1. Three-State Linear Transfer Control
A pneumatic transfer axis needs extension, retraction and a neutral command between machine steps. The 5/3-way valve routes air for the two directions and provides a closed-centre third state. Flange working ports and 520–600 l/min standard nominal flow define the valve interface, while external pilot air supplies the control pressure independently of the working circuit.
Problem Solved
A closed-centre third state blocks the valve's working paths between directional commands, giving the controller a distinct neutral circuit state alongside extension and retraction.
5/3-way closed centre
Flange working ports
520–600 l/min nominal
2. Gripper Circuit with a Neutral Valve State
A handling machine operates a suitable double-acting gripper through open, close and neutral commands. The closed-centre valve function provides the third air-routing state, while mechanical spring reset returns the spool when actuation is removed. A three-pin M8 electrical connection and manifold-rail mounting define the local control interface; the 3–8 bar external pilot supply operates separately from the working-air pressure.
Problem Solved
Three valve states provide directional and neutral commands for the gripper circuit, while external pilot operation separates the spool-control supply from the working-air pressure.
Closed centre
Spring reset
Manifold mounting
3. Reversible Pneumatic Motor Command Circuit
A machine uses a suitable reversible pneumatic motor for a positioning or winding task. The 5/3-way arrangement provides two directional air-routing commands and a closed-centre neutral command through flange working ports. The documented 20 ms reversal time characterizes the valve transition for sequence planning; motor run-down and mechanical stopping behavior depend on the complete motor and load system.
Problem Solved
One directional valve supplies forward, reverse and neutral routing commands, allowing the controller to select each circuit state through the three-pin M8 electrical connection.
Forward/reverse/neutral
24 V DC
20 ms reversal