SICK 1019249 WL34-R230 Relay Retro-reflective Sensor

USD 154.44

WL34-R230 offers polarized red-light retro-reflective sensing, isolated relay change-over contacts, 20–250 V AC/DC supply and M16-gland terminals.

SKU SICK-1019249 Category
SICK W34

SICK WL34-R230 Relay Retro-reflective Photoelectric Sensor

BrandSICK
Model IdentifierWL34-R230
Official Part Number1019249

Technical Overview

The SICK WL34-R230 is a polarized retro-reflective photoelectric sensor using a passive reflector to return its visible red beam. The dual-lens optical system requires a minimum reflector distance; with PL80A, the sensing range is 0.03–15 m and maximum range 0.03–22 m. A sensitivity potentiometer, light/dark selector, alignment sight and received-light indication support commissioning. Electrically isolated relay change-over contacts provide the control interface, with response no more than 10 ms and 10 Hz switching at a 1:1 light/dark ratio. The sensor accepts 20–250 V AC/DC, consumes less than 2 VA and uses M16-gland terminal wiring in an IP67 ABS housing.

Polarized red-light retro-reflective sensor with 0.03–15 m PL80A sensing range, isolated relay change-over contacts and 20–250 V AC/DC supply.

Key Features

  • Polarized retro-reflective sensing with minimum-distance dual-lens optics
  • PL80A reflector: 0.03–15 m sensing range; 0.03–22 m maximum
  • 660 nm visible red LED; Ø250 mm spot at 15 m
  • Sensitivity potentiometer, light/dark selector and alignment sight
  • Electrically isolated relay with change-over contacts
  • ≤10 ms response; 10 Hz switching at 1:1 light/dark ratio
  • 20–250 V AC/DC supply; <2 VA consumption
  • Terminal connection with M16 gland, rotatable by 90°
  • IP67 ABS housing; −40 to +60 °C operation
  • 140 g product weight

Detect interruption of a returned red beam and provide isolated relay change-over contacts, with sensitivity and light/dark selection for commissioning.

Technical Specification Matrix

ParameterValue
Functional principlePhotoelectric retro-reflective sensor; dual-lens system with minimum reflector distance
Maximum sensing range0.03–22 m with PL80A reflector
Light sourceVisible red LED; average LED service life 100,000 h at +25 °C
Wavelength660 nm
Light spot sizeØ250 mm at 15 m
Sensitivity adjustmentPotentiometer
Switching outputElectrically isolated relay with change-over contacts
Switching modeLight/dark switching, selectable via separate selector
Switching current4 A at 250 V AC; 4 A at 24 V DC; 0.125 A at 250 V DC
UL contact ratings4 A at 250 V AC general use; resistive 4 A NO / 3 A NC at 250 V AC; general use 4 A NO / 3 A NC at 24 V DC; R300 / B300 for NO contacts only
Load suppressionProvide suitable spark suppression for inductive or capacitive loads
Usage categoryAC-15, DC-13; EN 60947-1
Response time≤10 ms
Switching frequency10 Hz at 1:1 light/dark ratio
Power supply20–250 V AC/DC
Power consumption<2 VA
Circuit protectionSupply connections reverse-polarity protected; interference suppression
Protection classII; rated voltage 250 V AC/DC
ConnectionTerminal connection with M16 gland; screw fixing rotatable by 90°
Terminal assignmentCD-167: 1=L1; 2=N; relay change-over contacts at terminals 3–5, connect according to manufacturer contact diagram
MountingØ5.5 mm mounting hole for M5 hexagon nuts on both sides
Housing materialABS plastic
IP ratingIP67
Operating temperature−40 to +60 °C
Storage temperature−40 to +75 °C
MTTFD478 years; entire-device value must be calculated using B10D, actual switching cycles and the given MTTFD for electro-mechanical components
B10D59,123 switching cycles; observe manufacturer calculation condition
Diagnostic coverageDCavg 0%
Mission time20 years
Sensing range0.03–15 m with PL80A reflector
Polarization filterYes
AdjustmentSensitivity potentiometer; separate light/dark selector
IndicatorsReceived-light / signal-strength indicator; alignment sight
Reflector-specific rangesPL80A: 0.03–15 m sensing / 0.03–22 m maximum; PL50A and PL40A: 0.03–11 / 0.03–16 m; PL30A, PL20A and Diamond Grade tape: 0.03–7 / 0.03–10 m; C110A: 0.15–10 / 0.15–13 m
Physical Weight (kg)0.14

Industrial Applications

1. Counting opaque loads across a conveyor opening

A conveyor can place the sensor on one side and a passive reflector on the other, with each separated opaque load interrupting the returned beam. External counting logic evaluates the isolated relay change-over contacts. Commissioning checks actual reflector type, gap and load spacing against the documented range and switching limits, then sets sensitivity using representative operating conditions.

Problem Solved

A returned-beam interruption gives external counting logic a load-passage reference while the passive reflector avoids electrical wiring on the opposite side of the conveyor.

Load passage Passive reflector External counting

2. Monitoring occupancy at a transfer position

A transfer position can locate the returned beam through the space occupied by a waiting load. External sequencing logic evaluates the isolated relay change-over contacts and monitors a sustained blocked condition to regulate upstream release. Setup aligns the sensor and reflector, checks signal indication and confirms reliable interruption with the actual target and surrounding surfaces.

Problem Solved

A sustained beam-state reference helps external transfer logic identify an occupied position and coordinate upstream feeding before another load enters the monitored space.

Transfer occupancy Beam state Machine sequencing

3. Checking continuity of an opaque material feed

An opaque material feed can run between the sensor and a passive reflector so intact material blocks the returned optical path. A gap or runout changes the received-light condition for external monitoring logic. Commissioning checks the material’s actual opacity, available reflector distance and signal margin, then verifies that the connected control input interprets the switching state as intended.

Problem Solved

A changed optical-path state helps external feed monitoring recognize an opening in expected opaque material, using a non-contact reference at the installed sensing position.

Material continuity Opaque feed Returned beam
Select your currency