Skip to content

Contact Us:
sales@inosaki.com

SICK 1073211 STR1-SASF0AC5 RFID Safety Switch with Actuator

SICK 1073211 STR1-SASF0AC5 RFID Safety Switch with Actuator

USD 178.88

STR1-SASF0AC5 includes sensor and actuator, permanently coded RFID, two OSSDs, 10 mm frontal assured switch-on distance and a 0.2 m M12 connection.

SKU: SICK-1073211 Category:
SICK Safety Switches

SICK STR1-SASF0AC5 RFID Non-contact Safety Switch

BrandSICK
Model IdentifierSTR1-SASF0AC5
Official Part Number1073211

Technical Overview

The SICK STR1-SASF0AC5 is a non-contact RFID safety switch supplied as a sensor-with-actuator system. Permanently coded operation, high coding level and two self-monitoring OSSDs support guard-position evaluation by an external safety system. Frontal alignment provides a 10 mm assured switch-on distance and 25 mm assured switch-off distance; the side-surface switch-on distance is 6 mm. An auxiliary output switches complementarily to the OSSDs for ordinary diagnostics. The device supports safe series connection through Flexi Loop with diagnostics. Its 0.2 m PVC cable ends in a five-pin M12 plug, with a 24 V DC supply and IP67/IP69K VISTAL housing. The −30 °C lower operating limit applies to serial series 1825**** or higher.

Permanently coded RFID sensor-with-actuator system with two OSSDs, 10 mm frontal assured switch-on distance, complementary AUX and 0.2 m five-pin M12 connection.

Key Features

  • Sensor with standard actuator; RFID non-contact detection
  • Permanently coded; high coding level; type 4, EN ISO 14119
  • Two self-monitoring OSSDs; one complementary non-safe AUX output
  • Frontal assured switch-on 10 mm; assured switch-off 25 mm
  • Side-surface assured switch-on 6 mm; three active sensor surfaces and five actuation directions
  • SIL 3; category 4; PL e; 20-year mission time
  • Safe series connection through Flexi Loop with diagnostics
  • 0.2 m PVC cable with five-pin M12 male plug; 24 V DC, 19.2–28.8 V
  • VISTAL housing; IP67/IP69K; local diagnostic/status LEDs
  • Operation −30 to +70 °C for serial series 1825**** or higher; earlier series −10 to +70 °C

Report the presented guard actuator through two OSSDs, with separate complementary diagnostics and alignment-specific assured switching distances.

Technical Specification Matrix

ParameterValue
System partSensor with actuator
Sensor principleRFID
CodingPermanently coded; high coding level, EN ISO 14119
Device typeType 4, EN ISO 14119
Safety outputsTwo self-monitoring semiconductor OSSDs
Auxiliary outputOne; complementary switching behavior to OSSDs; not safe
Frontal assured switch-on distance Sao10 mm; frontal sensor/actuator alignment; observe serial-specific operating temperature
Frontal assured switch-off distance Sar25 mm; frontal sensor/actuator alignment
Side-surface assured switch-on distance Sao6 mm with standard actuator; follow response-range diagram
Parallel approachObserve border areas; typical minimum 6 mm distance during lateral movement toward front sensor surface
Active sensor surfacesThree: top, left side and right side
Actuation directionsFive; follow manufacturer alignment instructions
Safety integrity levelSIL 3, IEC 61508
CategoryCategory 4, EN ISO 13849
Performance levelPL e, EN ISO 13849
PFHD5.1 × 10⁻⁹ per hour
Mission time20 years, EN ISO 13849
Fault safe stateAt least one OSSD OFF
Series connectionWith Flexi Loop, with diagnostics
Connection0.2 m cable with M12 five-pin male plug
Pin assignment1=24 V DC supply; 2=OSSD1; 3=0 V; 4=OSSD2; 5=AUX, not safe
Maximum connecting cable length≤200 m
Cable materialPVC; copper conductors
Cable diameter5.5 mm
Conductor cross-section0.12 mm²
Bend radius, fixed>8 × cable diameter
Bend radius, moving>12 × cable diameter
Coupling nut materialNickel-plated zinc die-cast
IndicationLED diagnostics and status
Power supply24 V DC, 19.2–28.8 V DC
Current consumption50 mA
Output current≤100 mA
Response time40 ms; downstream switches increase system response time in safe series connection
Release time100 ms on approach to enable zone; observe series-connection timing
Risk time80 ms fault-detection time; observe series-connection timing
Switch-on time2.5 s for one sensor after supply application; in safe series connection add 0.1 s per sensor; add 0.5 s per taught-in actuator for permanently coded sensors
Protection classIII, IEC 61140
cULus classificationClass 2
Housing materialVISTAL
IP ratingIP67, IEC 60529; IP69K, ISO 20653
Operating temperature−30 to +70 °C only for serial numbers beginning with 1825**** or higher; other serial numbers −10 to +70 °C
Storage temperature−30 to +70 °C
Vibration resistance10–55 Hz, 1 mm; IEC 60068-2-6
Shock resistance30 g, 11 ms; IEC 60068-2-27
EMCEN IEC 61326-3-1; EN IEC 60947-5-2; EN IEC 60947-5-3; EN 300330 V2.1.1

Industrial Applications

1. Evaluating a closed machine guard without contact

A movable guard can carry the supplied standard actuator toward the installed RFID sensor. External safety evaluation reads the two OSSDs to evaluate the presented actuator condition. Frontal alignment uses the 10 mm assured switch-on and 25 mm assured switch-off distances, with commissioning checking the actual alignment, approach geometry, response timing and the installed unit’s serial-specific temperature range.

Problem Solved

A contactless actuator-position condition gives the external safety system a reference for a presented guard, using permanently coded RFID identification and alignment-specific assured switching distances.

Guard position Permanent coding Dual OSSDs

2. Collecting several guard conditions through Flexi Loop

A machine with several guarded access points can connect compatible STR1 switches through the documented Flexi Loop arrangement with diagnostics. Each switch reports its local actuator condition into the external safety design. Commissioning accounts for the increase in system timing from downstream switches and the startup allowances for sensors and taught-in actuators, alongside the alignment of every installed actuator.

Problem Solved

A documented Flexi Loop arrangement supports external evaluation of several guard conditions with diagnostics, while the installed protective function accounts for accumulated response and startup behavior.

Several guards Flexi Loop Timing allowances

3. Displaying actuator status during guard alignment

During mechanical alignment, ordinary machine logic can read the complementary auxiliary output and use the local diagnostic/status LEDs to review actuator presentation. The operator compares that indication with the installed approach geometry and the selected active sensor surface. The two dedicated OSSDs remain connected to the external safety evaluation, while the auxiliary output serves the ordinary diagnostic display.

Problem Solved

Separate complementary status feedback helps personnel inspect guard alignment and actuator presentation, using an ordinary diagnostic signal alongside the dedicated outputs evaluated by the external safety system.

Guard alignment Complementary AUX Local indication