| Functional principle | Fiber-optic amplifier; expansion unit |
| Sensing principle and range | Dependent on the optical fiber cable used |
| Light source | LED, visible red light |
| Wavelength | 650 nm |
| LED risk group | Free group, EN 62471:2008-09 / IEC 62471:2006 modified |
| Adjustment | Display and operating buttons for sensor parameters; configurable wire input for sender deactivation, test logic, range setting or synchronization |
| Display | 2 × 4-digit numeric display: green threshold/operating mode; red actual value, teach-in and function parameters |
| Digital output | 1 × NPN, selectable via menu |
| Switching mode | Light/dark switching, manually selectable |
| Response time | Selectable ≤16 / 70 / 250 / 2,000 / 8,000 µs |
| Switching frequency | Corresponding settings: 31.2 kHz / 7.1 kHz / 2 kHz / 250 Hz / 62.5 Hz |
| Time functions | No delay, off delay, switch-on delay, ON and OFF delay, one shot; timer function also supports switch-on delay and pulse |
| Delay time | Programmable 0–9,999 ms |
| Input/output configuration | Black wire: configurable digital Q1; white wire: configurable teach-in input |
| Power supply | 12–24 V DC, ±10% |
| Residual ripple | ≤10%; remain within supply-voltage limits |
| Current consumption | ≤50 mA without load |
| Protection class | III |
| Output protection | Reverse polarity, overcurrent and short-circuit protected |
| Connection | 2-wire, 2 m PVC cable; do not bend below 0 °C |
| Conductor cross-section | 0.2 mm² |
| Housing form | Rectangular |
| Housing material | ABS/PC plastic |
| IP rating | IP50, EN 60529 |
| Items supplied | BEF-WLL180 mounting bracket |
| Operating temperature | −25 to +55 °C, subject to connected-device derating |
| Storage temperature | −40 to +70 °C |
| Relative humidity | 35–85%, no condensation |
| Ambient light immunity | Artificial light ≤3,000 lx; sunlight ≤10,000 lx |
| Shock resistance | 50 g, 11 ms, 18 shocks across X/Y/Z axes; EN 60068-2-27 |
| Vibration resistance | 10–55 Hz, 1 mm amplitude, 3 × 30 min; EN 60068-2-6 |
| Electromagnetic compatibility | EN 60947-5-2 |
| UL file | NRKH.E300503 |
| MTTFD | 365 years |
| Diagnostic coverage DCavg | 0% |
| Mission time | 20 years |
| Dimensions L x W x H (cm) | 7.19 x 1.05 x 3.46 |
| Physical Weight (kg) | 0.025 |
| System configuration | Expansion unit for use in a compatible WLL180T base-unit arrangement |
| Connected-device derating | 4–8 devices: −25 to +50 °C with output current 50 mA; 9–16 devices: −25 to +45 °C with output current 20 mA |