Description
SICK GTE10-R3821 AC/DC Relay-output Energetic Sensor
Technical Overview
The SICK GTE10-R3821 is an energetic photoelectric proximity sensor with an electrically isolated SPDT relay output. Reference-white sensing spans 40–1,400 mm, with a 20–2,000 mm maximum range and shorter ranges for gray and black targets. Its 850 nm infrared LED produces a 57 mm spot at 1,500 mm, and a 270° potentiometer adjusts sensitivity. The device operates from 24–240 V AC/DC with ±10% supply tolerance and consumes no more than 2.5 VA. Response is no more than 10 ms, with 20 Hz switching at a 1:1 light/dark ratio. A 2 m five-wire PVC cable connects power and relay contacts. ABS/PMMA construction provides IP67 protection. Relay load limits depend on switching voltage, and inductive or capacitive loads require suitable spark suppression.
Infrared energetic sensor with 40–1,400 mm reference-white sensing, 24–240 V AC/DC supply, isolated SPDT relay output and 2 m five-wire PVC cable.
Key Features
- Energetic photoelectric proximity sensing
- Reference white: 40–1,400 mm sensing; 20–2,000 mm maximum range
- 850 nm infrared LED; Ø57 mm spot at 1,500 mm
- 270° sensitivity potentiometer
- 24–240 V AC/DC supply, ±10%; ≤2.5 VA power consumption
- Electrically isolated SPDT relay; light/dark switching
- Maximum loads: 0.11 A at 250 V DC; 3 A at 30 V DC or 250 V AC
- ≤10 ms response; 20 Hz at 1:1 light/dark ratio
- 2 m five-wire PVC cable; 0.25 mm² conductors; IP67 ABS/PMMA construction
- −30 to +60 °C operation; UL range 0 to +50 °C
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Energetic photoelectric proximity sensor |
| Sensing range | 40–1,400 mm on 90% remission reference white (DIN 5033) |
| Maximum sensing range | 20–2,000 mm on 90% remission reference white (DIN 5033) |
| Reference-target ranges | Sensing / maximum: white 90% 40–1,400 / 20–2,000 mm; gray 18% 60–700 / 40–1,000 mm; black 6% 80–500 / 60–700 mm |
| Light source | Infrared LED |
| Wavelength | 850 nm |
| Light spot size | Ø57 mm at 1,500 mm |
| LED service life | Average 100,000 h at ambient +25 °C |
| Adjustment | Sensitivity potentiometer, 270° |
| Switching output | Relay, SPDT, electrically isolated |
| Switching mode | Light/dark switching |
| Switching load | Maximum 0.11 A at 250 V DC; 3 A at 30 V DC; 3 A at 250 V AC |
| Load suppression | Provide suitable spark suppression for inductive or capacitive loads |
| Response time | ≤10 ms |
| Switching frequency | 20 Hz at 1:1 light/dark ratio |
| Power supply | 24–240 V AC/DC, ±10% |
| Ripple | <10% |
| Power consumption | ≤2.5 VA |
| Connection | 2 m five-wire PVC cable; 0.25 mm² conductors; do not bend below 0 °C |
| Wire assignments | CD-163: BN=L/(+); BU=N/(−); WH, BK and GY are relay-contact leads |
| Circuit protection | C: interference suppression |
| Protection class | II; reference voltage 250 V AC |
| Housing material | Plastic, ABS/PMMA |
| IP rating | IP67 |
| Relay switching cycles | Minimum 100,000 cycles at 3 A |
| Usage category | DC-13 and AC-15 according to EN 60947-1 |
| EMC | EN 60947-5-2; EN 61000-6-3 (2011-09) |
| Interference emission | EN 61000-6-3 (2011-09); with DC supply, cable between source and sensor must be <30 m |
| Mounting | 4.2 mm diameter mounting holes |
| Indicators | Green: power on; yellow: received-light status |
| Operating temperature | −30 to +60 °C; UL: 0 to +50 °C |
| Storage temperature | −40 to +70 °C |
| UL file | NRKH.E348498 and NRKH7.E348498 |
| Physical Weight (kg) | 0.115 |
Industrial Applications
1. Checking a component at a loading fixture
A loading fixture can present an opaque component surface at a repeatable gap within the checked energetic sensing range. External sequencing logic reads the isolated relay contact after the component settles. Commissioning adjusts sensitivity using representative parts and checks target reflectance, empty-fixture return and the selected contact state, with the connected load kept within its voltage-specific rating.
A component-present reference helps external sequencing logic distinguish a loaded fixture from an empty position, using reflected infrared light and an isolated contact checked for the actual installation.
2. Counting separated loads on a slow conveyor
A slow conveyor can carry separated opaque loads past the reflected-light sensing point and feed relay transitions to external counting logic. Setup adjusts sensitivity using the expected load surfaces, checks background reflections and verifies that dwell times and load gaps suit the 10 ms response and 20 Hz switching conditions. The contact circuit also respects the voltage-specific switching loads and suppression requirements.
A load-passage reference helps external counting logic register separated items on a checked slow conveyor, using a relay interface matched to actual timing and contact-loading conditions.
3. Monitoring opaque strip presence at a feed station
A feed station can keep an opaque strip surface within the sensor’s adjusted energetic working gap while external process logic evaluates relay state for material presence. Commissioning checks actual surface remission, strip flutter and the empty-path background. Control timing accounts for the specified response and switching frequency, and the relay circuit uses suitable load suppression where required.
A strip-presence reference helps external process logic recognize loss of opaque material at the checked station, using adjusted reflected-light sensing and a properly loaded isolated relay contact.