| Nominal size, Laval nozzle | 0.7 mm |
| Mounting grid pitch | 16 mm |
| Silencer design | Open |
| Mounting position | Any |
| Ejector characteristic | High vacuum; Standard |
| Integrated function | Pressure sensor; Open silencer |
| Design | T-shape |
| Short circuit current rating | Pulsed |
| Measured variable | Relative pressure |
| Measuring principle | Piezoresistive |
| Measurement method | relatively |
| Switching element function | N/O contact |
| Switching function | Threshold value comparator; Threshold value with fixed hysteresis |
| Reverse polarity protection | For all electrical connections |
| Display type | LED |
| Setting range threshold value | -100 kPa...0 kPa; -1 bar...0 bar; -14.5 psi...0 psi |
| Setting options | Teach-in |
| Switching status indication | LED |
| Operating pressure for max. suction flow rate | 0.3 MPa; 3 bar; 43.5 psi |
| Operating pressure | 0.1 MPa...0.8 MPa; 1 bar...8 bar; 14.5 psi...116 psi |
| Operating pressure for max. vacuum | 0.44 MPa; 4.4 bar; 63.8 psi |
| Max. vacuum | 92 % |
| Nominal operating pressure | 0.6 MPa; 6 bar; 87 psi |
| Max. suction flow rate against atmosphere | 16.2 l/min |
| Switch-off time | 4 ms |
| Switch-on time | 4 ms |
| Operational voltage range DC | 15 V...30 V |
| Inductive protective circuit | Adapted to MZ, MY, ME coils |
| Max. output current | 100 mA |
| Off-state current | 0.3 mA |
| Residual ripple | 10% |
| Switching output | PNP |
| Voltage drop | 1.5 V |
| Overload protection | Available |
| Approval | RCM |
| KC mark | KC-EMV |
| CE mark (see declaration of conformity) | To EU EMC Directive |
| UKCA marking (see declaration of conformity) | To UK instructions for EMC |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation not possible |
| Corrosion resistance class CRC | 1 - Low corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Media temperature | 0 °C...60 °C |
| Recommended cleaning/purification | Soapy water |
| Sound pressure level at nominal operating pressure | 66 dB(A) |
| Degree of protection | IP40 |
| Ambient temperature | 0 °C...50 °C |
| Max. tightening torque | 0.6 Nm |
| Pressure measuring range | -100 kPa...0 kPa; -1 bar...0 bar; -14.5 psi...0 psi |
| Physical Weight (kg) | 0.036 |
| Accuracy in ± % FS | 1.5 %FS |
| Hysteresis in ± %FS | 2 %FS |
| Long-term drift | ±0.5 % FS max. |
| Temperature cooefficient of switching point | 0.05 %/K |
| Electrical connection | 3-pin; M8 |
| Type of mounting | With through-hole |
| Pneumatic connection, port 1 | QS-6 |
| Pneumatic connection, port 3 | Open silencer |
| Vacuum connection | QS-6 |
| Material seals | NBR |
| Material receiver nozzle | POM |
| Material housing | Reinforced POM |
| Material fibre-optic | Makrolon® |
| Material silencer | PE |
| Material connector housing | Brass; PA; Chrome-plated and nickel-plated |
| Material transmitter nozzle | Wrought aluminium alloy |
| Material keypad | POM |
| Material fitting | Brass; nickel-plated |