Feed-through terminal block, nom. voltage: 800 V, nominal current: 24 A, connection method: Screw connection, number of connections: 2, cross section: 0.5 mm² – 4 mm², AWG: 20 – 12, width: 6.2 mm, color: blue, mounting type: NS 35/7,5, NS 35/15, NS 32
| Article Number | 3057720 |
|---|---|
| Number of levels | 1 |
| Number of connections | 2 |
| Potentials | 1 |
| Nominal cross section | 2.5 mm² |
| Color | blue |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
| Mounting type | NS 35/7,5 |
| Rated surge voltage | 8 kV |
| Degree of pollution | 3 |
| Overvoltage category | III |
| Insulating material group | I |
| Maximum load current | 24 A (at 2.5 mm²) |
| Nominal current IN | 24 A |
| Nominal voltage UN | 800 V |
| Open side panel | Yes |
| Width | 6.2 mm |
|---|---|
| End cover width | 1.5 mm |
| Length | 42.5 mm |
| Height NS 35/7,5 | 42 mm |
| Height NS 35/15 | 49.5 mm |
| Height NS 32 | 47 mm |
| Connection method | Screw connection |
|---|---|
| Screw thread | M2,5 |
| Stripping length | 7 mm |
| Tightening torque, min | 0.4 Nm |
| Tightening torque max | 0.5 Nm |
| Connection in acc. with standard | IEC 60947-7-1 |
| Conductor cross section solid min. | 0.5 mm² |
| Conductor cross section solid max. | 4 mm² |
| Conductor cross section AWG min. | 20 |
| Conductor cross section AWG max. | 12 |
| Conductor cross section flexible min. | 0.5 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Min. AWG conductor cross section, flexible | 20 |
| Max. AWG conductor cross section, flexible | 14 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 2.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 1 mm² |
| Cross section with insertion bridge, solid max. | 1.5 mm² |
| Cross section with insertion bridge, stranded max. | 1.5 mm² |
| 2 conductors with same cross section, solid min. | 0.5 mm² |
| 2 conductors with same cross section, solid max. | 1.5 mm² |
| 2 conductors with same cross section, stranded min. | 0.5 mm² |
| 2 conductors with same cross section, stranded max. | 1.5 mm² |
| Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum | 0.5 mm² |
| Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum | 1 mm² |
| Internal cylindrical gage | A3 |
| Operating temperature | -60 °C … 105 °C (max. short-term operating temperature 125°C) |
|---|---|
| Ambient temperature (storage/transport) | -25 °C … 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Permissible humidity (storage/transport) | 30 % … 70 % |
| Ambient temperature (assembly) | -5 °C … 70 °C |
| Ambient temperature (actuation) | -5 °C … 70 °C |
| Connection in acc. with standard | UL |
|---|---|
| IEC 60947-7-1 | |
| Flammability rating according to UL 94 | V0 |
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |