SICK IH04-0B8NS-VW1 4 mm NPN Inductive Sensor
Technical Overview
The SICK IH04-0B8NS-VW1 is a miniature cylindrical inductive proximity sensor with a 4 mm smooth housing and an NPN normally open output. Its electromagnetic principle detects metal targets without an optical path, with a nominal sensing range of 0.8 mm and an assured range of 0.648 mm. Actual target material and geometry require qualification using the documented reference reduction factors. Flush installation and a 25 mm stainless-steel body suit compact fixtures. The sensor provides 5,000 Hz switching and operates from 10–30 V DC, with a 2 m three-wire PVC cable, POM sensing face and IP67 protection.
Smooth 4 mm inductive sensor with 0.8 mm nominal range, NPN NO output, 5,000 Hz switching, 2 m cable and stainless-steel body.
Key Features
- Inductive metal detection in a smooth 4 mm cylindrical housing
- 0.8 mm nominal range; 0.648 mm assured range
- Flush installation; 25 mm housing length
- NPN normally open output; DC three-wire wiring
- 5,000 Hz switching frequency; ≤10 ms availability delay
- 10–30 V DC operation; ≤20% residual ripple
- Continuous output current ≤200 mA
- V2A stainless-steel housing; POM sensing face
- 2 m PVC cable; 0.14 mm² conductors; Ø3.5 mm cable
- IP67; −25 to +70 °C operating range
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Inductive proximity sensing of metal targets |
| Housing form | Smooth cylindrical, standard design |
| Housing diameter | 4 mm |
| Nominal sensing range Sn | 0.8 mm |
| Assured sensing range Sa | 0.648 mm |
| Installation type | Flush |
| Switching frequency | 5,000 Hz |
| Switching output | NPN |
| Output function | Normally open (NO) |
| Electrical wiring | DC 3-wire |
| Connection | Cable, 3-wire, 2 m |
| Power supply | 10–30 V DC |
| Residual ripple | ≤20% of supply voltage |
| Voltage drop | ≤2 V; manufacturer test condition Ia = 200 mA |
| Time delay before availability | ≤10 ms |
| Hysteresis | 1–10% |
| Reproducibility | ≤1.5% at constant supply and ambient temperature |
| Temperature drift | ±10% of Sr |
| Housing material | V2A stainless steel, DIN 1.4305 / AISI 303 |
| Sensing face material | POM plastic |
| Housing length | 25 mm |
| Cable jacket material | PVC |
| Conductor cross-section | 0.14 mm² |
| Cable diameter | Ø3.5 mm |
| IP rating | IP67 according to EN 60529 |
| Operating temperature | −25 to +70 °C |
| EMC | EN 60947-5-2; IEC 61000-4-2 and IEC 61000-4-4 test level 2 |
| Shock and vibration resistance | 30 g, 11 ms / 10–55 Hz, 1 mm |
| Reference material reduction factors | Stainless steel V2A/304: approximately 0.8; aluminum: approximately 0.5; copper: approximately 0.45; brass: approximately 0.55; reference values may vary |
| MTTFD | 186 years |
| Diagnostic coverage DCavg | 0% |
| Mission time TM | 20 years |
| UL file | NRKH.E191603 |
| Continuous output current | ≤200 mA |
Industrial Applications
1. Confirming a metal part in a fixture
A machining fixture can place the sensor beside the expected location of a metal part so the target enters its assured sensing zone when seated. Flush installation allows mounting in the fixture face, and the NPN normally open output provides the presence signal. Target material must be considered using the documented reduction factors.
A contactless metal-presence signal helps the sequence controller identify an occupied fixture position before the next operation, avoiding a mechanical feeler pressing against the seated part.
2. Counting metal tabs on a rotating mechanism
A rotating mechanism can present separated metal tabs to the 4 mm sensing face and count each normally open output transition. The 5,000 Hz switching frequency supports repeated passages within the documented limits. Tab geometry, spacing, operating gap and material reduction factors must be qualified so consecutive targets produce distinct switching events.
Discrete tab passages provide the controller with a pulse count related to mechanism rotation, supporting cycle counting without an optical beam or contacting follower on the moving tabs.
3. Confirming a shuttle at a transfer position
A shuttle can carry a metal flag that enters the sensor’s local detection zone at a transfer position. The smooth 4 mm cylindrical housing supports installation in a suitable machine clamp, while the normally open NPN signal reports the flag state. IP67 protection and the stainless-steel body support exposed machine placement.
A local position-confirmation signal helps the controller coordinate transfer sequencing when the metal flag reaches the monitored point, without a mechanical switch actuator following each shuttle movement.