Festo 8022742 Pressure Sensor, 0–2 bar, 2 PNP, G1/4

Original price was: USD 310.70.Current price is: USD 267.28.

Piezoresistive pressure sensor with ±1% FS accuracy, two 250 mA PNP outputs, G1/4 female port, four-pin M12 connection and IP65/IP67 protection.

SKU Festo-8022742 Category
Festo Pressure Sensors And Vacuum Sensors

Festo SPAW-P2R-G14F-2P-M12 Pressure Sensor

BrandFesto
Model IdentifierSPAW-P2R-G14F-2P-M12
Official Part Number8022742

Technical Overview

The Festo SPAW-P2R-G14F-2P-M12 measures relative pressure from 0 to 2 bar using a piezoresistive sensing element. Two freely programmable PNP switching outputs provide pressure-dependent signals, with ±1% full-scale accuracy, ±0.15% full-scale repetition accuracy and a 3 ms rise time. The G1/4 female process connection and high-alloy stainless-steel wetted material support compatible compressed-air, gaseous and liquid media at −20 to 85 °C. A four-place alphanumeric LED display, local buttons and PIN protection support setup and monitoring, while the four-pin A-coded M12 interface supplies the 15–35 V DC electronics within an IP65/IP67 enclosure.

0–2 bar relative-pressure sensor with piezoresistive sensing, two programmable PNP outputs, G1/4 female connection and IP65/IP67 protection.

Key Features

  • 0–2 bar relative-pressure measuring range and 4 bar overload pressure
  • Piezoresistive sensing with ±1% FS accuracy
  • ±0.15% FS repetition accuracy and 3 ms rise time
  • Two freely programmable PNP switching outputs, up to 250 mA
  • 15–35 V DC operating range with reverse-polarity protection
  • G1/4 female process connection and high-alloy stainless-steel wetted material
  • Four-pin A-coded M12x1 electrical plug with screw lock
  • Four-place alphanumeric LED display, local buttons and PIN protection
  • IP65/IP67 protection and CRC 4 corrosion-resistance classification
  • −20 to 85 °C media range, 0 to 80 °C ambient range and 230 g product weight

Monitor compatible gas or liquid pressure with two programmable PNP outputs and a locally readable 0–2 bar piezoresistive sensor.

Technical Specification Matrix

ParameterValue
ApprovalRCM; c UL us - Listed (Oil)
CE mark (see declaration of conformity)To EU EMC Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions
Note on materialsRoHS compliant
Measured variableRelative pressure
Measurement methodPiezoresistive pressure sensor
Start value for pressure measuring range0 MPa; 0 bar; 0 psi
End value for pressure measuring range0.2 MPa; 2 bar; 29 psi
Overload pressure0.4 MPa; 4 bar; 58 psi
Operating mediumCompressed air to ISO 8573-1:2010 [-:-:-]; Liquid media; Gaseous media
Media temperature-20 °C...85 °C
Ambient temperature0 °C...80 °C
Accuracy in ± % FS1 %FS
Repetition accuracy in ± %FS0.15 %FS
Switching output2xPNP
Switching functionFreely programmable
Switching element functionSwitchable
Max. output current250 mA
Rise time3 ms
Short circuit current ratingYes
Operational voltage range DC15 V...35 V
Reverse polarity protectionFor operating voltage
Electrical connection 1, connection typePlug
Electrical connection 1, connector systemM12x1, A-coded to EN 61076-2-101
Electrical connection 1, number of connections/cores4
Electrical connection 1, type of mountingScrew-type lock; Not rotatable
Electrical connection 1, compatible type of mountingCompatible with rotatable screw-type lock
Type of mountingWith female thread; With accessories
Mounting positionAny
Pneumatic connectionFemale thread G1/4
Physical Weight (kg)0.23
Material housingABS; High-alloy stainless steel
Material in contact with the mediumHigh-alloy stainless steel
Display type4-place alphanumeric; LED indicator
Displayable unitsMPa; bar; kPa; kg/cm²; psi
Switching status indicationLED red
Setting optionsVia display and buttons
Protection against tamperingPIN code
Setting range threshold value0.5 %...100 %
Setting range hysteresis0.5 %...99.5 %
Degree of protectionIP65; IP67
Corrosion resistance class CRC4 - Very high corrosion stress
LABS (PWIS) conformityVDMA24364 zone III

Industrial Applications

1. Compressed-Air Branch Readiness

A low-pressure pneumatic workstation needs a pressure-ready signal before starting a clamping or handling sequence. Installed on the branch through its G1/4 female connection, the sensor measures supply pressure over 0–2 bar. Programmable PNP switching lets the controller distinguish the required pressure condition, while the local display helps operators see the measured value during setup.

Problem Solved

Pressure-dependent switching gives the controller a direct branch-readiness signal, helping prevent a machine sequence from starting when the measured air pressure is below its programmed requirement.

0–2 bar 2 PNP outputs G1/4 female

2. Liquid-Pump Pressure Supervision

A circulation or transfer skid needs electrical pressure feedback from a liquid line compatible with high-alloy stainless steel. The piezoresistive element measures line pressure, and two programmable PNP outputs can represent separate operating thresholds. IP65/IP67 protection supports installation around the skid, with media temperatures from −20 to 85 °C within the specified measuring and overload limits.

Problem Solved

Two configurable switching signals communicate separate pressure conditions from one wetted connection, helping the skid controller detect departure from its intended operating pressure without relying solely on local observation.

Stainless wetted material −20 to 85 °C media IP65/IP67

3. Pressure-Test Setpoint Indication

A pressure-test fixture needs to indicate whether its pressurised circuit has reached a selected test condition. The sensor's ±1% full-scale accuracy and ±0.15% full-scale repetition accuracy provide defined measurement characteristics for setting those thresholds. Local buttons and the four-place LED display support recipe setup, while PIN protection helps retain the selected settings between test batches.

Problem Solved

Programmable pressure thresholds translate the fixture's measured condition into controller signals, while the display and PIN-protected settings help operators maintain a consistent test setpoint between batches.

±1% FS accuracy ±0.15% FS repetition PIN protection
Select your currency