SICK 6037839 WFM180-120N311 NPN Optical Fork Sensor

USD 231.40

Red-light optical fork with 180 mm opening, 1 mm minimum object, NPN light switching, 4 kHz operation and an M8 three-pin connector.

SKU SICK-6037839 Category
SICK WFM

SICK WFM180-120N311 NPN Optical Fork Sensor

BrandSICK
Model IdentifierWFM180-120N311
Official Part Number6037839

Technical Overview

The SICK WFM180-120N311 is a visible-red-LED optical fork sensor with an NPN light-switching output. Its 180 mm fork opening accommodates guided targets crossing the optical axis, with a specified minimum detectable object of 1 mm. This version has no adjustment, providing a fixed detection setting for repeat machine tasks. The sensor combines 4 kHz switching, response no greater than 125 µs and response-time stability of ±15 µs. A 10–30 V DC supply, M8 three-pin connector, IP67 aluminum housing and −10 to +60 °C operating range support installation, with a 140 ms initialization period after power-up.

Red-LED optical fork sensor with 180 mm opening, 1 mm minimum object, fixed NPN light switching, 4 kHz operation and M8 three-pin connector.

Key Features

  • Visible red LED optical detection
  • 180 mm fork opening
  • Minimum detectable object 1 mm
  • Fixed setting with no adjustment possibility
  • NPN output; light switching
  • 4 kHz switching and response ≤125 µs
  • Response-time stability ±15 µs; 140 ms initialization
  • 10–30 V DC; <20 mA no-load consumption; maximum output current 100 mA
  • M8 three-pin connector; pin 1 L+, pin 3 M, pin 4 Q
  • IP67 aluminum housing; −10 to +60 °C operation

Detect targets crossing a 180 mm optical fork with a fixed light-switching NPN signal and no sensitivity-adjustment step.

Technical Specification Matrix

ParameterValue
Functional principleOptical fork detection
Light sourceLED, visible red light
Fork opening180 mm
Minimum detectable object1 mm
AdjustmentNone
IndicatorsYellow function indicator for switching output; visible red transmitted light
Power supply10–30 V DC
Residual ripple<10%
Current consumption<20 mA without load
Initialization time140 ms
Switching frequency4 kHz
Response time≤125 µs
Response-time stability±15 µs
Switching outputNPN
Output voltageNPN HIGH approximately supply voltage; LOW ≤1.5 V
Switching modeLight switching
Output current100 mA maximum
Protection classIII; reference voltage DC 50 V
Circuit protectionSupply reverse-polarity protection, output Q short-circuit protection and interference-pulse suppression
ConnectionM8 three-pin connector
Pin assignment1/BN: L+; 3/BU: M; 4/BK: Q
Housing materialAluminum
Housing thickness10 mm, excluding connector profile
Mounting holesØ4.3 mm
IP ratingIP67
Operating temperature−10 to +60 °C
Storage temperature−40 to +80 °C
Ambient light immunity≤10,000 lx
Shock resistanceAccording to EN 60068-2-27
MTTFD131 years
Diagnostic coverage DCavg0%
UL fileNRKH.E191603 and NRKH7.E191603

Industrial Applications

1. Counting parts leaving a guided feeder

A guided feeder can carry individual parts through the fork so each opaque target interrupts the red-light path. The fixed light-switching output supplies a pulse to an external counter. Targets must meet the 1 mm minimum detectable-object specification, and the 4 kHz switching frequency and response limit define the timing available between successive parts. This light-switching NPN output is active when the optical path is clear.

Problem Solved

A qualified beam-interruption event gives the external counter a part-passage reference, supporting quantity tracking at the feeder exit without a mechanical counting lever touching the components.

Part counting 1 mm MDO 4 kHz

2. Indexing a carrier with an opaque flag

A moving carrier can carry an opaque reference flag through the 180 mm fork opening at a designated station. The NPN output changes when the flag crosses the optical axis. The fixed setting and response no greater than 125 µs define switching behavior for an external controller using one configured edge as a discrete position reference. This light-switching NPN output is active when the optical path is clear.

Problem Solved

The flag provides a discrete carrier-position event for the machine controller, helping coordinate a station cycle without a contact cam or adjustable sensitivity setting at that reference point.

Carrier indexing 180 mm opening NPN

3. Checking a component at an assembly fixture

An assembly fixture can position the fork so a seated component interrupts the light path at the inspection point. A component that leaves the path clear produces the opposite switching condition. The external controller reads that condition before advancing the assembly sequence, using the 1 mm minimum detectable object and fixed light-switching configuration as selection limits. This light-switching NPN output is active when the optical path is clear.

Problem Solved

A local beam-state check distinguishes the qualified seated-component condition from an empty fixture at the monitored point, allowing the controller to flag a missing-part condition before the next operation.

Fixture presence Light switching No adjustment
Select your currency