Description
SICK UC4-13347 0–10 V Ultrasonic Sensor
Technical Overview
The SICK UC4-13347 measures object distance using ultrasonic echoes over a 20–150 mm operating range, with a separate 250 mm limiting range. One 0–10 V analog output provides a scaled distance signal; local teach-in starts at 21 mm and supports rising or falling output characteristics. The specified 24 ms response can increase by up to 200% because of subsequent analog smoothing, while output time is 8 ms. Internal temperature compensation reaches its optimum after approximately one minute with the standard aluminum bracket and mounting screws. The ABS housing has two LEDs, an M8 three-pin connector and IP65/IP67 protection. Above 50 °C, its rear surface must sit flat against a bracket.
20–150 mm ultrasonic sensor with one 0–10 V analog output, teach-in from 21 mm, temperature compensation and M8 three-pin connection.
Key Features
- 20–150 mm operating range; 250 mm limiting range
- Analog teach-in from 21 mm; rising or falling characteristics
- One 0–10 V analog output; 12-bit output resolution
- Load ≥100,000 Ω
- 24 ms response; subsequent smoothing may increase it by up to 200%
- 8 ms output time; typical 380 kHz acoustic frequency
- Temperature compensation; optimum after approximately one minute
- 15–30 V DC; ≤0.75 W without load; startup <300 ms
- Two LEDs; M8 three-pin male connector; M3 mounting threads
- IP65/IP67 ABS housing; above 50 °C rear must contact bracket flat
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Ultrasonic distance measurement |
| Operating range | 20–150 mm |
| Limiting range | 250 mm; distinct from operating range |
| Minimum teach distance | 21 mm |
| Detection area | Depends on target reflection, size and alignment; reference diagrams use aligned 100 × 100 mm plate and Ø10 mm bar |
| Resolution | ≥0.1 mm |
| Repeatability | ±0.15% of current measured value; minimum value ≥resolution |
| Measurement accuracy | ±1% of current measured value |
| Temperature compensation | Available; optimum after approximately 1 min; factory calibration uses standard aluminum bracket and mounting screws |
| Response time | 24 ms; subsequent analog smoothing may increase response time by up to 200% |
| Output time | 8 ms |
| Ultrasonic frequency | Typical 380 kHz; acoustic frequency |
| Analog output | 1 × 0–10 V; load ≥100,000 ω |
| Analog output resolution | 12 bit |
| Adjustment | Local analog teach-in; rising/falling output characteristics; teach-button deactivation and factory reset |
| Power supply | 15–30 V DC; limit values; reverse-polarity protected |
| Supply network requirement | Short-circuit protected network, maximum 8 A |
| Power consumption | ≤0.75 W without load |
| Initialization time | <300 ms |
| Indicators | Green: supply active; orange: object within analog scaling range |
| Connection | M8 three-pin male connector |
| Pin assignment | 1 BN=L+; 3 BU=M/0 V; 4 BK=QA analog output |
| Mounting | M3 threaded mounting holes |
| Multiple-sensor separation | Parallel >250 mm; opposite >1,300 mm |
| Sending axis | Straight |
| Housing material | ABS plastic |
| Transducer materials | Polyurethane foam and glass epoxy resin |
| IP rating | IP65/IP67 |
| Protection class | III |
| Operating temperature | −25 to +70 °C; above 50 °C rear surface must lie flat against a bracket |
| Storage temperature | −40 to +85 °C |
| MTTFD | 101 years |
| DCavg | 0% |
| Physical Weight (kg) | 0.01 |
Industrial Applications
1. Monitoring liquid surface position in a small vessel
A small vessel can present a sufficiently reflecting liquid surface inside the 20–150 mm operating range. Two analog scaling points are taught at distances of at least 21 mm, and external monitoring receives the 0–10 V signal. Actual surface movement, foam, alignment and receiver load are checked before selecting the span and matching the filtered response to the filling cycle.
A scaled surface-distance signal lets external filling control track the changing liquid position and compare it with process thresholds, helping maintain a useful fill indication as the surface moves.
2. Tracking a material loop near its guide
A material handling station can position a reflecting loop surface within the 20–150 mm operating range and teach a useful analog span from 21 mm onward. External feed control evaluates the 0–10 V distance signal to follow loop movement. Actual material echoes, alignment and motion are validated, and the response allowance includes any subsequent analog smoothing used by the application.
Continuous distance feedback gives external feed control a changing position reference for the material loop, helping it recognize movement toward the selected near or far process boundary.
3. Following the outer surface of a small roll
A winding station can mount the sensor toward a reflecting roll surface and keep that surface within its 20–150 mm operating range. The local teach button sets analog endpoints at distances of at least 21 mm. External winding control interprets the 0–10 V signal as surface distance and can derive a process estimate from the separately known roll geometry and sensor mounting position.
Surface-distance feedback supplies external winding control with a changing geometric reference, helping it estimate material build-up when the roll axis and sensor mounting position are known independently.