Description
Festo MS2-LR-QS6-D6-AR-MPA-B Pressure Regulator
Technical Overview
The Festo MS2-LR-QS6-D6-AR-MPA-B is a size 2 directly actuated diaphragm pressure regulator with QS-6 connections at both ports. It regulates output pressure over 0.5–7 bar from a 1–8 bar operating supply and provides 350 l/min standard nominal flow. Secondary exhausting and return flow are included alongside the constant-output-pressure function. A pressure gauge with MPa indication and a detented rotary knob provide local reading and adjustment, with maximum pressure hysteresis of 0.25 bar. The 36.1 g reinforced-PA assembly supports front-panel, inline or accessory mounting in any position, with Class 6 cleanroom suitability and −5 to 50 °C environmental limits.
QS-6 diaphragm pressure regulator with 0.5–7 bar adjustment, MPa gauge, detent knob and 350 l/min standard nominal flow.
Key Features
- Size 2 MS-series directly actuated diaphragm regulator
- 0.5–7 bar pressure-regulation range; 1–8 bar operating pressure
- QS-6 pneumatic connections at both ports
- 350 l/min standard nominal flow to DIN 1343
- Constant output pressure with secondary exhausting
- Integrated return-flow function
- MPa pressure gauge and detented rotary knob
- 0.25 bar maximum pressure hysteresis
- Front-panel, inline or accessory mounting in any position
- 36.1 g reinforced-PA assembly; Class 6 cleanroom suitability and −5 to 50 °C ambient/media/storage range
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Size | 2 |
| Series | MS |
| Actuator lock | Rotary knob with detent |
| Mounting position | Any |
| Design | Directly actuated diaphragm regulator |
| Controller function | Output pressure constant; With secondary exhausting; With return flow function |
| Displayable units | MPa |
| Pressure gauge (ANALOG) or Pressure display (DIGITAL) | With pressure gauge |
| Operating pressure | 0.1 MPa...0.8 MPa; 1 bar...8 bar |
| Pressure regulation range | 0.5 bar...7 bar |
| Max. pressure hysteresis | 0.025 MPa; 0.25 bar; 3.625 psi |
| Standard nominal flow rate (standardised to DIN 1343) | 350 l/min |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4]; Inert gas |
| Corrosion resistance class CRC | 1 - Low corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Cleanroom suitability, measured according to ISO 14644-14 | Class 6 according to ISO 14644-1 |
| Storage temperature | -5 °C...50 °C |
| Media temperature | -5 °C...50 °C |
| Ambient temperature | -5 °C...50 °C |
| Physical Weight (kg) | 0.0361 |
| Type of mounting | Either:; Front panel mounting; Inline installation; With accessories |
| Pneumatic connection, port 1 | QS-6 |
| Pneumatic connection, port 2 | QS-6 |
| Note on materials | RoHS compliant |
| Material underneath cover | PA |
| Material seals | NBR |
| Material rotary knob | POM |
| Material spring | High-alloy steel |
| Material housing | Reinforced PA |
| Material membrane | NBR |
| Material valve stem | Wrought aluminium alloy; NBR |
Industrial Applications
1. Local Working-Pressure Adjustment at an Actuator
An assembly fixture needs a local pressure setting for one pneumatic working line. The diaphragm regulator places a 0.5–7 bar adjustment between a QS-6 inlet and QS-6 outlet, with a gauge showing the regulated condition. The detented knob supports setting the pressure at the point of use rather than making the whole machine supply use that same setting.
A local regulator gives the selected working line its own pressure adjustment and visible gauge reading, supporting a different pneumatic setting from the surrounding machine supply.
2. Reducing Regulated Pressure During Product Changeover
A machine operator changes a fixture to a lower regulated-pressure setting for the next product. The regulator includes secondary exhausting, providing a relief function on the regulated side as the setpoint is adjusted downward. Its pressure gauge gives a local indication of the resulting pressure, while the rotary knob detent forms part of the manual adjustment interface.
Secondary exhausting gives the downstream side a pressure-relief path during adjustment, while the gauge shows the regulated condition instead of leaving the operator to infer it from knob position.
3. Regulated Line with a Required Return-Flow Path
A pneumatic circuit needs forward pressure regulation while also permitting return flow through the same local regulator arrangement. This model explicitly includes a return-flow function alongside constant output pressure and secondary exhausting. Its QS-6 inlet and outlet interfaces make the connection arrangement clear, and the 350 l/min standard nominal flow rating provides a documented regulator characteristic for circuit selection.
The integrated return-flow function accommodates reverse flow in a line that also needs forward pressure regulation, combining those pneumatic functions in one compact regulator component.