Technical Overview

The SICK VTE18-4P8240 is an energetic photoelectric proximity sensor with infrared LED illumination and a PNP switching output. It evaluates target-reflected light from one mounting side, avoiding a separate receiver or reflector across the monitored area. The specified sensing range is 10–700 mm, with a maximum of 10–800 mm on a white reference target having 90% remission. Its LED forms a 40 mm at 800 mm spot, and a 270° potentiometer adjusts detection. An L/D control connection selects light or dark switching. Response of no more than 2 ms, 250 Hz switching, M12 4-pin connector and an IP67 nickel-plated brass housing support machine integration.

PNP infrared energetic sensor with 10–700 mm sensing, 270° adjustment, selectable light/dark switching and M12 4-pin connector.

Key Features

  • Energetic photoelectric proximity sensing
  • 10–700 mm sensing range
  • 10–800 mm maximum range on 90% remission white reference
  • Infrared LED; Ø40 mm at 800 mm
  • 270° sensing-range potentiometer
  • PNP output; light/dark selected via L/D control connection
  • Control connection open: dark switching
  • Response ≤2 ms; 250 Hz switching
  • Axial M18 × 1 nickel-plated brass housing; IP67
  • M12 4-pin connector; 10–30 V DC operation

Detect reflected target light from one mounting side with a metal M18 sensor and select light/dark PNP output logic through the control connection.

Technical Specification Matrix

ParameterValue
Functional principleEnergetic photoelectric proximity sensor
Sensing range10–700 mm
Maximum sensing range10–800 mm on 90% remission white target (DIN 5033)
Light sourceLED, infrared light
Light spot sizeØ40 mm at 800 mm
Angle of dispersionApproximately 2.8°
AdjustmentPotentiometer, 270°, for sensing range
Optical axisAxial
Housing formCylindrical, M18 × 1
Power supply10–30 V DC; limit values
Residual ripple±10%; remain within supply-voltage limits
Current consumption30 mA without load
Switching outputPNP
Switching modeLight/dark switching, selectable via L/D control connection; control connection open = dark switching D.ON
Output current≤100 mA
Response time≤2 ms with resistive load
Switching frequency250 Hz at light/dark ratio 1:1
ConnectionMale connector M12, 4-pin
Circuit protectionSupply/input/output reverse-polarity protection, interference suppression and output overcurrent/short-circuit protection
Protection classIII
Housing materialMetal, nickel-plated brass
Optics materialPMMA plastic
IP ratingIP67
Operating temperature−25 to +70 °C
UL fileNMFT2.E175606
Dimensions L x W x H (cm)7.8 x 1.8 x 1.8
Physical Weight (kg)0.12

Industrial Applications

1. Checking a workpiece in a fixture

An assembly fixture can position the sensor toward the expected face of an opaque workpiece, with clear optical separation from surfaces behind the detection point. Energetic sensing evaluates reflected target light, and the potentiometer sets reception for the installed geometry. The PNP output supplies the local presence state to the sequence controller.

Problem Solved

A contactless workpiece signal identifies an occupied fixture for the controller, supporting assembly sequencing without a mechanical feeler pressing against the part at the sensing position.

Energetic sensing PNP Potentiometer

2. Counting separated components on a conveyor

A conveyor can aim the sensor at a position crossed by separated opaque parts so each target presents reflected light to the receiver. The 40 mm at 800 mm optical spot defines the monitored region, while the potentiometer adapts reception to the target and background geometry. The 250 Hz switching frequency supports repeated transitions within the documented timing limits.

Problem Solved

Discrete reflected-light transitions mark individual part passages without contact, giving the controller a count input when the installed geometry separates each target from the empty path.

Ø40 mm at 800 mm 250 Hz Diffuse sensing

3. Checking opaque strip continuity

A feeder can direct the sensor toward an opaque strip at a fixed monitoring position so reflected light indicates material present. A break or runout removes the target from that optical position and changes the PNP signal. IP67 protection supports exposed machine mounting, while the 2 m cable connects to local control wiring.

Problem Solved

A change in local material presence provides an electrical indication of interrupted strip feed, helping the controller coordinate a response before additional product enters the affected process section.

Material continuity IP67 PNP
Select your currency