Description
SICK WS/WE100L-E1131 NPN Laser Through-beam Sensor
Technical Overview
The SICK WS/WE100L-E1131 is a through-beam photoelectric sensor with separate sender and receiver units and a 650 nm visible red Class 1 laser. It specifies a 0–30 m sensing range and a 0–35 m maximum range, with a 30 mm light spot at 30 m. A 270° potentiometer adjusts sensitivity, and an L/D rotary switch selects light or dark switching for the receiver’s NPN output. Response is below 0.25 ms with a resistive load, and switching frequency is 2,000 Hz at a 1:1 light/dark ratio. Both units operate from 10–30 V DC with 2 m PVC cable connections; ABS/PC/POM housings, PMMA optics, M3 mounting holes and two supplied stainless steel brackets support IP65 installations.
Class 1 red-laser through-beam sensor with 0–30 m range, NPN output, 2,000 Hz switching, local sensitivity and L/D controls, and 2 m PVC cable connections.
Key Features
- Separate sender and receiver for through-beam detection
- 0–30 m sensing range; 0–35 m maximum range
- 650 nm visible red laser; Class 1
- Ø30 mm light spot at 30 m
- 270° sensitivity potentiometer; L/D rotary switching selector
- NPN output; ≤100 mA
- Response <0.25 ms with resistive load; 2,000 Hz at 1:1 light/dark ratio
- 2 m PVC cable connections
- M3 threaded mounting; two BEF-W100-A stainless steel brackets supplied
- IP65 ABS/PC/POM housings and PMMA optics; −10 to +50 °C operation
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Through-beam photoelectric sensing with separate sender and receiver |
| Housing design | Rectangular |
| Sensing range | 0–30 m |
| Maximum sensing range | 0–35 m |
| Light source | 650 nm visible red laser |
| Laser class | 1 |
| Light-source service life | Average 50,000 h at +25 °C |
| Light spot size | Ø10 mm at 10 m; Ø20 mm at 20 m; Ø30 mm at 30 m |
| Adjustment | 270° sensitivity potentiometer |
| Switching output | NPN |
| Switching mode | Light/dark switching, selected with L/D rotary switch |
| Signal voltage HIGH/LOW | Approximately supply voltage / <1.8 V |
| Output current | ≤100 mA |
| Response time | <0.25 ms with resistive load |
| Switching frequency | 2,000 Hz at light/dark ratio 1:1 |
| Power supply | 10–30 V DC; limit values in a short-circuit-protected network, maximum 8 A |
| Ripple | ±10%; remain within supply-voltage tolerances |
| Sender current consumption | ≤15 mA without load |
| Receiver current consumption | ≤20 mA without load |
| Connection | 2 m PVC cable connections |
| Conductor functions | Sender: BN=L+, BU=M (CD-047). Receiver: BN=L+, BU=M, BK=Q (CD-044) |
| Circuit protection | A: supply connections reverse-polarity protected; B: inputs and output reverse-polarity protected; D: outputs protected against overcurrent and short circuits |
| Housing material | ABS/PC/POM plastic |
| Optics material | PMMA plastic |
| IP rating | IP65 |
| Mounting | M3 threaded mounting holes; 25.4 mm spacing |
| Items supplied | Two BEF-W100-A stainless steel mounting brackets, grade 1.4301/304 |
| Operating temperature | −10 to +50 °C |
| Storage temperature | −40 to +70 °C |
| Indicators | Orange: switching output active; green: power on |
| Manufacturer special applications | Detecting small objects and objects moving at high speeds |
| MTTFD | 994 years |
| DCavg | 0% |
| Receiver cable | Three-wire, 2 m PVC; 0.18 mm² conductors |
| Cable handling | Do not bend below 0 °C |
Industrial Applications
1. Counting opaque components across a conveyor opening
A conveyor can carry separated opaque components between the sender and receiver. Each component interrupts the directly transmitted laser beam, and the receiver’s NPN output supplies transitions to external counting logic. The 270° potentiometer establishes working sensitivity, while setup verifies actual component coverage, alignment and transit timing against the spot size, response time and 2,000 Hz switching specification.
Beam-interruption transitions help an external counter register separated components across an opening, with a dedicated receiver evaluating light sent directly from the opposite side.
2. Monitoring continuity of an opaque material web
A material guide can hold an opaque web across the beam path between the sender and receiver. Continuous material blocks the transmitted beam, while a missing section allows light to reach the receiver. The rotary L/D selector sets the output convention for external web-loss logic. Setup checks the actual web opacity, beam coverage, alignment and sensitivity at the guide.
An interruption-state reference helps external process logic detect missing continuous material at the guide, using direct transmission rather than light reflected by the web surface.
3. Flagging prolonged occupancy at a transfer opening
A transfer opening can place the sender and receiver on opposite sides of a carton path. A carton blocks the beam as it enters, giving an external dwell timer a discrete occupancy condition. External logic compares the blocked interval with the expected transfer time and flags prolonged obstruction. Installation checks alignment, actual carton coverage and the selected light/dark switching convention.
A blocked-beam reference lets external timing logic identify a carton remaining at the opening beyond its transfer interval, helping locate a stalled movement.