communication, user data size)
Open IE communication
● TCP/IP Yes
— Data length, max. 64 kbyte
— several passive connections per port, supported Yes
● ISO-on-TCP (RFC1006) Yes
— Data length, max. 64 kbyte
● UDP
— Data length, max. 2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicast Yes; max. 78 multicast circuits
● DHCP Yes
● DNS Yes
● SNMP Yes
● DCP Yes
● LLDP Yes
● Encryption Yes; Optional
Web server
● HTTP
● HTTPS
● web API
Yes; Standard and user pages
Yes; Standard and user pages
— Number of sessions, max. 50
— number of simultaneous HTTP calls, max.
— HTTP request body, max.
4
131 072 byte
OPC UA
● Runtime license required Yes; “Small” license required
● OPC UA Client Yes; Data Access (registered Read/Write), Method Call
— Application authentication Yes
— Security policies Available security policies: None, Basic128Rsa15, Basic256Rsa15,
Basic256Sha256
— User authentication “anonymous” or by user name & password
— Number of connections, max. 4
— Number of nodes of the client interfaces,
recommended max.
1000
— Number of elements for one call of
OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList,
max.
300
— Number of elements for one call of
OPC_UA_NameSpaceGetIndexList, max.
20
— Number of elements for one call of
OPC_UA_MethodGetHandleList, max.
100
— Number of simultaneous calls of the client
instructions for session management, per connection,
max.
1
— Number of simultaneous calls of the client
instructions for data access, per connection, max.
5
— Number of registerable nodes, max. 5000
— Number of registerable method calls of
OPC_UA_MethodCall, max.
100
— Number of inputs/outputs when calling
OPC_UA_MethodCall, max.
20
● OPC UA Server Yes; data access (read, write, subscribe), method call, alarms & condition
(A&C), custom address space, role-based access control
— Application authentication Yes
— Security policies available security policies: None, Basic128Rsa15, Basic256Rsa15,
Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss
— User authentication “anonymous” or by user name & password
— GDS support (certificate management) Yes
— Number of sessions, max. 32
— Number of accessible variables, max. 50 000
— Number of registerable nodes, max. 10 000
— Number of subscriptions per session, max. 50
— Sampling interval, min. 100 ms
— Publishing interval, min. 200 ms
— Number of server methods, max. 20; max. 20 concurrently running jobs each for asynchronous instructions
OPC_UA_ServerMethodPre and OPC_UA_ServerMethodPost
— Number of inputs/outputs per server method, max. 20
— Number of monitored items, recommended max. 4 000; for 1 s sampling interval and 1 s send interval
— Number of server interfaces, max. 10 of each “Server interfaces” / “Companion specification” type and 20 of the
type “Reference namespace
— Number of nodes for user-defined server interfaces,
max.
15 000
● Alarms and Conditions Yes
— Number of program alarms 100
— Number of alarms for system diagnostics 50
Further protocols
● MODBUS Yes; MODBUS TCP
S7 message functions
Number of login stations for message functions, max. 32
number of subscriptions, max. 250
number of tags/attributes for subscriptions, max. 2 000
Program alarms Yes
Number of configurable program messages, max. 5 000; Program messages are generated by the “Program_Alarm” block,
ProDiag or GRAPH
Number of loadable program messages in RUN, max. 5 000
Number of simultaneously active program alarms
● Number of program alarms
● Number of alarms for system diagnostics
600
100
● Number of alarms for motion technology objects 160
Test commissioning functions
Joint commission (Team Engineering) Yes; Parallel online access possible for up to 5 engineering systems
Status block Yes; Up to 8 simultaneously (in total across all ES clients)
Single step Yes
Number of breakpoints 8
Profiling Yes
Status/control
● Status/control variable Yes; without fail-safe
● Variables inputs/outputs, bit memories, DBs, peripheral I/Os (without fail-safe), times,
counters
● Number of variables, max.
— of which status variables, max. 200; per job
— of which control variables, max. 200; per job
Forcing
● Forcing
● Forcing, variables
● Number of variables, max
Yes; without fail-safe
peripheral inputs/outputs (without fail-safe)
200
Diagnostic buffer
● present
● Number of entries, max.
— of which powerfail-proof
Yes
1000
500
Traces
● Number of configurable Traces
● Memory size per trace, max.
4
512 kbyte
Interrupts/diagnostics/status information
Diagnostics indication LED
● RUN/STOP LED
● ERROR LED
● MAINT LED
● Monitoring of the supply voltage (PWR-LED)
● Connection display LINK TX/RX
Yes
Yes
Yes
Yes
Yes
Supported technology objects
Motion Control Yes; Note: The number of technology objects affects the cycle time of the PLC
program; selection guide via the TIA Selection Tool
● Number of available Motion Control resources for
technology objects
1 120
● Required Motion Control resources
— per speed-controlled axis
— per positioning axis
— per synchronous axis
— per external encoder
— per output cam
— per cam track
— per probe
40
80
160
80
20
160
40
● Positioning axis
— Number of positioning axes at motion control cycle
of 4 ms (typical value)
11
— Number of positioning axes at motion control cycle
of 8 ms (typical value)
14
Controller
● PID_Compact
● PID_3Step
● PID-Temp
Yes; Universal PID controller with integrated optimization
Yes; PID controller with integrated optimization for valves
Yes; PID controller with integrated optimization for temperature
Counting and measuring
● High-speed counter
Yes
Standards, approvals, certificates
Ecological footprint
● environmental product declaration Yes
Global warming potential
— global warming potential, (total) [CO2 eq] 83.2 kg
— global warming potential, (during production) [CO2 eq] 22.3 kg
— global warming potential, (during operation) [CO2
eq]
61.8kg
— global warming potential, (after end of life cycle)
[CO2 eq]
-0.949 kg
Highest safety class achievable in safety mode
● Performance level according to ISO 13849-1
● SIL acc. to IEC 61508
PLe
SIL 3
Probability of failure (for service life of 20 years and repair time of 100 hours)
— Low demand mode: PFDavg in accordance with
SIL3
< 2.00E-05
— High demand/continuous mode: PFH in accordance
with SIL3
< 1.00E-09
product functions / security / header
PROFINET Security Class 1
signed firmware update Yes
Secure Boot Yes
safely removing data Yes
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.
● horizontal installation, max. 60 °C
● vertical installation, min. -30 °C; No condensation
● vertical installation, max.
-30 °C; No condensation
60 °C
-30 °C; No condensation
50 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
configuration / header
configuration / programming / header
Programming language
— LAD
— FBD
— STL
— SCL
— CFC
— GRAPH
Yes; incl. failsafe
Yes; incl. failsafe
Yes
Yes
No
Yes
Know-how protection
● User program protection/password protection
● Copy protection
● Block protection
Yes
Yes
Yes
Access protection
● protection of confidential configuration data
● Protection level: Write protection
● Protection level: Read/write protection
● Protection level: Write protection for Failsafe
● Protection level: Complete protection
● User administration
● Number of users
● Number of groups
● Number of roles
Yes
Yes
Yes
Yes
Yes
Yes; device-wide and centralized
100
100
50
programming / cycle time monitoring / header
● lower limit
● upper limit
adjustable minimum cycle time
adjustable maximum cycle time
Dimensions
Width
Height
Depth
100 mm
117 mm
75 mm
Weights
Weight, approx. 265 g

Additional information

Weight 0.340 kg
Dimensions 13.3 × 13.5 × 8.2 cm