SICK 1123755 WTV4FE-8416A120A00 V-optics IO-Link Sensor

USD 221.00

V-optics background suppression with 2–50 mm reference-white sensing, 0.5 × 1.9 mm spot at 30 mm, push-pull output, BluePilot and IO-Link V1.1.

SKU SICK-1123755 Category
SICK W4

SICK WTV4FE-8416A120A00 V-optics Photoelectric Sensor

BrandSICK
Model IdentifierWTV4FE-8416A120A00
Official Part Number1123755

Technical Overview

The SICK WTV4FE-8416A120A00 is a background-suppression photoelectric proximity sensor with V-optics and a rectangular red PinPoint LED spot measuring 0.5 × 1.9 mm at 30 mm. Its 2–50 mm sensing range applies to 90% remission reference white, with an adjustable background-suppression threshold of 15–50 mm and recommended best-performance range of 15–30 mm. BluePilot Teach-Turn adjustment sets the sensing range, while IO-Link V1.1 configures sensor parameters and Smart Task functions. One push-pull PNP/NPN digital output is preset for light switching; pin 2 is initially inactive. The 10–30 V DC unit connects through an M12 four-pin cable plug and provides IP66/IP67 protection with VISTAL housing and PMMA optics.

V-optics background-suppression sensor with 2–50 mm reference-white range, BluePilot Teach-Turn adjustment, push-pull light switching and IO-Link V1.1.

Key Features

  • Background suppression with V-optics; manufacturer identifies transparent-object detection
  • 2–50 mm sensing on 90% remission reference white; adjustable threshold 15–50 mm
  • Recommended best-performance sensing range 15–30 mm
  • 635 nm red PinPoint LED; rectangular 0.5 × 1.9 mm spot at 30 mm
  • Typical smallest detectable object 0.1 mm at 30 mm on 90% remission reference white
  • BluePilot Teach-Turn range adjustment; IO-Link V1.1 COM2
  • One push-pull PNP/NPN output, preset light switching; pin 2 initially inactive
  • Standard response ≤500 µs; 1,000 Hz at 1:1 light/dark ratio; Smart Task timing differs
  • 10–30 V DC; M12 four-pin cable plug; PVC cable
  • IP66/IP67 VISTAL housing and PMMA front screen; −40 to +60 °C operation

Set a close-range target zone with V-optics and BluePilot, then read the switching condition and live receiver level through the configured IO-Link connection.

Technical Specification Matrix

ParameterValue
Functional principlePhotoelectric proximity sensor; background suppression with V-optics
Sensing range2–50 mm on 90% remission reference white, DIN 5033
Adjustable background-suppression threshold15–50 mm
Recommended sensing range15–30 mm for best performance
Minimum background separation1 mm at 21 mm distance; black 6% target / white 90% background
Light sourceVisible red PinPoint LED; 635 nm
Light spot sizeRectangular 0.5 × 1.9 mm at 30 mm
Squint angle<±1.5° at TU = +23 °C
LED risk groupFree group; EN 62471:2008-09 and IEC 62471:2006, modified
Average LED service life100,000 h at Ta = +25 °C
Smallest detectable objectTypical 0.1 mm at 30 mm on 90% remission reference white, DIN 5033
AdjustmentBluePilot Teach-Turn for sensing range; IO-Link for sensor parameters and Smart Task
IndicationBlue=range indicator; green steady=power, flashing=IO-Link; yellow steady=object present, off=object absent
Manufacturer special applicationDetecting transparent objects
Communication interfaceIO-Link V1.1; COM2, 38.4 kBaud
IO-Link cycle time2.3 ms
Process data length16 bit
Process data structureBit 0=QL1; bit 1=QL2; bits 2–15=current receiver level, live
IO-Link identifiersVendorID 26; DeviceID 0x8002EA / 8389354
Compatible master portType A
SIO modeSupported
Power supply10–30 V DC, limit values
Ripple≤5 Vpp
Usage categoryDC-12 and DC-13; EN 60947-5-2
Current consumption≤25 mA without load at 24 V DC
Protection classIII
Digital outputOne push-pull PNP/NPN output; current ≤100 mA
Switching modeLight switching preset; object present → QL1 HIGH
Signal voltage PNP HIGH/LOWApproximately UB−2.5 V / 0 V
Signal voltage NPN HIGH/LOWApproximately UB / <2.5 V
Output protectionReverse polarity, overcurrent and short circuit
Standard response time≤500 µs; use Smart Task timing when enabled
Standard response repeatability150 µs; signal transit time with resistive load in switching mode
Standard switching frequency1,000 Hz at 1:1 light/dark ratio; Smart Task limits differ
Pin assignment1 BN=L+; 2 WH=MF, initially inactive; 3 BU=M; 4 BK=QL1/C; pin functions configurable via IO-Link; do not connect switching output to another output
ConnectionCable with four-pin M12 male plug; manufacturer connection length 182 mm
Cable length L140 mm; connector length 42 mm in drawing
Cable materialPVC; do not bend below 0 °C
Conductor cross-section0.14 mm²
Cable diameter3.4 mm
Housing designRectangular, flat
Housing materialVISTAL plastic
Front screen materialPMMA plastic
Male connector materialVISTAL plastic
Maximum fixing-screw torque0.4 Nm
Mounting holesM3
IP ratingIP66 / IP67, EN 60529
Operating temperature−40 to +60 °C
Storage temperature−40 to +75 °C
Typical ambient light immunityArtificial light and sunlight ≤50,000 lx
Shock resistance30 g, 11 ms; three positive and three negative shocks on each X/Y/Z axis, 18 total; EN 60068-2-27
Vibration resistance10–1,000 Hz; 1 mm amplitude; 3 × 30 min; EN 60068-2-6
Relative humidity35–95%, non-condensing
EMCEN 60947-5-2
Cleaning-agent resistanceECOLAB
UL filesNRKH.E181493 and NRKH7.E181493
Smart TaskBase logics: Direct, AND, OR; inverter available
Smart Task timersDeactivated; switch-on delay; off delay; ON and OFF delay; impulse/one shot
Smart Task frequencySIO Logic 900 Hz without IO-Link communication; IOL 800 Hz with IO-Link communication
Smart Task response timeSIO Logic 550 µs; IOL 600 µs
Smart Task response repeatabilitySIO Logic 200 µs; IOL 250 µs
Diagnostic dataQualitative device temperature: very cold/cold/moderate/warm/hot; device and detailed status; operating-hour counters including resettable counter; quality of teach
High-gloss installation exampleAt set range x=30 mm: β −7° to +7°; α −12° to +5°; follow manufacturer angle diagrams
Glass-pane installation exampleTransparent pane before 18% remission background, set range x=30 mm and object-to-background d≥200 mm: β −6° to +6°; α −4° to +7°
MTTFD1,439 years
DCavg0%
Mission time20 years
Physical Weight (kg)0.03

Industrial Applications

1. Checking a small insert in an assembly nest

An assembly nest can hold a small insert within the recommended 15–30 mm working range and present it to the rectangular light spot. BluePilot establishes the background-suppression threshold, and external inspection logic samples the light-switching output after the assembly settles. Commissioning checks actual insert reflectance and orientation; the documented typical 0.1 mm object value applies at 30 mm on reference white.

Problem Solved

A close-range insert-present reference helps external inspection logic identify an omitted component in a presented nest, using a small rectangular spot and an adjusted background-suppression threshold.

Small insert V-optics Background suppression

2. Checking a presented glass pane before handling

A glass-handling fixture can present a transparent pane at a controlled gap and orientation before the next movement. The manufacturer identifies transparent-object detection and gives an example at a 30 mm set range with at least 200 mm to an 18% remission background. Setup follows the corresponding β and α acceptance diagrams, then external handling logic reads the commissioned switching condition.

Problem Solved

A transparent-pane presence reference helps external handling logic distinguish a presented pane from an empty fixture position, using the documented V-optics arrangement and installation-specific acceptance angles.

Transparent pane Controlled background V-optics

3. Reviewing receiver-level changes at an inspection station

An inspection station can retain the sensor’s switching result while maintenance logic reads its 16-bit IO-Link process data. Bits 2–15 report the current receiver level, and diagnostic data provide quality-of-teach and operating-history context. The machine can compare those observations with its commissioned target condition to prompt inspection of alignment or contamination, without treating receiver level as a distance measurement.

Problem Solved

Live receiver-level and diagnostic observations give external maintenance logic context for investigating a changing optical condition, helping personnel focus inspection on the target presentation and sensor installation.

IO-Link diagnostics Receiver level Maintenance review