SICK 6026136 UE410-MU3T5 Flexi Classic Safety Main Module

USD 479.96

UE410-MU3T5 provides four safety inputs, four switching inputs, four safety outputs, two test outputs and 0–5 s Q3/Q4 delay, with rotary configuration.

SKU SICK-6026136 Category
SICK Safety Controllers

SICK UE410-MU3T5 Flexi Classic Safety Main Module

BrandSICK
Model IdentifierUE410-MU3T5
Official Part Number6026136

Technical Overview

The SICK UE410-MU3T5 is a Flexi Classic safety main module configured by rotary switch. It provides four safety inputs, four switching inputs, four safety outputs and two test outputs, with a 0–5 s delay for Q3/Q4. Functions include configurable manual or automatic restart interlock, external device monitoring, AND/OR operation, bypass and muting with zero or two muting sensors. The stated component ratings are SIL 3, category 4 and PL e; achieved machine performance depends on the complete validated design. Plug-in screw-type terminals and LEDs support connection and indication. The 24 V DC PELV/SELV supply operates within 19.2–30 V and requires current limited to 4 A maximum.

Rotary-configured Flexi Classic safety main module with four safety inputs, four safety outputs, two test outputs and 0–5 s Q3/Q4 delay.

Key Features

  • Flexi Classic safety main module; rotary-switch configuration
  • Four safety inputs and four switching inputs
  • Four safety outputs and two test outputs
  • Q3/Q4 output delay adjustable from 0–5 s
  • SIL 3, category 4 and PL e component ratings; PFHD 2.5 × 10⁻⁹ per hour
  • Manual/automatic restart interlock; external device monitoring
  • AND/OR, bypass and muting functions; zero or two muting sensors
  • Plug-in screw-type terminals and LED indication
  • 24 V DC nominal, 19.2–30 V PELV/SELV; supply current limited to maximum 4 A
  • Housing IP40; terminals IP20; −25 to +55 °C operation

Configure safety inputs, external device monitoring and delayed Q3/Q4 outputs in a Flexi Classic main module for the validated machine sequence.

Technical Specification Matrix

ParameterValue
Module typeFlexi Classic safety main module
ConfigurationRotary switches
Safety inputs4
Switching inputs4
Safety outputs4
Test outputs2
Output delayQ3/Q4: 0–5 s
Restart interlockManual / automatic, configurable
External device monitoringEDM provided
Logic functionsAND and OR
Additional functionsBypass and muting
Muting sensors0 or 2
Safety integrity levelSIL 3, IEC 61508
Category4, EN ISO 13849
Performance levelPL e, EN ISO 13849
PFHD2.5 × 10⁻⁹ per hour, EN ISO 13849
Mission time20 years, EN ISO 13849
System integrationMain module for a configured Flexi Classic safety-control arrangement
ConnectionPlug-in screw-type terminals
DisplayLEDs
Protection classIII, EN 61140
Supply typePELV or SELV; power supply current limited to maximum 4 A by the supply or a fuse
Power supply24 V DC nominal; 19.2–30 V DC
Residual ripple≤10%
Power consumption≤3 W DC
Internal power consumption≤3 W DC
Housing IP ratingIP40, EN 60529
Terminal IP ratingIP20, EN 60529
Operating temperature−25 to +55 °C
Storage temperature−25 to +70 °C
Air humidity≤95%, non-condensing
Climate conditionsEN 61131-2; +55 °C operating ambient and 95% relative humidity
EMCClass A; EN 61000-6-2 and EN 55011
Vibration resistance5 g RMS, 5–500 Hz; EN 60068-2-64
Switch-on time≤60 s
Physical Weight (kg)0.18
Dimensions L x W x H (cm)12.08 x 2.25 x 9.65

Industrial Applications

1. Evaluating safety inputs in a machine control arrangement

A machine designer can use the main module to evaluate four safety inputs and provide configured safety outputs within a Flexi Classic arrangement. Rotary-switch configuration establishes the intended logic and restart behavior. Commissioning validates the connected devices, input combinations, output response and external device monitoring against the complete machine safety requirement.

Problem Solved

Configured safety-input evaluation gives the control design a basis for responding to connected protective devices, with restart and output behavior established for the validated machine arrangement.

Safety input evaluation Main module Rotary configuration

2. Coordinating delayed outputs in a stopping sequence

A machine stopping sequence can assign the Q3/Q4 outputs a delay within the specified 0–5 s range when that behavior is required by the validated safety design. The configured main module evaluates its inputs and controls connected output devices. Commissioning checks the actual delay, external device monitoring, stopping behavior and restart conditions with the installed equipment.

Problem Solved

Configurable delayed outputs help implement an engineered stopping sequence, while selected timing and external device behavior are verified against the complete machine safety requirement.

Delayed outputs Stopping sequence External device monitoring

3. Evaluating a material-transfer muting configuration

A material-transfer station can use the main module’s muting function within a configured Flexi Classic arrangement, with the documented zero-or-two muting-sensor option selected for the design. The system designer establishes sensor placement, signal evaluation and the permitted transfer condition. Commissioning validates the resulting behavior, including foreseeable access conditions and restoration of the protective function, for the complete machine installation.

Problem Solved

Muting functionality provides a basis for configured material-transfer logic, with the sensor arrangement and restoration of protective behavior established by the validated machine application.

Muting configuration Material transfer Protective behavior
Select your currency