Sale!

Festo 566459 Solenoid Valve, 5/3 Closed, M5, 24 V DC

Original price was: USD 63.96.Current price is: USD 55.64.

Internally piloted 10 mm valve with 210 l/min nominal flow, mechanical spring reset, electrical sub-base interface and 3–8 bar operation.

SKU Festo-566459 Category
Festo Solenoid Valves

Festo VUVG-L10-P53C-T-M5-1P3 5/3-Way Closed-Centre Valve

BrandFesto
Model IdentifierVUVG-L10-P53C-T-M5-1P3
Official Part Number566459

Technical Overview

The Festo VUVG-L10-P53C-T-M5-1P3 is a 10 mm 5/3-way solenoid valve with a closed centre and mechanical spring reset. Internal pilot air requires a 3–8 bar operating range; this variant is not suitable for vacuum. Its M5 ports provide 210 l/min standard nominal flow, with 11 ms switch-on, 30 ms switch-off and 14 ms reversal times. The 24 V DC valve connects through an electrical sub-base and supports manifold-rail or through-hole mounting. The 55 g assembly has a wrought aluminium housing and documented Class 5 cleanroom suitability. Protection is IP40, with IP65 specified when fitted with the plug socket.

10 mm internally piloted 5/3-way closed-centre valve with M5 ports, 24 V DC electrical sub-base interface and 210 l/min nominal flow.

Key Features

  • 5/3-way closed-centre directional function
  • 10 mm valve size and M5 pneumatic ports
  • 210 l/min standard nominal flow to DIN 1343
  • Internal pilot supply and 3–8 bar operation
  • Mechanical spring reset; not suitable for vacuum
  • 24 V DC coil with 1.0 W high-current and 0.3 W low-current phases
  • 11 ms on, 30 ms off and 14 ms reversal times
  • 100% duty cycle and electrical sub-base connection
  • IP40 protection; IP65 with plug socket
  • 55 g product weight and Class 5 cleanroom suitability

Provide forward, reverse and closed-centre states through M5 working ports, with internal pilot air and 210 l/min nominal flow.

Technical Specification Matrix

ParameterValue
Valve function5/3-way, closed
Type of actuationElectrical
Valve size10 mm
Standard nominal flow rate (standardised to DIN 1343)210 l/min
pneumatic working portM5
Operating voltage24 V DC
Operating pressure0.3 MPa...0.8 MPa; 3 bar...8 bar
DesignPiston gate valve
Type of resetMechanical spring
ApprovalRCM; c UL us - Recognised (Oil)
CE mark (see declaration of conformity)To EU EMC Directive; To EU Low Voltage Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions; To UK regulations for electrical equipment
Degree of protectionIP40; IP65; With plug socket
Nominal size3.2 mm
Exhaust-air functionCan be throttled
Sealing principleSoft
Mounting positionAny
Manual overrideDetenting; Non-detenting; Concealed
Type of pilotingPiloted
Pilot air supplyInternal
lapOverlap
Pilot pressure0.3 MPa...0.8 MPa; 3 bar...8 bar
Suitability for vacuumNo
Switching time off30 ms
Switching time on11 ms
Switching time reversal14 ms
Duty cycle100%
Max. positive test pulse with 0 signal700 µs
Max. negative test pulse with 1 signal900 µs
Characteristic coil data24 V DC: 1.0 W; 24 V DC: low-current phase 0.3 W, high-current phase 1.0 W
Permissible voltage fluctuations+/-10%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Restrictions for environmental and media temperature-5 - 50 °C; Without holding current reduction
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitability, measured according to ISO 14644-14Class 5 according to ISO 14644-1
Media temperature-5 °C...60 °C
Ambient temperature-5 °C...60 °C
Physical Weight (kg)0.055
Electrical connectionVia electrical sub-base
Type of mountingEither:; On manifold rail; With through-hole
Pneumatic connection, port 1M5
Pneumatic connection, port 2M5
Pneumatic connection, port 3M5
Pneumatic connection, port 4M5
Pneumatic connection, port 5M5
Note on materialsRoHS compliant
Material sealsHNBR; NBR
Material housingWrought aluminium alloy

Industrial Applications

1. Three-State Linear Transfer Control

A pneumatic transfer axis needs extension, retraction and a neutral command between machine steps. The 5/3-way valve connects a double-acting cylinder to two directional states and a closed-centre state. Its M5 ports and 210 l/min standard nominal flow provide a defined connection and flow basis for selecting the surrounding cylinder circuit.

Problem Solved

A closed-centre third state blocks the valve's working paths between directional commands, giving the controller a distinct neutral circuit state alongside extension and retraction.

5/3-way closed centre M5 210 l/min nominal

2. Gripper Circuit with a Neutral Valve State

A handling machine operates a suitable double-acting pneumatic gripper through open, close and neutral valve commands. The closed-centre function supplies the third circuit state, while mechanical spring reset returns the spool when its actuation is removed. Internal pilot operation at 3–8 bar, an electrical sub-base connection and manifold-rail mounting characterize the documented control arrangement for this exact valve.

Problem Solved

Three valve states support a gripper sequence with a defined neutral connection state, while internal piloting and manifold mounting consolidate the pneumatic control assembly.

Closed centre Spring reset Manifold mounting

3. Reversible Pneumatic Motor Command Circuit

A machine uses a suitable reversible pneumatic motor for a positioning or winding task. The 5/3-way arrangement provides two directional air-routing commands and a closed-centre neutral command through the M5 working ports. The specified switching times support sequence planning; the motor's run-down and mechanical stopping behaviour remain properties of the complete motor and load system.

Problem Solved

One directional valve provides forward, reverse and neutral air-routing commands, allowing the machine controller to select the required circuit state through the electrical sub-base interface.

Forward/reverse/neutral 24 V DC 14 ms reversal
Select your currency