Sale!

Festo 573420 Solenoid Valve, 5/3 Exhausted, 10 mm, 24 V DC

Original price was: USD 81.38.Current price is: USD 70.72.

Flange-interface valve with 200 l/min nominal flow, external 3–8 bar pilot supply, spring reset, E-box connection and IP65/IP67 protection.

SKU Festo-573420 Category
Festo Solenoid Valves

Festo VUVG-B10-P53E-ZT-F-1T1L Solenoid Valve

BrandFesto
Model IdentifierVUVG-B10-P53E-ZT-F-1T1L
Official Part Number573420

Technical Overview

The Festo VUVG-B10-P53E-ZT-F-1T1L is a 10 mm 5/3-way solenoid valve with an exhausted centre and mechanical spring reset. Its flange pneumatic interface and manifold-rail mounting support a grouped valve assembly, with 200 l/min standard nominal flow. External pilot air at 3–8 bar operates separately from the −0.9 to 10 bar working circuit, and flow direction is reversible. The operating interface is rated 24 V DC through an E-box; characteristic coil data separately specify 22 V DC and 1.0 W. The 58 g valve offers LED indication, manual override, IP65/IP67 protection and documented 12 ms on, 38 ms off and 16 ms reversal times.

10 mm 5/3-way exhausted-centre flange valve with external pilot supply, spring reset, E-box connection and 200 l/min nominal flow.

Key Features

  • 5/3-way directional function with exhausted centre
  • 10 mm valve size and flange pneumatic working interface
  • 200 l/min standard nominal flow to DIN 1343
  • External pilot supply at 3–8 bar
  • −0.9 to 10 bar working range with reversible flow
  • Mechanical spring reset and manifold-rail mounting
  • 24 V DC operating interface; coil data 22 V DC, 1.0 W
  • 12 ms on, 38 ms off and 16 ms reversal times; 3 Hz maximum switching
  • 100% duty cycle with LED indication and manual override
  • 58 g product weight with IP65/IP67 protection

Provide two directional commands and an exhausted-centre state in a 10 mm flange valve with separate pilot air and 200 l/min nominal flow.

Technical Specification Matrix

ParameterValue
Valve function5/3 exhausted
Type of actuationElectrical
Valve size10 mm
Standard nominal flow rate (standardised to DIN 1343)200 l/min
pneumatic working portFlange
Operating voltage24 V DC
Operating pressure-0.09 MPa...1 MPa; -0.9 bar...10 bar
DesignPiston gate valve
Type of resetMechanical spring
Approvalc UL us - Recognised (Oil)
Degree of protectionIP65; IP67
Exhaust-air functionCan be throttled
Sealing principleSoft
Mounting positionAny
Manual overrideDetenting; Non-detenting
Type of pilotingPiloted
Pilot air supplyExternal
Flow directionReversible
lapIndeterminate overlap
Signal status displayLED
Pilot pressure0.3 MPa...0.8 MPa; 3 bar...8 bar
Max. switching frequency3 Hz
Switching time off38 ms
Switching time on12 ms
Switching time reversal16 ms
Duty cycle100%
Max. positive test pulse with 0 signal1600 µs
Max. negative test pulse with 1 signal3000 µs
Characteristic coil data22 V DC: 1.0 W
Permissible voltage fluctuations+/-10%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Media temperature-5 °C...60 °C
Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Ambient temperature-5 °C...60 °C
Physical Weight (kg)0.058
Electrical connectionVia E-box
Type of mountingOn manifold rail
Note on materialsRoHS compliant
Material sealsHNBR; NBR
Material housingWrought aluminium alloy

Industrial Applications

1. Transfer Cylinder with a Vented Neutral Circuit State

A machine moves a suitable double-acting cylinder in two directions and requires a valve neutral state that connects the working circuit to exhaust. The 5/3 exhausted-centre function supplies those three routing states, while mechanical spring reset returns the valve to its centre. The 200 l/min nominal flow and flange interface characterize the selected valve within its manifold arrangement.

Problem Solved

The exhausted centre supplies a distinct vented routing state between directional commands, supporting a cylinder circuit that requires working-line exhaust rather than closed valve paths in neutral.

5/3 exhausted centre 200 l/min Spring reset

2. Gripper Control with Separate Pilot Pressure

A handling machine uses a suitable double-acting gripper circuit whose working pressure differs from the valve actuation supply. External pilot air at 3–8 bar operates this valve independently of its −0.9 to 10 bar working range. The two directional states command the gripper circuit, and the exhausted centre provides a third routing state when working-line exhaust is required by the mechanism's pneumatic sequence.

Problem Solved

Separate pilot air supports valve actuation at a defined positive pressure while the gripper working circuit uses its own pressure condition and the specified three-state routing function.

External pilot 3–8 bar pilot Exhausted neutral

3. Reversible Pneumatic Motor Routing

A machine uses a suitable reversible pneumatic motor and needs forward, reverse and vented neutral air-routing commands. This valve supplies a 5/3 exhausted-centre function through its flange interface, with an E-box electrical connection for the commands. The specified 16 ms reversal time and 3 Hz maximum switching frequency characterize the valve component; the motor's mechanical run-down remains a property of the complete drive and load.

Problem Solved

One electrically commanded valve provides forward, reverse and vented neutral routing states, with documented timing limits for evaluating its place in the pneumatic motor command sequence.

Forward/reverse/vented neutral 16 ms reversal 3 Hz maximum
Select your currency