Description
SICK LUT8U-11101 UV Luminescence Sensor
Technical Overview
The SICK LUT8U-11101 is a luminescence sensor that detects fluorescent targets using a 375 nm ultraviolet LED and a 450–750 nm receiving range. Its 0–20 mm working range and ≤10 mm sensing distance from the lens front support placement of qualified marks. A vertical 2 ×6 mm spot and a receiving filter that blocks wavelengths up to 420 nm separate target fluorescence from shorter-wavelength background emission. Manual rotary sensitivity adjustment sets the switching threshold. Separate PNP and NPN light-switching outputs and a 0–13 mA analog output support external control and signal monitoring. Switching frequency is 2.5 kHz, with a 200 µs response. The zinc diecast housing is rated IP67.
375 nm UV luminescence sensor with0–20 mm working range,2 ×6 mm vertical spot,PNP/NPN switching,0–13 mA analog output and M12 five-pin plug.
Key Features
- 375 nm ultraviolet LED;long-side light emission
- 450–750 nm receiving range;filter blocks wavelengths≤420 nm
- 0–20 mm working range;≤10 mm sensing distance from lens front
- 2 ×6 mm vertical light spot
- Separate PNP and NPN light-switching outputs;0–13 mA analog output
- 2.5 kHz switching at1:1 light/dark ratio;200 µs response
- Manual rotary sensitivity control
- Green luminescence-intensity bar graph;yellow switching indicator
- M12 five-pin plug;analog output on pin5
- Zinc diecast IP67 housing;−10 to+55 °C operation
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | UV luminescence detection of fluorescent targets |
| Housing form | Large |
| Light source | Ultraviolet LED |
| Wavelength | 375 nm |
| Light emission | Long housing side |
| Light spot size | 2 ×6 mm |
| Light spot direction | Vertical |
| Working range | 0–20 mm |
| Sensing distance | ≤10 mm from leading edge of lens |
| Receiving range | 450–750 nm |
| Receiving filter | Blocks wavelengths≤420 nm to suppress shorter-wavelength background luminescence |
| Power supply | 12–30 V DC;short-circuit-protected supply network maximum8 A |
| Ripple | <5 Vpp;supply voltage must remain within tolerances |
| Current consumption | <100 mA without load |
| Switching output | PNP and NPN,separate outputs |
| Switching mode | Light switching |
| Switching frequency | 2.5 kHz with light/dark ratio1:1 |
| Response time | 200 µs |
| Output current | Imax100 mA |
| Protection class | II;reference voltage50 V DC |
| Circuit protection | Supply reverse-polarity protection;Q short-circuit protection;interference pulse suppression |
| Connection | M12 five-pin plug |
| Connector adjustment | Rotatable up to90° |
| Housing material | Zinc diecast |
| Main body width | 30.4 mm |
| Main body height | 53 mm |
| Main body depth | 80 mm |
| Mounting | M5 threaded mounting holes,5.5 mm deep |
| Indicators | Yellow switching-output indicator;green bar graph with leftmost power-on LED |
| Operating temperature | −10 to+55 °C |
| Storage temperature | −25 to+75 °C |
| Shock load | IEC60068 |
| IP rating | IP67 |
| Physical Weight (kg) | 0.4 |
| Adjustment | Manual rotary sensitivity control |
| Analog output | 0–13 mA |
| Pin assignment | 1/BN=L+;3/BU=M;2/WH=Q NPN;4/BK=Q PNP;5/GY=QA analog;CD-312 |
| NPN switching output voltage | HIGH approximately supply voltage;LOW≤2 V |
| Bar graph | Luminescence intensity independently of switching-threshold setting |
Industrial Applications
1. Registering fluorescent marks on a moving web
A converting machine can move a qualified fluorescent registration mark and its background through the 2 ×6 mm vertical spot. The 375 nm UV source excites the mark and the receiver evaluates its visible emission. Manual sensitivity adjustment sets the mark/background threshold, and a compatible controller uses a switching transition as a timing reference within the 2.5 kHz switching condition.
A fluorescence-derived timing event gives the external web controller a registration reference when the mark is distinguished by UV-excited emission, without a mechanical index contact touching the moving material.
2. Checking qualified fluorescent adhesive at an assembly point
An assembly station can present an adhesive containing a qualified fluorescent tracer at a defined inspection location within the 0–20 mm working range. The sensor evaluates fluorescence against the local background using its threshold adjustment. The switching signal lets external control equipment inspect local adhesive presence; the test addresses the monitored spot and does not measure bond strength or full coverage.
A local fluorescence-presence condition lets the external inspection sequence flag a missing monitored adhesive spot without depending on a visible color difference or contacting the applied material.
3. Monitoring fluorescent-signal strength during setup
A machine setup station can connect the 0–13 mA analog signal to compatible external analog equipment while a qualified fluorescent target and its background are presented. The green local bar graph also displays luminescence intensity independently of the switching threshold. The operator can compare the external signal and the switching condition while setting manual sensitivity.
An intensity-related analog signal helps external setup equipment reveal changing fluorescence or background conditions without relying solely on whether the binary switching output has crossed its threshold.