SICK 6039104 WLL180T-E434 NPN Fiber-Optic Amplifier

USD 185.12

Expansion unit fiber amplifier with NPN output, programmable 0–9,999 ms delays, two-by-four-digit display, M8 four-pin connector and IP50 housing.

SKU SICK-6039104 Category
SICK WLL180T

SICK WLL180T-E434 NPN Fiber-Optic Amplifier

BrandSICK
Model IdentifierWLL180T-E434
Official Part Number6039104

Technical Overview

The SICK WLL180T-E434 is a expansion unit fiber-optic amplifier with one NPN output and a 650 nm visible red LED. The connected fiber determines the sensing arrangement and available range. It adds a sensing channel to a compatible base/expansion assembly through its bus connector; its external supply terminals are reserved for the base unit. Selectable response settings span 16–8,000 µs, with listed switching frequencies ranging from 31.2 kHz to 62.5 Hz. A two-by-four-digit display and operating buttons support threshold adjustment and parameter setup. Programmable 0–9,999 ms delays, M8 four-pin connector, 12–24 V DC operation and an IP50 ABS/PC housing support integration. Grouped-operation limits are −25 to +50 °C at 50 mA output for 4–8 devices, or −25 to +45 °C at 20 mA for 9–16 devices.

Expansion unit fiber-optic amplifier with one NPN output, programmable timing, a two-by-four-digit display and M8 four-pin connector.

Key Features

  • Expansion unit fiber amplifier; one NPN output
  • Sensing arrangement and range depend on the connected fiber
  • 650 nm visible red LED
  • Manually selectable light/dark switching
  • Two-by-four-digit display with parameter and teach buttons
  • Programmable on/off delays and one-shot functions, 0–9,999 ms
  • 12–24 V DC supply, ±10%; M8 four-pin connector
  • IP50 ABS/PC housing; BEF-WLL180 bracket supplied
  • Selectable response ≤16 / 70 / 250 / 2,000 / 8,000 µs
  • Grouped-operation temperature/output-current derating applies

Adjust a fiber-guided detection channel from the amplifier display, with programmable switching delays for external machine control.

Technical Specification Matrix

ParameterValue
Functional principleFiber-optic amplifier; expansion unit
Sensing principle and rangeDependent on the optical fiber cable used
Light sourceLED, visible red light
Wavelength650 nm
LED risk groupFree group, EN 62471:2008-09 / IEC 62471:2006 modified
AdjustmentDisplay and operating buttons for sensor parameters; configurable wire input for sender deactivation, test logic, range setting or synchronization
Display2 × 4-digit numeric display: green threshold/operating mode; red actual value, teach-in and function parameters
Digital output1 × NPN, selectable via menu
Switching modeLight/dark switching, manually selectable
Response timeSelectable ≤16 / 70 / 250 / 2,000 / 8,000 µs
Switching frequencyListed settings:31.2 kHz /7.1 kHz /2 kHz /250 Hz /62.5 Hz
Time functionsNo delay, off delay, switch-on delay, ON and OFF delay, one shot; timer function also supports switch-on delay and pulse
Delay timeProgrammable 0–9,999 ms
Input/output configuration4/BK=Q; 2=external input; CD-140 marks 1/BN=L+ and 3/BU=M for the base unit only; expansion uses its bus connection
Power supply12–24 V DC, ±10%
Residual ripple≤10%; remain within supply-voltage limits
Current consumption≤50 mA without load
Protection classIII
Output protectionReverse polarity, overcurrent and short-circuit protected
ConnectionM8 four-pin connector
Housing formRectangular
Housing materialABS/PC plastic
IP ratingIP50, EN 60529
Items suppliedBEF-WLL180 mounting bracket
Operating temperature−25 to +55 °C; 4–8 connected devices: −25 to +50 °C at 50 mA output; 9–16 devices: −25 to +45 °C at 20 mA output
Storage temperature−40 to +70 °C
Relative humidity35–85%, no condensation
Ambient light immunityArtificial light ≤3,000 lx; sunlight ≤10,000 lx
Shock resistance50 g, 11 ms, 18 shocks across X/Y/Z axes; EN 60068-2-27
Vibration resistance10–55 Hz, 1 mm amplitude, 3 × 30 min; EN 60068-2-6
Electromagnetic compatibilityEN 60947-5-2
UL fileNRKH.E300503 and NRKH7.E300503
MTTFD365 years
Diagnostic coverage DCavg0%
Mission time20 years
Physical Weight (kg)0.02
Expansion connectionBus connector for compatible base/expansion assembly; supply connections in the wiring diagram are base-unit-only

Industrial Applications

1. Counting separated components through a fiber beam

In a compatible base/expansion assembly, a feeder can use a compatible through-beam fiber arrangement across the component path, with the expansion amplifier evaluating the returned optical signal. Each separated opaque component interrupts the beam and changes the NPN output state. The selected response setting establishes transition timing, while the digital display shows the received value and switching threshold.

Problem Solved

Fiber-guided sensing brings the detection point into a constrained component path, producing count events while the amplifier remains accessible for threshold adjustment and signal review.

Fiber-dependent optics NPN Selectable response

2. Checking a part in a confined assembly fixture

In a compatible base/expansion assembly, an assembly fixture can position a compatible reflective fiber head near the expected part location while mounting the amplifier in an accessible machine area. The fiber determines the optical sensing arrangement, and the amplifier display and operating buttons establish the switching threshold. The NPN output reports the resulting part-presence state to the controller.

Problem Solved

Separating the optical head from the amplifier allows a local presence check in a confined fixture while keeping the adjustment controls and received-signal display accessible.

Remote fiber head Digital display Part presence

3. Bridging short gaps in sheet feed

In a compatible base/expansion assembly, a sheet feeder can use a compatible fiber arrangement to monitor material in a narrow feed path. The amplifier evaluates the light-state changes and applies a programmed off delay so brief gaps do not immediately release the output. A longer absence allows the configured timing to expire, providing a changed NPN signal to the controller.

Problem Solved

A timed material-presence signal bridges short feed gaps, helping the controller distinguish brief interruptions from sustained runout while the fiber head occupies the constrained sensing location.

Off delay 0–9,999 ms NPN
Select your currency