Pilot-actuated valve with -0.9 to 10 bar operating pressure and external pilot supply. 20ms switching time, HNBR/NBR seals, and G1/8 connections.

SKU Festo-575675 Category
Universal directional control valves

VUVS-L20-M52-AZD-G18-F7 Festo Solenoid valve

Model Identifier VUVS-L20-M52-AZD-G18-F7
Official Part Number 575675
GTIN Standard 4052568104108

Technical Overview

The VUVS-L20-M52-AZD-G18-F7 is a high-performance 5/2-way monostable solenoid valve featuring a piston gate valve design and electric actuation. Built with a durable die-cast aluminum housing and pneumatic spring reset, it delivers a standard nominal flow rate of 700 l/min. This universal directional control valve is optimized for moderate corrosion stress environments and is suitable for both manifold rail and through-hole mounting configurations.

Key Features

  • 5/2-way, monostable function
  • Piston gate valve design
  • Electric actuation with external pilot air supply
  • Pneumatic spring reset
  • Soft sealing principle
  • Detenting and non-detenting manual override
  • Reversible flow direction
  • RoHS-compliant materials
  • Cleanroom suitability Class 6 according to ISO 14644-1

High standard nominal flow rate of 700 l/min in a compact 21 mm valve size.

Technical Specification Matrix

ParameterValue
Valve function5/2-way, monostable
Type of actuationElectric
Valve size21 mm
Standard nominal flow rate700 l/min
Pneumatic working portG1/8
Operating pressure (MPa)-0.09 MPa ... 1 MPa
Operating pressure (bar)-0.9 bar ... 10 bar
DesignPiston gate valve
Type of resetPneumatic spring
Approvalc UL us - Recognized (OL)
Nominal size5.7 mm
Exhaust-air functionWith flow control option
Sealing principleSoft
Mounting positionoptional
Manual overrideDetenting Non-detenting
Type of pilotingPilot actuated
Pilot air supplyExternal
Flow directionReversible
Symbol00991026
LapOverlap
Pilot pressure (MPa)0.25 MPa ... 1 MPa
Pilot pressure (bar)2.5 bar ... 10 bar
b value0.35
C value2.9 l/sbar
Switching time off29 ms
Switching time on20 ms
Max. positive test pulse with 0 signal1900 µs
Max. negative test pulse with 1 signal2700 µs
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitabilityClass 6 according to ISO 14644-1
Media temperature-10 °C ... 60 °C
Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Ambient temperature-10 °C ... 60 °C
Product weight188 g
Type of mountingOn manifold rail With through-hole
Breather connectionNot ducted
Pneumatic spring connection 12M5
Pilot exhaust port 84M5
Pilot air port 14M5
Pneumatic connection, port 1G1/8
Pneumatic connection, port 2G1/8
Pneumatic connection, port 3G1/8
Pneumatic connection, port 4G1/8
Pneumatic connection, port 5G1/8
Note on materialsRoHS-compliant
Material sealsHNBR NBR
Material housingDie-cast aluminium Painted
Material piston slideWrought aluminium alloy
Material screwsGalvanised steel

Industrial Applications

1. Low-Impact Pneumatic Clamping for Electronics Assembly

Used to control low-pressure pneumatic cylinders during the assembly of fragile smartphone components (e.g., screens or PCBs). The valve isolates the high-pressure pilot air from the low-pressure working air, allowing the cylinders to operate gently at 0.5 to 1.5 bar without stalling the valve.

Problem Solved

Prevents damage to delicate electronic parts caused by standard 6-bar clamping forces. Standard internal-pilot valves fail to switch at low pressures (<2.5 bar), but this external pilot model allows the main line to run at very low pressures while maintaining reliable high-speed switching.

External Pilot (AZD)Operating Pressure -0.9 bar ... 10 barCleanroom Class 6Pilot Pressure 2.5 bar ... 10 bar

2. Vacuum-Driven Wafer Handling in Photovoltaic Manufacturing

Controls double-acting vacuum actuators or routes vacuum to suction cups for lifting brittle solar wafers. The valve directs the vacuum source to the gripping head while venting the other port to the atmosphere, ensuring rapid grip and release cycles in a cleanroom environment.

Problem Solved

Enables reliable switching of negative pressure (vacuum) for handling extremely brittle materials where positive pressure cannot be used. The high nominal flow rate (700 l/min) ensures rapid evacuation and fast cycle times required for high-volume solar cell production.

Operating Pressure -0.9 bar (Vacuum)Standard Nominal Flow Rate 700 l/min5/2-way MonostableISO Class 6 Cleanroom

3. Reliable Actuation in Woodworking Machines with Fluctuating Air Supply

Operates pneumatic clamps and stops on large woodworking CNC routers where the main plant air supply fluctuates due to heavy intermittent loads. The external pilot supply ensures the valve switches firmly even if the main line pressure drops momentarily.

Problem Solved

Eliminates valve stalling and incomplete actuation caused by pressure dips in the main plant air supply (dirty/fluctuating air). The separation of the pilot and power units protects the control mechanism from pressure spikes and ensures safety-critical clamping remains engaged.

External Pilot Air SupplyVibration Resistance Level 2Pneumatic Spring ResetCRC 2 Corrosion Resistance

[Download-Datasheet]

Select your currency