Contact Us:
sales@inosaki.com

SITOP PSU8200 24 V/40 A Stabilized Power Supply – Siemens Power Supply

$ 557.70

SKU 6EP3337-8SB00-0AY0 Category

Features

input
type of the power supply network 1-phase and 2-phase AC
supply voltage at AC Automatic selection; startup starting from Ue ≥ 90/180 V
supply voltage 120 V/230 V
input voltage 1 at AC 85 … 132 V
input voltage 2 at AC 170 … 264 V
wide range input No
buffering time for rated value of the output current in the event of
power failure minimum
25 ms
operating condition of the mains buffering at Vin = 230 V
line frequency 50/60 Hz
line frequency 45 … 65 Hz
input current
● at rated input voltage 120 V 15 A
● at rated input voltage 230 V 9 A
current limitation of inrush current at 25 °C maximum 50 A
I2t value maximum 8 A²·s
fuse protection type Yes
fuse protection type in the feeder Recommended miniature circuit breaker at 1-phase operation: 16 A
characteristic C; required at 2-phase operation: circuit breaker 2-pole
connected or circuit breaker 3RV2421-4BA10 (120 V) or 3RV2411-1JA10 (230
V)
output
voltage curve at output Controlled, isolated DC voltage
output voltage at DC rated value 24 V
output voltage
● at output 1 at DC rated value 24 V
output voltage adjustable Yes; via potentiometer
adjustable output voltage 24 … 28 V; max. 960 W
relative overall tolerance of the voltage 3 %
relative control precision of the output voltage
● on slow fluctuation of input voltage 0.1 %
● on slow fluctuation of ohm loading 0.1 %
residual ripple
● maximum 100 mV
● typical 50 mV
voltage peak
● maximum 240 mV
● typical 220 mV
display version for normal operation Green LED for 24 V OK; LED yellow for overload; LED red for short-circuit or
latching shutdown
type of signal at output Relay contact (NO contact, rating 60 V DC/ 0.3 A) for “24 V OK”
behavior of the output voltage when switching on Overshoot of Vout approx. 3 %
response delay maximum 1.5 s
voltage increase time of the output voltage
● typical 30 ms
output current
● rated value 40 A
● rated range 0 … 40 A; +60 … +70 °C: Derating 3%/K
supplied active power typical 960 W
short-term overload current
● on short-circuiting during the start-up typical 120 A
● at short-circuit during operation typical 120 A
duration of overloading capability for excess current
● on short-circuiting during the start-up 25 ms
● at short-circuit during operation 25 ms
constant overload current
● on short-circuiting during the start-up typical 60 A
bridging of equipment Yes; switchable characteristic
number of parallel-switched equipment resources for increasing
the power
2
efficiency
efficiency in percent 92 %
power loss [W]
● at rated output voltage for rated value of the output
current typical
82 W
● during no-load operation maximum 6.8 W
closed-loop control
relative control precision of the output voltage with rapid
fluctuation of the input voltage by +/- 15% typical
1 %
relative control precision of the output voltage load step of
resistive load 50/100/50 % typical
1.9 %
setting time
● load step 50 to 100% typical 2 ms
● load step 100 to 50% typical 2 ms
relative control precision of the output voltage at load step of
resistive load 10/90/10 % typical
3.8 %
setting time
● load step 10 to 90% typical 1 ms
● load step 90 to 10% typical 1 ms
● maximum 1 ms
protection and monitoring
design of the overvoltage protection < 32 V
property of the output short-circuit proof Yes
design of short-circuit protection Alternatively, constant current characteristic approx. 41 A or latching shutdown
● typical 41 A
overcurrent overload capability
● in normal operation 250% Iout rated up to 25 ms, 150% Iout rated up to 5 s/min
enduring short circuit current RMS value
● typical 41 A
display version for overload and short circuit LED yellow for “overload”, LED red for “latching shutdown” or “short-circuit”
safety
galvanic isolation between input and output Yes
galvanic isolation Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178
operating resource protection class Class I
leakage current
● maximum 0.1 mA
● typical 0.1 mA
protection class IP IP20
EMC
standard
● for emitted interference EN 55022 Class B
● for mains harmonics limitation
● for interference immunity EN 61000-6-2
standards, specifications, approvals
certificate of suitability
● CE marking Yes
● UL approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus
(CSA C22.2 No. 60950-1, UL 60950-1)
● CSA approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus
(CSA C22.2 No. 60950-1, UL 60950-1)
● EAC approval Yes
● Regulatory Compliance Mark (RCM) Yes
● NEC Class 2 No
type of certification
● BIS Yes; R-41183539
● CB-certificate Yes
MTBF at 40 °C 838 156 h
standards, specifications, approvals hazardous environments
certificate of suitability
● IECEx No
● ATEX No
● ULhazloc approval No
● cCSAus, Class 1, Division 2 No
● FM registration No
standards, specifications, approvals marine classification
shipbuilding approval Yes
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS) Yes
● French marine classification society (BV) No
● Det Norske Veritas (DNV) Yes
● Lloyds Register of Shipping (LRS) No
standards, specifications, approvals Environmental Product Declaration
Environmental Product Declaration Yes
global warming potential [CO2 eq]
● total 2 616.1 kg
● during manufacturing 48.8 kg
● during operation 2 565.8 kg
● after end of life 0.7 kg
ambient conditions
ambient temperature
● during operation -25 … +70; with natural convection
● during transport -40 … +85
● during storage -40 … +85
environmental category according to IEC 60721 Climate class 3K3, 5 … 95% no condensation
connection method
type of electrical connection screw terminal
● at input L, N, PE: 1 screw terminal each for 0.2 … 4 mm² single-core/finely stranded
● at output +, -: 2 screw terminals each for 0.5 … 10 mm²
● for auxiliary contacts 13, 14 (alarm signal): 1 screw terminal each for 0.14 … 1.5 mm²
mechanical data
width × height × depth of the enclosure 145 × 145 × 150 mm
installation width × mounting height 150 mm × 225 mm
required spacing
● top 40 mm
● bottom 40 mm
● left 0 mm
● right 0 mm
fastening method Snaps onto DIN rail EN 60715 35×15
● DIN-rail mounting Yes
● S7 rail mounting No
● wall mounting No
housing can be lined up Yes
net weight 3.1 kg
accessories
electrical accessories Buffer module, redundancy module
mechanical accessories Device identification label 20 mm × 7 mm, TI-grey 3RT2900-1SB20
further information internet links
internet link
● to website: Industry Mall https://mall.industry.siemens.com
● to web page: selection aid TIA Selection Tool https://www.siemens.com/tstcloud
● to web page: power supplies https://siemens.com/sitop
● to website: CAx-Download-Manager https://siemens.com/cax
● to website: Industry Online Support https://support.industry.siemens.com
additional information
other information Specifications at rated input voltage and ambient temperature +25 °C (unless
otherwise specified)
security information
security information Siemens provides products and solutions with industrial cybersecurity functions
that support the secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber
threats, it is necessary to implement – and continuously maintain – a holistic,
state-of-the-art industrial cybersecurity concept. Siemens’ products and
solutions constitute one element of such a concept. Customers are responsible
for preventing unauthorized access to their plants, systems, machines and
networks. Such systems, machines and components should only be connected
to an enterprise network or the internet if and to the extent such a connection is
necessary and only when appropriate security measures (e.g. firewalls and/or
network segmentation) are in place. For additional information on industrial
cybersecurity measures that may be implemented, please visit
www.siemens.com/cybersecurity-industry. Siemens’ products and solutions
undergo continuous development to make them more secure. Siemens strongly
recommends that product updates are applied as soon as they are available
and that the latest product versions are used. Use of product versions that are
no longer supported, and failure to apply the latest updates may increase
customer’s exposure to cyber threats. To stay informed about product updates,
subscribe to the Siemens Industrial Cybersecurity RSS Feed under
https://www.siemens.com/cert. (V4.7)

Additional information

Weight 3.1 kg
Dimensions 22.5 × 22 × 18.50 cm

Related Products

SICK_sensor_Photoelectric_sensor_W4S-3 Inox Hygiene_WTB4S-3P5232H
PEPPERLFUCHS_Sensor-Actuator Cables_V1-G-2M-PVC-V1-G
QS18VN6WQ5
SICK_Mounting_systems_BEF-EA-CM30
IDS_Camera_U3-3132ACP Rev.1
TL-QN