SICK 6026221 NPN Through-beam Photoelectric Sensor

USD 247.52

VS/VE12-2N132 offers 0–4 m through-beam sensing, 880 nm LED light, selectable NPN light/dark switching, 2 m PVC cable and IP67 protection.

SKU SICK-6026221 Category
SICK V12-2

SICK VS/VE12-2N132 Through-beam Photoelectric Sensor

BrandSICK
Model IdentifierVS/VE12-2N132
Official Part Number6026221

Technical Overview

The SICK VS/VE12-2N132 is a cylindrical through-beam photoelectric sensor with separate sender and receiver units. Its 880 nm infrared LED supports a 0–4 m sensing range and 0–5 m maximum range, producing a 100 mm spot at 4 m. An NPN receiver output uses the L/D control wire for light/dark selection; no sensitivity adjustment is provided. Response is up to 2 ms with resistive load, with 250 Hz switching at a 1:1 light/dark ratio. The M12 × 1 threaded housings combine nickel-plated brass and PA with PMMA optics, IP67 protection and PVC cable connections. Operation extends from −25 to +70 °C on a 10–30 V DC supply.

Through-beam sensor with 0–4 m sensing, 880 nm infrared LED, selectable NPN light/dark switching and PVC cable connections.

Key Features

  • Separate sender and receiver for through-beam detection
  • 0–4 m sensing; 0–5 m maximum range
  • 880 nm infrared LED; Ø100 mm spot at 4 m
  • NPN output; light/dark selection through L/D connection
  • No sensitivity adjustment; maximum output current ≤100 mA
  • ≤2 ms response; 250 Hz switching under stated load and light/dark conditions
  • 10–30 V DC; 20 mA consumption without load
  • 2 m PVC cable connection; receiver with four wires
  • M12 × 1 threaded nickel-plated brass/PA housing; PMMA optics
  • IP67 protection; −25 to +70 °C operation

Detect beam interruption across a machine opening with separate infrared sender and receiver units and selectable NPN switching.

Technical Specification Matrix

ParameterValue
Functional principleThrough-beam photoelectric sensor; separate sender and receiver
Sensing range0–4 m
Maximum sensing range0–5 m
Light sourceInfrared LED
Wavelength880 nm
Light spot sizeØ100 mm at 4 m
Angle of dispersionApprox. 1.4°
LED service lifeAverage 100,000 h at +25 °C
AdjustmentNone
Digital outputNPN switching output; maximum current ≤100 mA
Switching modeLight/dark switching, selectable via L/D control connection
Response time≤2 ms signal transit time with resistive load
Switching frequency250 Hz at 1:1 light/dark ratio
Power supply10–30 V DC, limit values
Residual ripple±10%; remain within supply tolerances
Current consumption20 mA without load
Protection classIII
Circuit protectionA: supply reverse-polarity protection; B: inputs and output reverse-polarity protection; C: interference suppression; D: outputs overcurrent and short-circuit protection
Housing designCylindrical, M12 × 1 threaded housing
Housing materialNickel-plated brass / PA
Optics materialPMMA plastic
Connection2 m PVC cable; receiver four-wire connection; do not bend cable below 0 °C
Pin assignmentSender: BN=L+, BU=M; receiver: BN=L+, BU=M, BK=Q, WH=L/D (CD-058)
IP ratingIP67
Operating temperature−25 to +70 °C
Storage temperature−25 to +70 °C
Conductor cross-section0.14 mm²
Cable diameterØ3.75 mm

Industrial Applications

1. Counting separated opaque parts at a small chute

A small-parts chute can place the sender and receiver on opposite sides of a clear opening within the 0–4 m sensing range. Each separated opaque part interrupts the beam as it falls. External counting logic evaluates the NPN output, with the part profile, spacing and transit speed checked against the beam geometry and switching limits.

Problem Solved

A discrete passage reference helps external counting logic register separated parts at a narrow chute without depending on light returned from each part surface.

Small-parts chute Beam interruption External counting

2. Confirming a carrier at a compact transfer stop

A transfer station can align the sender and receiver across an opaque feature of a carrier at its seated position. The 0–4 m sensing range supports a short optical crossing, while the separate receiver supplies the switching state. External transfer control samples that state before coordinating release, after the actual carrier geometry and seated tolerance have been checked.

Problem Solved

A carrier-arrival reference helps external transfer control coordinate a staged handoff, using an interrupted optical path to distinguish the seated carrier from an empty stop.

Carrier arrival Transfer stop Separate receiver

3. Monitoring an opaque strip edge at a guide

A strip guide can position the sender and receiver across a defined edge location so that an opaque strip normally interrupts the beam. Lateral movement that uncovers the path changes the receiver output. External process control evaluates that condition as a discrete edge-presence reference, with strip opacity, flutter and actual alignment checked during installation.

Problem Solved

A discrete strip-edge reference helps external process control recognize an uncovered guide position without requiring a reflective target surface or a reflector behind the moving strip.

Opaque strip Edge presence Through-beam optics
Select your currency