1. Evaluating a light curtain through relay enabling paths
A compatible safety light curtain can connect its two OSSD signals to the relay’s safety inputs. The hard-wired relay evaluates the sensor condition and supplies two positively guided normally-open enabling paths to the external shutdown circuit. The protective-function design accounts for the relay’s 10 ms opening response together with sensor, contactor and machine stopping behavior.
Problem Solved
Two evaluated OSSD inputs provide a relay-based interface to the external shutdown circuit, supporting a validated protective function with defined enabling contacts and documented opening response.
Light-curtain evaluation
OSSD inputs
Enabling contacts
2. Supervising a restart request and external contactors
An access-protection circuit can use manual reset and external device monitoring to coordinate a restart request after the connected OSSD sensor permits operation. The relay’s reset/EDM input and documented contactor feedback arrangement let the protective-function design evaluate the external switching devices. Hard wiring establishes the selected reset behavior, with commissioning checking the complete restart and feedback sequence.
Problem Solved
Reset and contactor-feedback supervision help the protective-function design coordinate deliberate restart with the external switching devices, using the relay’s documented monitoring and restart-interlock functions.
Manual reset
Contactor feedback
Restart supervision
3. Displaying protective-circuit status in ordinary machine diagnostics
Ordinary machine diagnostic logic can read the relay’s two separate push-pull diagnostic outputs to display protective-circuit status. The interface observes the stated HIGH/LOW voltages and source/sink current limits. These non-safe signals support the operator display, while the two dedicated enabling paths perform their separate role in the validated protective circuit and local LEDs assist troubleshooting.
Problem Solved
Separate diagnostic signals give ordinary machine logic a status reference for operator displays and troubleshooting, keeping display wiring distinct from the relay’s dedicated safe enabling paths.
Operator diagnostics
Push-pull outputs
Status display