Sale!

Festo 578819 Dual 3/2-Way NO Valve, 14 mm, 24 V DC

Original price was: USD 114.92.Current price is: USD 99.32.

Two normally open monostable functions with spring reset, reversible flow, vacuum suitability, IP65 protection and MPA-dependent nominal flow ratings.

SKU: Festo-578819 Category:

Description

Festo Solenoid Valves

Festo VMPA14-M1HF-NS-PI Dual Normally Open Solenoid Valve

BrandFesto
Model IdentifierVMPA14-M1HF-NS-PI
Official Part Number578819

Technical Overview

The Festo VMPA14-M1HF-NS-PI combines two normally open, monostable 3/2-way functions in a 14 mm solenoid valve with mechanical spring reset. It operates at 24 V DC over a −0.9 to 8 bar working range, with reversible flow and documented vacuum suitability. Nominal flow depends on the valve-terminal arrangement: the manufacturer's notes specify 470 l/min for MPA-S, 520 l/min for MPA-L and 550 l/min for MPA-C. The pilot-pressure range is 4–8 bar, with 12 ms switch-on and 20 ms switch-off times. Through-hole mounting, manual override and IP65 protection support installation; the exact valve weighs 77 g.

14 mm dual normally open 3/2-way solenoid valve with 24 V DC actuation, mechanical spring reset, reversible flow and vacuum suitability.

Key Features

  • Two normally open, monostable 3/2-way functions
  • 14 mm valve size with mechanical spring reset
  • 24 V DC operation; permissible voltage variation ±25%
  • −0.9 to 8 bar working pressure; 4–8 bar pilot pressure
  • Reversible flow direction and documented vacuum suitability
  • Nominal flow notes: MPA-S 470, MPA-L 520, MPA-C 550 l/min
  • 12 ms switch-on and 20 ms switch-off times
  • Detenting/non-detenting manual override and signal-status indication
  • IP65 protection; 77 g product weight
  • Through-hole mounting; 0.65 Nm maximum valve-mounting torque

Provide two normally open 3/2-way pneumatic functions with reversible flow and vacuum suitability in a 14 mm MPA valve.

Technical Specification Matrix

ParameterValue
Valve function2x3/2 open monostable
Type of actuationElectrical
Valve size14 mm
Standard nominal flow rate (standardised to DIN 1343)470 l/min...520 l/min
Operating voltage24 V DC
Operating pressure-0.09 MPa...0.8 MPa; -0.9 bar...8 bar
DesignPiston gate valve
Type of resetMechanical spring
Approvalc UL us - Recognised (Oil)
Degree of protectionIP65; To IEC 60529
Sealing principleSoft
Mounting positionAny
Manual overrideDetenting; Non-detenting
Type of pilotingPiloted
Flow directionReversible
lapOverlap
Signal status displayYes
Pilot pressure0.4 MPa...0.8 MPa; 4 bar...8 bar
Suitability for vacuumYes
Note on standard nominal flow rateMPA-C: 550 l/min; MPA-L: 520 l/min; MPA-S: 470 l/min
Standard nominal flow rate with QS-8470 l/min...550 l/min
Switching time off20 ms
Switching time on12 ms
Max. positive test pulse with 0 signal400 µs
Max. negative test pulse with 1 signal200 µs
Permissible voltage fluctuations+/-25%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC1 - Low corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Storage temperature-20 °C...40 °C
Suitable for use with foodSee supplementary material information
Media temperature-5 °C...50 °C
Relative air humidityMax. 90% at 40 °C
Ambient temperature-5 °C...60 °C
Max. tightening torque for valve mounting0.65 Nm
Physical Weight (kg)0.077
Type of mountingWith through-hole
Note on materialsRoHS compliant
Material sealsNBR
Material housingDie-cast aluminium

Industrial Applications

1. Normally Open Air-Purge Circuit Control

A machine circuit needs two air-purge lines whose specified normal valve state is open, with electrical commands changing the respective switching states. The dual normally open 3/2-way functions provide that arrangement in one 14 mm body. Mechanical spring reset returns the valve functions to their normal states, while the surrounding pneumatic circuit determines how each purge line is supplied and exhausted.

Problem Solved

Two normally open functions support purge circuits designed around an open normal state, consolidating their electrical switching and spring return in a single compact valve body.

2 × 3/2-way NO Mechanical spring reset 14 mm

2. Normally Open Vacuum-Line Switching

A vacuum-handling circuit needs an electrically switched path with a normally open valve state. This model is explicitly suitable for vacuum, with a working-pressure limit of −0.9 bar and reversible flow direction. Its separate 4–8 bar pilot-pressure requirement defines the positive-pressure actuation conditions while the working circuit handles vacuum, supporting the chosen vacuum and venting arrangement.

Problem Solved

Documented vacuum suitability and a normally open switching function provide a defined vacuum-circuit valve state, while the pilot-pressure specification separates actuation requirements from sub-atmospheric working pressure.

Vacuum suitability −0.9 bar Reversible flow

3. MPA Valve-Station Flow Planning

A machine builder selects a dual normally open function for an MPA valve station and needs a flow figure matched to the actual platform. The manufacturer lists different nominal flows for MPA-S, MPA-L and MPA-C installations. Keeping those conditions with the rating supports station planning alongside the valve's 14 mm size, through-hole mounting and documented mounting-torque limit.

Problem Solved

Platform-specific flow information gives the builder a relevant rating for the chosen valve station, avoiding an unconditional flow assumption when integrating the dual normally open function.

MPA-S / MPA-L / MPA-C Conditional flow ratings 0.65 Nm mounting limit

Additional information