SICK 1046711 LUT8U-11101 Luminescence Sensor

USD 1,211.60

375 nm UV luminescence sensor with 0–20 mm working range,PNP/NPN light-switching outputs,0–13 mA analog signal,2.5 kHz switching and manual adjustment.

SKU: SICK-1046711 Category:

Description

SICK LUT8

SICK LUT8U-11101 UV Luminescence Sensor

BrandSICK
Model IdentifierLUT8U-11101
Official Part Number1046711

Technical Overview

The SICK LUT8U-11101 is a luminescence sensor that detects fluorescent targets using a 375 nm ultraviolet LED and a 450–750 nm receiving range. Its 0–20 mm working range and ≤10 mm sensing distance from the lens front support placement of qualified marks. A vertical 2 ×6 mm spot and a receiving filter that blocks wavelengths up to 420 nm separate target fluorescence from shorter-wavelength background emission. Manual rotary sensitivity adjustment sets the switching threshold. Separate PNP and NPN light-switching outputs and a 0–13 mA analog output support external control and signal monitoring. Switching frequency is 2.5 kHz, with a 200 µs response. The zinc diecast housing is rated IP67.

375 nm UV luminescence sensor with0–20 mm working range,2 ×6 mm vertical spot,PNP/NPN switching,0–13 mA analog output and M12 five-pin plug.

Key Features

  • 375 nm ultraviolet LED;long-side light emission
  • 450–750 nm receiving range;filter blocks wavelengths≤420 nm
  • 0–20 mm working range;≤10 mm sensing distance from lens front
  • 2 ×6 mm vertical light spot
  • Separate PNP and NPN light-switching outputs;0–13 mA analog output
  • 2.5 kHz switching at1:1 light/dark ratio;200 µs response
  • Manual rotary sensitivity control
  • Green luminescence-intensity bar graph;yellow switching indicator
  • M12 five-pin plug;analog output on pin5
  • Zinc diecast IP67 housing;−10 to+55 °C operation

Detect qualified fluorescent marks with UV excitation,background-suppressing receiving filtration and external machine-control signals.

Technical Specification Matrix

ParameterValue
Functional principleUV luminescence detection of fluorescent targets
Housing formLarge
Light sourceUltraviolet LED
Wavelength375 nm
Light emissionLong housing side
Light spot size2 ×6 mm
Light spot directionVertical
Working range0–20 mm
Sensing distance≤10 mm from leading edge of lens
Receiving range450–750 nm
Receiving filterBlocks wavelengths≤420 nm to suppress shorter-wavelength background luminescence
Power supply12–30 V DC;short-circuit-protected supply network maximum8 A
Ripple<5 Vpp;supply voltage must remain within tolerances
Current consumption<100 mA without load
Switching outputPNP and NPN,separate outputs
Switching modeLight switching
Switching frequency2.5 kHz with light/dark ratio1:1
Response time200 µs
Output currentImax100 mA
Protection classII;reference voltage50 V DC
Circuit protectionSupply reverse-polarity protection;Q short-circuit protection;interference pulse suppression
ConnectionM12 five-pin plug
Connector adjustmentRotatable up to90°
Housing materialZinc diecast
Main body width30.4 mm
Main body height53 mm
Main body depth80 mm
MountingM5 threaded mounting holes,5.5 mm deep
IndicatorsYellow switching-output indicator;green bar graph with leftmost power-on LED
Operating temperature−10 to+55 °C
Storage temperature−25 to+75 °C
Shock loadIEC60068
IP ratingIP67
Physical Weight (kg)0.4
AdjustmentManual rotary sensitivity control
Analog output0–13 mA
Pin assignment1/BN=L+;3/BU=M;2/WH=Q NPN;4/BK=Q PNP;5/GY=QA analog;CD-312
NPN switching output voltageHIGH approximately supply voltage;LOW≤2 V
Bar graphLuminescence intensity independently of switching-threshold setting

Industrial Applications

1. Registering fluorescent marks on a moving web

A converting machine can move a qualified fluorescent registration mark and its background through the 2 ×6 mm vertical spot. The 375 nm UV source excites the mark and the receiver evaluates its visible emission. Manual sensitivity adjustment sets the mark/background threshold, and a compatible controller uses a switching transition as a timing reference within the 2.5 kHz switching condition.

Problem Solved

A fluorescence-derived timing event gives the external web controller a registration reference when the mark is distinguished by UV-excited emission, without a mechanical index contact touching the moving material.

Web registration 375 nm UV Vertical spot

2. Checking qualified fluorescent adhesive at an assembly point

An assembly station can present an adhesive containing a qualified fluorescent tracer at a defined inspection location within the 0–20 mm working range. The sensor evaluates fluorescence against the local background using its threshold adjustment. The switching signal lets external control equipment inspect local adhesive presence; the test addresses the monitored spot and does not measure bond strength or full coverage.

Problem Solved

A local fluorescence-presence condition lets the external inspection sequence flag a missing monitored adhesive spot without depending on a visible color difference or contacting the applied material.

Adhesive presence Fluorescent tracer Threshold adjustment

3. Monitoring fluorescent-signal strength during setup

A machine setup station can connect the 0–13 mA analog signal to compatible external analog equipment while a qualified fluorescent target and its background are presented. The green local bar graph also displays luminescence intensity independently of the switching threshold. The operator can compare the external signal and the switching condition while setting manual sensitivity.

Problem Solved

An intensity-related analog signal helps external setup equipment reveal changing fluorescence or background conditions without relying solely on whether the binary switching output has crossed its threshold.

0–13 mA analog Intensity bar graph Manual setup