1. Compressed-Air Branch Readiness
A low-pressure pneumatic workstation needs a pressure-ready signal before starting a clamping or handling sequence. Installed on the branch through its G1/4 female connection, the sensor measures supply pressure over 0–2 bar. Programmable PNP switching lets the controller distinguish the required pressure condition, while the local display helps operators see the measured value during setup.
Problem Solved
Pressure-dependent switching gives the controller a direct branch-readiness signal, helping prevent a machine sequence from starting when the measured air pressure is below its programmed requirement.
0–2 bar
2 PNP outputs
G1/4 female
2. Liquid-Pump Pressure Supervision
A circulation or transfer skid needs electrical pressure feedback from a liquid line compatible with high-alloy stainless steel. The piezoresistive element measures line pressure, and two programmable PNP outputs can represent separate operating thresholds. IP65/IP67 protection supports installation around the skid, with media temperatures from −20 to 85 °C within the specified measuring and overload limits.
Problem Solved
Two configurable switching signals communicate separate pressure conditions from one wetted connection, helping the skid controller detect departure from its intended operating pressure without relying solely on local observation.
Stainless wetted material
−20 to 85 °C media
IP65/IP67
3. Pressure-Test Setpoint Indication
A pressure-test fixture needs to indicate whether its pressurised circuit has reached a selected test condition. The sensor's ±1% full-scale accuracy and ±0.15% full-scale repetition accuracy provide defined measurement characteristics for setting those thresholds. Local buttons and the four-place LED display support recipe setup, while PIN protection helps retain the selected settings between test batches.
Problem Solved
Programmable pressure thresholds translate the fixture's measured condition into controller signals, while the display and PIN-protected settings help operators maintain a consistent test setpoint between batches.
±1% FS accuracy
±0.15% FS repetition
PIN protection