Description
Festo VMPA14-M1HF-NS-PI Dual Normally Open Solenoid Valve
Technical Overview
The Festo VMPA14-M1HF-NS-PI combines two normally open, monostable 3/2-way functions in a 14 mm solenoid valve with mechanical spring reset. It operates at 24 V DC over a −0.9 to 8 bar working range, with reversible flow and documented vacuum suitability. Nominal flow depends on the valve-terminal arrangement: the manufacturer's notes specify 470 l/min for MPA-S, 520 l/min for MPA-L and 550 l/min for MPA-C. The pilot-pressure range is 4–8 bar, with 12 ms switch-on and 20 ms switch-off times. Through-hole mounting, manual override and IP65 protection support installation; the exact valve weighs 77 g.
14 mm dual normally open 3/2-way solenoid valve with 24 V DC actuation, mechanical spring reset, reversible flow and vacuum suitability.
Key Features
- Two normally open, monostable 3/2-way functions
- 14 mm valve size with mechanical spring reset
- 24 V DC operation; permissible voltage variation ±25%
- −0.9 to 8 bar working pressure; 4–8 bar pilot pressure
- Reversible flow direction and documented vacuum suitability
- Nominal flow notes: MPA-S 470, MPA-L 520, MPA-C 550 l/min
- 12 ms switch-on and 20 ms switch-off times
- Detenting/non-detenting manual override and signal-status indication
- IP65 protection; 77 g product weight
- Through-hole mounting; 0.65 Nm maximum valve-mounting torque
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 2x3/2 open monostable |
| Type of actuation | Electrical |
| Valve size | 14 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 470 l/min...520 l/min |
| Operating voltage | 24 V DC |
| Operating pressure | -0.09 MPa...0.8 MPa; -0.9 bar...8 bar |
| Design | Piston gate valve |
| Type of reset | Mechanical spring |
| Approval | c UL us - Recognised (Oil) |
| Degree of protection | IP65; To IEC 60529 |
| Sealing principle | Soft |
| Mounting position | Any |
| Manual override | Detenting; Non-detenting |
| Type of piloting | Piloted |
| Flow direction | Reversible |
| lap | Overlap |
| Signal status display | Yes |
| Pilot pressure | 0.4 MPa...0.8 MPa; 4 bar...8 bar |
| Suitability for vacuum | Yes |
| Note on standard nominal flow rate | MPA-C: 550 l/min; MPA-L: 520 l/min; MPA-S: 470 l/min |
| Standard nominal flow rate with QS-8 | 470 l/min...550 l/min |
| Switching time off | 20 ms |
| Switching time on | 12 ms |
| Max. positive test pulse with 0 signal | 400 µs |
| Max. negative test pulse with 1 signal | 200 µs |
| Permissible voltage fluctuations | +/-25% |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 1 - Low corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Storage temperature | -20 °C...40 °C |
| Suitable for use with food | See supplementary material information |
| Media temperature | -5 °C...50 °C |
| Relative air humidity | Max. 90% at 40 °C |
| Ambient temperature | -5 °C...60 °C |
| Max. tightening torque for valve mounting | 0.65 Nm |
| Physical Weight (kg) | 0.077 |
| Type of mounting | With through-hole |
| Note on materials | RoHS compliant |
| Material seals | NBR |
| Material housing | Die-cast aluminium |
Industrial Applications
1. Normally Open Air-Purge Circuit Control
A machine circuit needs two air-purge lines whose specified normal valve state is open, with electrical commands changing the respective switching states. The dual normally open 3/2-way functions provide that arrangement in one 14 mm body. Mechanical spring reset returns the valve functions to their normal states, while the surrounding pneumatic circuit determines how each purge line is supplied and exhausted.
Two normally open functions support purge circuits designed around an open normal state, consolidating their electrical switching and spring return in a single compact valve body.
2. Normally Open Vacuum-Line Switching
A vacuum-handling circuit needs an electrically switched path with a normally open valve state. This model is explicitly suitable for vacuum, with a working-pressure limit of −0.9 bar and reversible flow direction. Its separate 4–8 bar pilot-pressure requirement defines the positive-pressure actuation conditions while the working circuit handles vacuum, supporting the chosen vacuum and venting arrangement.
Documented vacuum suitability and a normally open switching function provide a defined vacuum-circuit valve state, while the pilot-pressure specification separates actuation requirements from sub-atmospheric working pressure.
3. MPA Valve-Station Flow Planning
A machine builder selects a dual normally open function for an MPA valve station and needs a flow figure matched to the actual platform. The manufacturer lists different nominal flows for MPA-S, MPA-L and MPA-C installations. Keeping those conditions with the rating supports station planning alongside the valve's 14 mm size, through-hole mounting and documented mounting-torque limit.
Platform-specific flow information gives the builder a relevant rating for the chosen valve station, avoiding an unconditional flow assumption when integrating the dual normally open function.