Description
SICK WTB26P-24161120A00 IO-Link Background Suppression Sensor
Technical Overview
The SICK WTB26P-24161120A00 is a photoelectric proximity sensor with background suppression and a 30–1,600 mm sensing range on 90% remission reference white. BluePilot Teach-Turn adjustment sets the sensing distance, with an adjustable background-suppression threshold of 180–1,600 mm and a recommended 200–600 mm working region for best performance. A 635 nm visible red PinPoint LED produces a 7 mm spot at 700 mm. Two complementary push-pull PNP/NPN outputs provide light/dark switching, and IO-Link V1.1 configures parameters and Smart Task functions. The four-pin M12 connection, VISTAL housing, PMMA front screen and IP66/IP67/IP69 protection support machine installation from −40 to +60 °C.
IO-Link background-suppression sensor with 30–1,600 mm reference-white sensing, BluePilot Teach-Turn adjustment, complementary push-pull outputs and M12 connection.
Key Features
- Background suppression; 30–1,600 mm sensing on 90% remission reference white
- Adjustable background-suppression threshold 180–1,600 mm; recommended working region 200–600 mm
- 635 nm visible red PinPoint LED; Ø7 mm spot at 700 mm
- BluePilot Teach-Turn range setting and blue sensing-range indicator
- Two complementary push-pull PNP/NPN outputs; light/dark switching; maximum 100 mA
- IO-Link V1.1 COM2, 38.4 kBaud; 2.3 ms cycle; SIO support
- ≤500 µs response and 1,000 Hz in basic switching mode; Smart Task timing differs
- Smart Task base logic, timer functions and inverter; configuration through IO-Link
- M12 four-pin male connector; 10–30 V DC; ≤30 mA without load at 24 V
- VISTAL housing and connector; PMMA front screen; IP66/IP67/IP69; −40 to +60 °C operation
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Photoelectric proximity sensor with background suppression |
| Sensing range | 30–1,600 mm on 90% remission reference white, DIN 5033 |
| Adjustable switching threshold | 180–1,600 mm for background suppression |
| Recommended working range | 200–600 mm for best performance |
| Background separation example | 40 mm minimum between black 6% target at set distance 600 mm and white 90% background |
| Light source | Visible red PinPoint LED; point-shaped spot |
| Wavelength | 635 nm |
| Light spot size | Ø7 mm at 700 mm |
| Squint angle | <±1.0° at +23 °C |
| LED risk group | Free group; EN 62471:2008-09 / IEC 62471:2006, modified |
| LED service life | Average 100,000 h at +25 °C |
| Adjustment | BluePilot Teach-Turn for sensing range; IO-Link for parameters and Smart Task functions |
| Indicators | Blue: sensing range; green steady: power, flashing: IO-Link; yellow on: object present, off: object absent |
| Digital outputs | Two complementary push-pull PNP/NPN outputs; maximum current ≤100 mA |
| Switching mode | Light/dark switching |
| PNP signal voltage HIGH/LOW | Approximately Ub−2.5 V / 0 V |
| NPN signal voltage HIGH/LOW | Approximately Ub / <2.5 V |
| Response time | ≤500 µs with resistive load in basic switching mode |
| Response-time repeatability | 150 µs in basic switching mode |
| Switching frequency | 1,000 Hz at 1:1 light/dark ratio in basic switching mode |
| IO-Link | V1.1; COM2, 38.4 kBaud; 2.3 ms cycle |
| IO-Link process data | 16 bit: bit 0=QL1, bit 1=QL2, bits 2–15 empty |
| IO-Link identification | VendorID 26; DeviceID 0x800178 / 8388984 |
| Master port and SIO | Type A master port; SIO mode supported |
| Smart Task logic | Base logics: direct, AND, OR, window and hysteresis; inverter available |
| Smart Task timers | Deactivated; switch-on delay; off delay; ON and OFF delay; impulse (one shot) |
| Smart Task timing | SIO logic: 800 Hz, 600 µs response, 300 µs repeatability; IO-Link logic: 650 Hz, 750 µs response, 400 µs repeatability |
| Diagnosis | Device status and quality of teach |
| Connection | M12 four-pin male connector |
| Pin assignment | 1 BN=L+; 2 WH=MF, factory complementary dark output; 3 BU=M; 4 BK=QL1/C, factory light output and IO-Link (CD-390) |
| Output configuration | Pin 2 and pin 4 functions configurable through IO-Link; switching outputs must not be connected to another output |
| Power supply | 10–30 V DC, limit values |
| Ripple | ≤5 Vpp |
| Current consumption | ≤30 mA without load at 24 V DC |
| Output protection | Reverse-polarity, overcurrent and short-circuit protected |
| Protection class | III |
| Usage category | DC-12 / DC-13, EN 60947-5-2 |
| Housing and connector material | VISTAL plastic |
| Front screen material | PMMA plastic |
| IP rating | IP66, IP67 and IP69, EN 60529; IP69 replaces IP69K under ISO 20653:2013-03 |
| Operating temperature | −40 to +60 °C |
| Storage temperature | −40 to +75 °C |
| Relative humidity | 35–95%, noncondensing |
| Mounting holes | Ø5.2 mm |
| Maximum fixing-screw torque | 1.3 Nm |
| Shock resistance | 50 g, 11 ms, 150 shocks total; 50 g, 6 ms, 30,000 shocks total; EN 60068-2-27 |
| Vibration resistance | 10–2,000 Hz, 0.5 mm / 10 g, 20 sweeps per axis, 1 octave/min; EN 60068-2-6 |
| EMC | EN 60947-5-2 |
| Cleaning-agent resistance | ECOLAB |
| MTTFD | 626 years |
| DCavg | 0% |
| Mission time | 20 years |
| Physical Weight (kg) | 0.08 |
Industrial Applications
1. Counting separated cartons against a farther background
A conveyor can present separated cartons within the adjusted sensing region while a farther surface remains behind them. BluePilot sets the target distance, and background suppression establishes the detection boundary for the actual carton surfaces. External counting logic receives the switching condition, with commissioning checking target remission, background separation, spacing and timing in the selected operating mode.
A target-passage reference helps external counting logic register separated cartons from one mounting side, with the adjusted boundary checked against the real carton and background combination.
2. Checking a load on a presented carrier
A handling station can present a carrier so the expected load lies inside the adjusted target region and the empty carrier lies farther away. BluePilot sets the boundary using representative loaded and empty carriers. External inspection logic samples the complementary outputs after presentation, while setup checks surface remission, placement tolerance and the required separation from the background.
A load-present reference helps external inspection logic distinguish a loaded carrier from an empty presentation, supporting an omitted-load check before the next handling step.
3. Applying a configured delay to a process condition
A process station can use background-suppression detection as its input condition and configure an available Smart Task timer through IO-Link. A switch-on delay or off delay changes how that condition reaches external sequencing logic. Commissioning selects the intended function and verifies resulting behavior using the specified Smart Task response and switching limits, which differ from basic switching mode.
A configured timer helps external sequencing logic use a deliberately delayed detection condition, supporting application-specific timing without assuming the basic switching-mode response applies to Smart Task processing.