Description
SICK GTB10-P4211 PNP BGS Photoelectric Sensor
Technical Overview
The SICK GTB10-P4211 is a background-suppression photoelectric sensor with a PNP switching output and a visible red PinPoint LED. Its maximum sensing range is 20–950 mm on a white reference target having 90% remission, with actual usable distance dependent on the target surface. The 625 nm LED produces an 8 mm light spot at 700 mm, and a five-turn potentiometer adjusts the sensing setting. Background suppression helps distinguish the intended target from more distant surfaces. Selectable light/dark switching, response of no more than 500 µs, 1,000 Hz operation, an M12 4-pin connector and IP67 plastic housing support machine integration.
PNP background-suppression sensor with 950 mm maximum reference-target range, 1,000 Hz switching, M12 4-pin connector and IP67 housing.
Key Features
- Background suppression for target detection ahead of distant surfaces
- 20–950 mm maximum range on 90% remission reference white
- 625 nm visible red PinPoint LED
- Ø 8 mm light spot at 700 mm
- Five-turn sensing adjustment
- PNP output; selectable light/dark switching
- Response ≤ 500 µs; 1,000 Hz switching
- 10–30 V DC; 20 mA current consumption
- M12 4-pin male connector
- IP67 ABS/PMMA housing; −30 to +60 °C operation
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Photoelectric proximity sensor with background suppression |
| Maximum sensing range | 20–950 mm on 90% remission white target (DIN 5033) |
| Light source | PinPoint LED, visible red light |
| Wavelength | 625 nm |
| Light spot size | Ø 8 mm at 700 mm |
| Adjustment | Potentiometer, 5 turns |
| Power supply | 10–30 V DC; short-circuit-protected network, max. 8 A |
| Residual ripple | < 5 Vpp; remain within supply-voltage limits |
| Current consumption | 20 mA |
| Switching output | PNP |
| Switching mode | Light/dark switching; selectable via selector |
| Output current | ≤ 100 mA |
| Response time | ≤ 500 µs with resistive load |
| Switching frequency | 1,000 Hz at light/dark ratio 1:1 |
| Connection | Male connector M12, 4-pin |
| Circuit protection | Supply/input/output reverse-polarity protection, interference suppression and output overcurrent/short-circuit protection |
| Protection class | III |
| Housing form | Rectangular |
| Housing material | ABS/PMMA plastic |
| IP rating | IP67 |
| EMC standard | EN 60947-5-2 |
| Operating temperature | −30 to +60 °C |
| Storage temperature | −40 to +70 °C |
| UL file | NRKH.E348498 & NRKH7.E348498 |
| Conditional standard | UL325 when used with a sturdy protective hood, for example BEF-G10WSG (2071960) |
| MTTFD | 1,885 years |
| Diagnostic coverage DCavg | 0% |
| Dimensions L x W x H (cm) | 3.9 x 2 x 5 |
| Physical Weight (kg) | 0.035 |
Industrial Applications
1. Workpiece detection in front of a machine frame
An assembly fixture must detect an opaque workpiece without responding to a structure farther behind it. Background suppression separates the intended near target from more distant surfaces within the documented operating geometry. The 20–950 mm maximum range on a 90% remission white target sensing range and five-turn adjustment support a defined detection position, while the PNP output supplies the workpiece signal to the controller.
Distance-based background rejection reduces unwanted detections from the machine structure behind the fixture, giving the sequence controller a clearer indication that the intended workpiece occupies the sensing point.
2. Counting separated components on a conveyor
A narrow conveyor carrying separated components needs a switching event at each passing part. The sensor directs a red spot of approximately 8 mm diameter at 700 mm toward the detection point. Background suppression helps distinguish the raised components from a more distant belt surface, and the 1,000 Hz switching frequency supports repeated transitions within the specified operating limits.
A defined optical spot and background rejection help isolate component passages from the belt behind them, supporting repeatable count events without mechanical contact with the moving parts.
3. Checking tray seating before a handling cycle
A handling station can direct the sensor toward the expected edge of a seated opaque tray. The short sensing range establishes a local presence check, while background suppression limits responses from surfaces farther away when the tray is absent. The response of no more than 500 µs supplies a prompt input transition, and selectable light/dark switching fits the machine sequence logic.
A contactless tray-position signal helps the controller distinguish an occupied pickup location from an empty station, supporting coordinated handling without a mechanical feeler at the tray edge.