1. Fixture Clamp and Ejector Sequencing
A compact assembly fixture uses separate single-acting clamp and ejector circuits at different points in its cycle. The dual normally closed 3/2-way functions provide two supply-and-exhaust switching paths in one 14 mm valve body. Pneumatic spring reset returns each function with pilot air available, while the flange interface and E-box connection define the fixture's pneumatic and electrical connections.
Problem Solved
Two monostable switching functions consolidate the clamp and ejector air commands in one compact valve, supporting separate process steps without using two individual valve bodies.
2 × 3/2-way NC
14 mm body
Flange interface
2. Two-Zone Air-Blast Commands
A small packaging station directs compressed-air blasts to two separate process points, such as a part-release point and a tooling surface. Two normally closed 3/2-way functions let the machine sequence command the respective air circuits. The documented 10 ms switch-on and 29 ms switch-off times provide valve timing information for planning those commands alongside tubing and nozzle response.
Problem Solved
Separate normally closed air paths support two timed blast commands in one valve package, with published switching times providing a concrete basis for the pneumatic sequence.
2 pneumatic functions
10 ms on
29 ms off
3. Electrical-to-Pneumatic Pilot Signal Conversion
A machine uses pneumatic commands to actuate two downstream control functions. The dual 3/2-way valve converts 24 V DC electrical actuation into two normally closed pneumatic switching paths, with spring reset and a flange interface. Its external pilot supply and compact manifold mounting support grouping these signal-conversion functions with the machine's other pneumatic controls with 1.5–8 bar external pilot pressure and a 1.5–10 bar working range.
Problem Solved
A compact dual-function valve links electrical sequence outputs to pneumatic command circuits, while spring reset supplies a defined monostable return action for each switching path.
24 V DC
External pilot
Spring reset