Description
SICK IME18-08BNSZC0K NPN Inductive Proximity Sensor
Technical Overview
The SICK IME18-08BNSZC0K is an M18 inductive proximity sensor with an NPN normally open output and DC three-wire wiring. It detects metal targets without an optical path, with a nominal sensing range of 8 mm and an assured range of 6.48 mm. Target material must be considered using the documented reduction factors. The flush installation arrangement and M18 × 1 threaded nickel-plated brass housing support machine integration. The sensor provides 1,000 Hz switching and operates from 10–30 V DC, with an M12 four-pin male connector, a PA66 sensing face and IP67 protection.
Flush M18 inductive sensor with 8 mm nominal range, NPN normally open output, 1,000 Hz switching and M12 four-pin male connector.
Key Features
- Inductive proximity sensing of metal targets
- 8 mm nominal range; 6.48 mm assured range
- Flush installation; short M18 × 1 threaded housing
- NPN normally open output; DC three-wire wiring
- 1,000 Hz switching frequency
- 10–30 V DC operation; ≤10 mA no-load current
- Continuous output current ≤200 mA
- Nickel-plated brass housing; PA66 sensing face
- IP67; −25 to +75 °C operating range
- M12 four-pin male connector; two mounting nuts supplied
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Inductive proximity sensing of metal targets |
| Housing form | Metric cylindrical, short-body |
| Thread size | M18 × 1 |
| Housing diameter | 18 mm |
| Nominal sensing range Sn | 8 mm |
| Assured sensing range Sa | 6.48 mm |
| Installation type | Flush |
| Switching frequency | 1,000 Hz |
| Switching output | NPN |
| Output function | Normally open (NO) |
| Electrical wiring | DC 3-wire |
| Connection | Male connector M12, 4-pin |
| Power supply | 10–30 V DC |
| Residual ripple | ≤10% |
| Voltage drop | ≤2 V at maximum output current |
| Time delay before availability | ≤100 ms |
| Hysteresis | 5–15% |
| Reproducibility | ≤2% of Sr at constant supply and ambient temperature |
| Temperature drift | ±10% of Sr |
| Continuous output current | ≤200 mA |
| No-load current | ≤10 mA |
| Housing material | Brass, nickel-plated |
| Sensing face material | PA66 plastic |
| Housing length | 50 mm |
| Thread length | 33 mm |
| Maximum tightening torque | ≤40 Nm |
| Items supplied | 2 nickel-plated brass mounting nuts |
| IP rating | IP67 according to EN 60529 |
| Operating temperature | −25 to +75 °C |
| EMC | EN 60947-5-2 |
| Shock and vibration resistance | 30 g, 11 ms / 10–55 Hz, 1 mm |
| Reference material reduction factors | St37 steel: 1; stainless steel V2A/304: approximately 0.8; aluminum: approximately 0.45; copper/brass: approximately 0.4; reference values may vary |
| MTTFD | 1,735 years |
| Diagnostic coverage DCavg | 0% |
| UL file | NRKH.E181493 |
Industrial Applications
1. Confirming a metal part in a fixture
A machining fixture can place the sensor beside the expected location of a metal part so the target enters its assured sensing zone when seated. Flush installation allows mounting in the fixture face, and the NPN normally open output provides the presence signal. Target material must be considered using the documented reduction factors.
A contactless metal-presence signal helps the sequence controller identify an occupied fixture position before the next operation, avoiding a mechanical feeler pressing against the seated part.
2. Counting metal tabs on a rotating mechanism
A rotating mechanism can present separated metal tabs to the M18 sensing face and count each normally open output transition. The 1,000 Hz switching frequency supports repeated passages within the documented limits. Tab geometry, spacing, operating gap and material reduction factors must be qualified so consecutive targets produce distinct switching events.
Discrete tab passages provide the controller with a pulse count related to mechanism rotation, supporting cycle counting without an optical beam or contacting follower on the moving tabs.
3. Confirming a shuttle at a transfer position
A shuttle can carry a metal flag that enters the sensor’s local detection zone at a transfer position. The M18 thread and two supplied mounting nuts support fixed installation, while the normally open NPN signal reports the flag state. IP67 protection and the nickel-plated brass body support exposed machine placement.
A local position-confirmation signal helps the controller coordinate transfer sequencing when the metal flag reaches the monitored point, without a mechanical switch actuator following each shuttle movement.