Sale!

Festo 8134891 Pressure Sensor, −1 to 10 bar, PNP/NPN

Original price was: USD 103.22.Current price is: USD 89.18.

Piezoresistive sensor with threshold, window and auto-difference monitoring, illuminated LCD, R1/8 and M5 pressure connections, and 15–30 V DC supply.

SKU Festo-8134891 Category
Festo Pressure Sensors And Vacuum Sensors

Festo SPAN-B11R-R18M-PN-PN-L1 Pressure Sensor

BrandFesto
Model IdentifierSPAN-B11R-R18M-PN-PN-L1
Official Part Number8134891

Technical Overview

The Festo SPAN-B11R-R18M-PN-PN-L1 measures relative pressure from −1 to 10 bar using a piezoresistive sensor, covering both vacuum and positive-pressure monitoring. Two outputs can be configured as PNP or NPN and normally closed or normally open, with threshold, window-comparator and auto-difference monitoring functions. An illuminated LCD, teach-in and front buttons support local setup, while PIN-code protection restricts changes. The unit operates from 15–30 V DC through a four-contact L1J plug connection and provides male R1/8 and female M5 pneumatic interfaces. Thread, front-panel or bracket mounting accommodates installation in a protected IP40 location.

−1 to 10 bar relative-pressure sensor with two switchable PNP/NPN outputs, illuminated LCD and R1/8/M5 pneumatic connections.

Key Features

  • Piezoresistive relative-pressure range of −1 to 10 bar
  • ±1.5% FS accuracy and ±0.3% FS repetition accuracy
  • Two PNP or two NPN switching outputs; NC/NO selection
  • Threshold comparator, window comparator and auto-difference monitoring
  • 100 mA maximum output current with short-circuit protection
  • Illuminated LCD, teach-in, front buttons and PIN-code protection
  • Male R1/8 and female M5 pneumatic connections
  • 15–30 V DC supply with four-contact L1J electrical plug
  • Front-panel, threaded or wall/surface-bracket mounting
  • IP40 protection; 0–50 °C ambient and media temperature

Monitor vacuum and positive pressure with configurable threshold, window and pressure-difference switching in one locally adjustable sensor.

Technical Specification Matrix

ParameterValue
ApprovalRCM; c UL us - Listed (Oil)
CE mark (see declaration of conformity)To EU EMC Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions
Certificate issuing authorityUL E322346
Note on materialsRoHS compliant
Measured variableRelative pressure
Measurement methodPiezoresistive pressure sensor
Start value for pressure measuring range-0.1 MPa; -1 bar; -14.5 psi
End value for pressure measuring range1 MPa; 10 bar; 145 psi
Max. overload pressure15 bar
Overload pressure1.5 MPa; 15 bar; 217.5 psi
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]; Inert gas
Note on operating and pilot mediumLubricated operation possible
Media temperature0 °C...50 °C
Ambient temperature0 °C...50 °C
Accuracy in ± % FS1.5 %FS
Repetition accuracy in ± %FS0.3 %FS
Temperature coefficient in ± %FS/K0.05 %FS/K
Switching output2 x PNP or 2 x NPN, switchable
Switching functionWindow comparator; Threshold value comparator; Auto difference monitoring
Switching element functionNC or NO, switchable
Max. output current100 mA
Short circuit current ratingYes
Operational voltage range DC15 V...30 V
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlug
Electrical connection 1, connector systemPlug pattern L1J
Electrical connection 1, number of connections/cores4
Type of mountingFront panel mounting; With thread; Via wall/surface bracket
Mounting positionAny
Pneumatic connectionMale thread R1/8; Female thread M5
Physical Weight (kg)0.046
Material housingReinforced PA
Material in contact with the mediumFluoro rubber; High-alloy stainless steel
Display typeIlluminated LCD
Displayable unitsMPa; bar; inH2O; inHg; kPa; kgf/cm²; mbar; mmHg; psi
Setting optionsTeach-in; Via display and buttons
Protection against tamperingPIN code
Setting range threshold value0 %...100 %
Setting range hysteresis0 %...90 %
Degree of protectionIP40
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Suitability for the production of Li-ion batteriesSuitable for battery production with reduced Cu/Zn/Ni values (F1a)
Cleanroom suitability, measured according to ISO 14644-14Class 4 according to ISO 14644-1

Industrial Applications

1. Vacuum Pickup Readiness Signal

A suction handling station needs an electrical indication that the measured vacuum has reached the configured pickup threshold. This sensor's −1 to 10 bar relative range includes the vacuum operating region, and its PNP/NPN selection matches different controller input types. The local LCD and teach-in function assist setting the switching level at the handling station.

Problem Solved

A configurable vacuum threshold turns the measured pressure condition into a controller input, supporting pickup-sequence decisions without depending on a technician's local gauge reading.

Vacuum range to −1 bar PNP/NPN Teach-in

2. Regulated-Air Pressure Window Monitoring

An assembly fixture requires its regulated air supply to remain inside a defined operating band. The sensor's window-comparator function evaluates the measured pressure against a configured window rather than a single limit. Its illuminated display provides a local reading during regulator adjustment, while selectable output polarity connects the resulting condition to the machine's input circuit.

Problem Solved

Window comparison identifies when pressure leaves the selected band, giving the controller a useful process-condition signal while the technician retains a local pressure display.

Window comparator Illuminated LCD Up to 10 bar

3. Pressure-Change Monitoring in an Isolated Circuit

A pneumatic test fixture isolates a charged volume and monitors whether its pressure changes during a defined machine sequence. The sensor provides an auto-difference monitoring mode and ±0.3% FS repetition accuracy, allowing the controller to use a pressure-change signal. Isolation, timing and acceptance criteria remain functions of the surrounding test equipment rather than an assumed feature of the sensor.

Problem Solved

Auto-difference monitoring converts a pressure change into a switching condition, supporting detection of an unwanted change in a controlled isolated-volume sequence without manual observation.

Auto-difference monitoring ±0.3% FS repeatability 2 outputs
Select your currency