SICK 6020149 IH04-0B8NS-VW1 4 mm NPN Inductive Sensor

USD 86.58

IH04-0B8NS-VW1 combines 0.8 mm nominal metal sensing, NPN NO output, 5,000 Hz switching, a 2 m cable and a smooth 4 mm stainless-steel housing.

SKU: SICK-6020149 Category:

Description

SICK IMM

SICK IH04-0B8NS-VW1 4 mm NPN Inductive Sensor

BrandSICK
Model IdentifierIH04-0B8NS-VW1
Official Part Number6020149

Technical Overview

The SICK IH04-0B8NS-VW1 is a miniature cylindrical inductive proximity sensor with a 4 mm smooth housing and an NPN normally open output. Its electromagnetic principle detects metal targets without an optical path, with a nominal sensing range of 0.8 mm and an assured range of 0.648 mm. Actual target material and geometry require qualification using the documented reference reduction factors. Flush installation and a 25 mm stainless-steel body suit compact fixtures. The sensor provides 5,000 Hz switching and operates from 10–30 V DC, with a 2 m three-wire PVC cable, POM sensing face and IP67 protection.

Smooth 4 mm inductive sensor with 0.8 mm nominal range, NPN NO output, 5,000 Hz switching, 2 m cable and stainless-steel body.

Key Features

  • Inductive metal detection in a smooth 4 mm cylindrical housing
  • 0.8 mm nominal range; 0.648 mm assured range
  • Flush installation; 25 mm housing length
  • NPN normally open output; DC three-wire wiring
  • 5,000 Hz switching frequency; ≤10 ms availability delay
  • 10–30 V DC operation; ≤20% residual ripple
  • Continuous output current ≤200 mA
  • V2A stainless-steel housing; POM sensing face
  • 2 m PVC cable; 0.14 mm² conductors; Ø3.5 mm cable
  • IP67; −25 to +70 °C operating range

Integrate contactless metal detection in a compact 4 mm cylindrical mounting point with a 0.8 mm nominal range and NPN normally open output.

Technical Specification Matrix

ParameterValue
Functional principleInductive proximity sensing of metal targets
Housing formSmooth cylindrical, standard design
Housing diameter4 mm
Nominal sensing range Sn0.8 mm
Assured sensing range Sa0.648 mm
Installation typeFlush
Switching frequency5,000 Hz
Switching outputNPN
Output functionNormally open (NO)
Electrical wiringDC 3-wire
ConnectionCable, 3-wire, 2 m
Power supply10–30 V DC
Residual ripple≤20% of supply voltage
Voltage drop≤2 V; manufacturer test condition Ia = 200 mA
Time delay before availability≤10 ms
Hysteresis1–10%
Reproducibility≤1.5% at constant supply and ambient temperature
Temperature drift±10% of Sr
Housing materialV2A stainless steel, DIN 1.4305 / AISI 303
Sensing face materialPOM plastic
Housing length25 mm
Cable jacket materialPVC
Conductor cross-section0.14 mm²
Cable diameterØ3.5 mm
IP ratingIP67 according to EN 60529
Operating temperature−25 to +70 °C
EMCEN 60947-5-2; IEC 61000-4-2 and IEC 61000-4-4 test level 2
Shock and vibration resistance30 g, 11 ms / 10–55 Hz, 1 mm
Reference material reduction factorsStainless steel V2A/304: approximately 0.8; aluminum: approximately 0.5; copper: approximately 0.45; brass: approximately 0.55; reference values may vary
MTTFD186 years
Diagnostic coverage DCavg0%
Mission time TM20 years
UL fileNRKH.E191603
Continuous output current≤200 mA

Industrial Applications

1. Confirming a metal part in a fixture

A machining fixture can place the sensor beside the expected location of a metal part so the target enters its assured sensing zone when seated. Flush installation allows mounting in the fixture face, and the NPN normally open output provides the presence signal. Target material must be considered using the documented reduction factors.

Problem Solved

A contactless metal-presence signal helps the sequence controller identify an occupied fixture position before the next operation, avoiding a mechanical feeler pressing against the seated part.

Flush mounting NPN NO Metal presence

2. Counting metal tabs on a rotating mechanism

A rotating mechanism can present separated metal tabs to the 4 mm sensing face and count each normally open output transition. The 5,000 Hz switching frequency supports repeated passages within the documented limits. Tab geometry, spacing, operating gap and material reduction factors must be qualified so consecutive targets produce distinct switching events.

Problem Solved

Discrete tab passages provide the controller with a pulse count related to mechanism rotation, supporting cycle counting without an optical beam or contacting follower on the moving tabs.

5,000 Hz Inductive NPN NO

3. Confirming a shuttle at a transfer position

A shuttle can carry a metal flag that enters the sensor’s local detection zone at a transfer position. The smooth 4 mm cylindrical housing supports installation in a suitable machine clamp, while the normally open NPN signal reports the flag state. IP67 protection and the stainless-steel body support exposed machine placement.

Problem Solved

A local position-confirmation signal helps the controller coordinate transfer sequencing when the metal flag reaches the monitored point, without a mechanical switch actuator following each shuttle movement.

4 mm smooth housing IP67 Metal flag