SICK 1085344 RLY3-OSSD200 ReLy OSSD Safety Relay

USD 185.12

RLY3-OSSD200 evaluates safety sensors with OSSDs, providing two safe enabling paths, manual/automatic reset, EDM and separate diagnostic outputs.

SKU SICK-1085344 Category
SICK Safety Relays

SICK RLY3-OSSD200 ReLy OSSD Safety Relay

BrandSICK
Model IdentifierRLY3-OSSD200
Official Part Number1085344

Technical Overview

The SICK RLY3-OSSD200 ReLy is an evaluation unit for safety sensors with OSSDs. Two safety inputs and a reset or external-device-monitoring input control two positively guided normally-open enabling paths. Sequence monitoring, restart interlock, automatic or manual reset and EDM support a hard-wired protective-function design. Two non-safe diagnostic outputs and one non-safe test-pulse output provide separate auxiliary signals. Component ratings include SIL 3, category 4, PL e and stop category 0, with a 20-year mission time. The device uses a 24 V DC PELV or SELV supply over a 16.8–30 V range and front spring terminals. Its IP20 housing operates from −25 to +55 °C.

OSSD safety-sensor evaluation relay with two safe enabling paths, manual/automatic reset, restart interlock, EDM and separate non-safe diagnostic outputs.

Key Features

  • Evaluation unit for safety sensors with OSSDs
  • Two safety inputs; one reset/EDM input
  • Two positively guided normally-open safe enabling paths; 10 ms opening response
  • Sequence monitoring, restart interlock, manual or automatic reset and EDM
  • SIL 3; category 4; PL e; stop category 0; 20-year mission time
  • Two non-safe push-pull diagnostic outputs; one non-safe PNP test-pulse output
  • 24 V DC PELV/SELV supply; 16.8–30 V operating range; ≤2.5 W
  • Enabling paths: 10–230 V AC or DC; 10 mA–6 A; total current 12 A
  • Front spring terminals; hard-wired configuration; LED indication
  • IP20; −25 to +55 °C operation; 130 g product weight

Evaluate a compatible OSSD safety sensor through two positively guided enabling paths, with reset, EDM and diagnostic signals configured through hard wiring.

Technical Specification Matrix

ParameterValue
ApplicationEvaluation unit for safety sensors with OSSDs
Safety integrity levelSIL 3, IEC 61508
CategoryCategory 4, ISO 13849-1
Performance levelPL e, ISO 13849-1
PFHD1.0 × 10⁻⁹ per hour
Mission time20 years, ISO 13849-1
Stop category0, IEC 60204-1
Monitoring functionsSequence monitoring; restart interlock; external device monitoring (EDM)
ResetManual or automatic
Safety inputsTwo
Reset/EDM inputOne
Safety input levelsHIGH 11–30 V DC, nominal 24 V; LOW −3 to +5 V DC, nominal 0 V; current 4–6 mA
Accepted safety-input test pulsesWidth ≤1 ms; rate ≤10 Hz
Reset/EDM input levelsHIGH 11–30 V DC, nominal 24 V; LOW −3 to +5 V DC, nominal 0 V; current 4–6 mA
Enabling current pathsTwo safe normally-open positively guided contacts
Opening response time10 ms
Contact materialSilver alloy, gold flashed
Switching voltage10–230 V AC; 10–230 V DC
Switching current10 mA–6 A
Total current12 A
Mechanical life10,000,000 switching cycles
Overvoltage categoryIII, EN 60664-1
Rated impulse withstand voltage6 kV, EN 60664-1
Diagnostic outputsTwo non-safe short-circuit-protected push-pull semiconductor outputs
Diagnostic output levelsHIGH ≥supply voltage −3 V; LOW ≤3 V
Diagnostic current limitsNPN sink/input current ≤15 mA; PNP source/output current ≤120 mA
Test-pulse outputOne non-safe PNP semiconductor output, short-circuit protected
Test-pulse output voltage≥supply voltage −3 V
Test-pulse timing2 ms width; 40 ms interval
Power supply24 V DC, 16.8–30 V; PELV or SELV
Residual ripple≤2.4 V
Power consumption≤2.5 W DC
ConnectionFront connector with spring terminals
ConfigurationHard wired
IndicationLEDs
IP ratingIP20, IEC 60529
Operating temperature−25 to +55 °C
Storage temperature−25 to +70 °C
Relative humidity≤95%, non-condensing
Interference emissionIEC 61000-6-4
Interference resistanceIEC 61326-3-1; IEC 61000-6-2; IEC 60947-5-1
Physical Weight (kg)0.13
Dimensions L x W x H (cm)8.77 x 2.01 x 12.83

Industrial Applications

1. Evaluating a light curtain through relay enabling paths

A compatible safety light curtain can connect its two OSSD signals to the relay’s safety inputs. The hard-wired relay evaluates the sensor condition and supplies two positively guided normally-open enabling paths to the external shutdown circuit. The protective-function design accounts for the relay’s 10 ms opening response together with sensor, contactor and machine stopping behavior.

Problem Solved

Two evaluated OSSD inputs provide a relay-based interface to the external shutdown circuit, supporting a validated protective function with defined enabling contacts and documented opening response.

Light-curtain evaluation OSSD inputs Enabling contacts

2. Supervising a restart request and external contactors

An access-protection circuit can use manual reset and external device monitoring to coordinate a restart request after the connected OSSD sensor permits operation. The relay’s reset/EDM input and documented contactor feedback arrangement let the protective-function design evaluate the external switching devices. Hard wiring establishes the selected reset behavior, with commissioning checking the complete restart and feedback sequence.

Problem Solved

Reset and contactor-feedback supervision help the protective-function design coordinate deliberate restart with the external switching devices, using the relay’s documented monitoring and restart-interlock functions.

Manual reset Contactor feedback Restart supervision

3. Displaying protective-circuit status in ordinary machine diagnostics

Ordinary machine diagnostic logic can read the relay’s two separate push-pull diagnostic outputs to display protective-circuit status. The interface observes the stated HIGH/LOW voltages and source/sink current limits. These non-safe signals support the operator display, while the two dedicated enabling paths perform their separate role in the validated protective circuit and local LEDs assist troubleshooting.

Problem Solved

Separate diagnostic signals give ordinary machine logic a status reference for operator displays and troubleshooting, keeping display wiring distinct from the relay’s dedicated safe enabling paths.

Operator diagnostics Push-pull outputs Status display