Festo 571061 Direct 3/2 Solenoid Valve, 24 V DC, ISO 15218

Original price was: USD 69.68.Current price is: USD 60.58.

15 mm normally closed sub-base valve with mechanical spring reset, 18 l/min nominal flow, 6 ms on/off switching, 1.8 W coil and Type C electrical interface.

SKU Festo-571061 Category
Festo Solenoid Valves

Festo VSCS-B-M32-MD-WA-1C1 Solenoid Valve

BrandFesto
Model IdentifierVSCS-B-M32-MD-WA-1C1
Official Part Number571061

Technical Overview

The Festo VSCS-B-M32-MD-WA-1C1 is a direct-acting, normally closed 3/2-way solenoid valve with mechanical spring reset and a 15 mm construction width. Its pneumatic interface uses a size 15 mm sub-base to ISO 15218, with 18 l/min standard nominal flow and a 0–10 bar operating range. A Type C electrical connection to DIN EN 175301-803 supplies 24 V DC actuation with 1.8 W characteristic coil power. Switch-on and switch-off times are both 6 ms. The soft-sealing valve includes detenting and non-detenting manual override, IP65 protection and −10 to 50 °C ambient/media limits; the manufacturer specifies switching at least once per week.

15 mm direct-acting normally closed 3/2 valve with ISO 15218 sub-base, 18 l/min nominal flow, 24 V DC coil and Type C connection.

Key Features

  • Normally closed single-solenoid 3/2-way function
  • Direct actuation with mechanical spring reset
  • 15 mm construction width; size 15 mm sub-base to ISO 15218
  • 18 l/min standard nominal flow to DIN 1343
  • Sub-base connections at supply, working and exhaust ports
  • 0–10 bar operating range; non-reversible flow
  • 24 V DC, 1.8 W coil with −15%/+10% voltage tolerance
  • Type C electrical connection to DIN EN 175301-803
  • 6 ms switch-on and 6 ms switch-off times; 100% duty cycle
  • Detenting/non-detenting manual override, IP65 and −10 to 50 °C ambient/media range

Switch an ISO 15218 size 15 mm sub-base circuit directly from 24 V DC with 6 ms component switching times.

Technical Specification Matrix

ParameterValue
Valve function3/2-way, single solenoid, closed
Type of actuationElectrical
Construction width15 mm
Standard nominal flow rate (standardised to DIN 1343)18 l/min
pneumatic working portSub-base size 15 mm to ISO 15218
Operating voltage24 V DC
Operating pressure0 MPa...1 MPa; 0 bar...10 bar; 0 psi...145 psi
Type of resetMechanical spring
Approvalc UL us - Recognised (Oil)
Degree of protectionIP65
Sealing principleSoft
Mounting positionAny
Conforms to standardISO 15218
Manual overrideDetenting; Non-detenting
Type of pilotingDirect
Flow directionNon-reversible
lapUnderlap
Note on forced dynamizationSwitching frequency min. 1/week
Switching time off6 ms
Switching time on6 ms
Duty cycle100%
Max. positive test pulse with 0 signal1800 µs
Max. negative test pulse with 1 signal800 µs
Characteristic coil data24 V DC: 1.8 W
Permissible voltage fluctuations-15% / +10%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-C1-L
Media temperature-10 °C...50 °C
Ambient temperature-10 °C...50 °C
Electrical connectionType C; To DIN EN 175301-803
Pneumatic connection, port 1Sub-base
Pneumatic connection, port 2Sub-base
Pneumatic connection, port 3Sub-base
Note on materialsRoHS compliant
Material sealsNBR

Industrial Applications

1. Commanded Air Nozzle Supply

A packaging station supplies an air nozzle only during a release or clearing step. The normally closed 3/2-way function provides the commanded pressurization path and an unactuated working-line exhaust state. Its ISO 15218 sub-base working port connects the branch, while 18 l/min nominal flow and 6 ms on/6 ms off component times characterize the selected valve.

Problem Solved

The valve applies air on an electrical command and supplies a defined exhaust routing state afterward, giving the nozzle branch two pneumatic states within the machine sequence.

3/2 normally closed ISO 15218 sub-base working port 18 l/min

2. Electrical Command for a Pneumatic Pilot Element

An automated fixture uses a downstream pneumatic control element and needs an electrical command stage. The 24 V DC solenoid switches the valve’s working path, with mechanical spring reset providing the alternate valve state. A Type C interface defines the electrical interface, and the valve’s 0–10 bar working range defines the compressed-air condition for the command stage.

Problem Solved

Electrical actuation converts the controller command into pressure-and-exhaust routing for the downstream pilot element, with mechanical spring reset providing the specified alternate switching state.

24 V DC Mechanical spring reset 0–10 bar

3. Single-Acting Fixture Actuator Control

A small fixture uses a suitable single-acting pneumatic actuator that needs pressure applied during a process step and its line exhausted afterward. This 3/2-way valve supplies those two routing states through an ISO 15218 sub-base working connection. Its 15 mm construction width and sub-base supply/exhaust interfaces organize the valve at the fixture’s pneumatic control station.

Problem Solved

One working port alternates the actuator line between supply and exhaust, while sub-base supply connections provide an organized mounting interface for the fixture’s pneumatic command stage.

Single working port 15 mm width Sub-base supply/exhaust