Description
SICK GTB2S-P1451 PNP Background Suppression Sensor
Technical Overview
The SICK GTB2S-P1451 is a miniature photoelectric proximity sensor with background suppression and a fixed PNP light-switching output. Sensing spans 25–90 mm on a 6% remission black reference target, while maximum range reaches 2–120 mm on 90% remission reference white. Its 640 nm red PinPoint LED produces a 3.5 mm spot at 50 mm. A three-turn potentiometer adjusts sensing distance. Response is below 0.6 ms with resistive load, with 800 Hz switching at a 1:1 light/dark ratio. The 10–30 V DC device uses a 2 m three-wire PVC cable and a maximum 50 mA output. Its ABS housing, PMMA optics and 3.2 mm mounting holes support IP67 installation.
Miniature background-suppression sensor with 25–90 mm black-target sensing, three-turn adjustment, fixed PNP light switching and a 2 m three-wire PVC cable.
Key Features
- Photoelectric proximity sensing with background suppression
- 25–90 mm sensing on a 6% remission black reference target
- 2–120 mm maximum range on 90% remission reference white
- 640 nm red PinPoint LED; Ø3.5 mm spot at 50 mm
- Three-turn sensing-range potentiometer
- PNP light switching, fixed; ≤50 mA output
- <0.6 ms response with resistive load; 800 Hz at 1:1 light/dark ratio
- 10–30 V DC; 20 mA without load; 2 m three-wire PVC cable
- ABS housing; PMMA optics; IP67; Ø3.2 mm mounting holes
- −25 to +50 °C operation; −40 to +75 °C storage
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Photoelectric proximity sensor with background suppression |
| Sensing range | 25–90 mm on a 6% remission black reference target |
| Maximum sensing range | 2–120 mm on 90% remission reference white (DIN 5033) |
| Light source | Visible red PinPoint LED |
| Wavelength | 640 nm |
| Light spot size | Ø3.5 mm at 50 mm |
| LED service life | Average 100,000 h at ambient +25 °C |
| Adjustment | Sensing-range potentiometer, three turns |
| Switching output | PNP |
| Switching mode | Light switching, fixed |
| Output current | ≤50 mA |
| Response time | <0.6 ms with resistive load |
| Switching frequency | 800 Hz at 1:1 light/dark ratio |
| Power supply | 10–30 V DC; limit values in a short-circuit-protected network, maximum 8 A |
| Ripple | <5 Vpp; remain within supply tolerances |
| Current consumption | 20 mA without load |
| Connection | 2 m three-wire PVC cable; do not bend below 0 °C |
| Cable diameter | Ø3 mm |
| Wire assignment | CD-043: BN=L+; BU=M; BK=Q |
| Circuit protection | A: supply reverse-polarity protection; C: interference suppression; D: outputs overcurrent and short-circuit protection |
| Housing material | ABS plastic |
| Optics material | PMMA plastic |
| IP rating | IP67 |
| Mounting | Ø3.2 mm mounting holes |
| Indicators | Green: supply voltage active; yellow: received-light status |
| Operating temperature | −25 to +50 °C |
| Storage temperature | −40 to +75 °C |
| UL file | NRKH.E181493 |
| MTTFD | 3,138 years |
| DCavg | 0% |
| Physical Weight (kg) | 0.0342 |
Industrial Applications
1. Confirming a component in an assembly nest
An assembly nest can present a component at a repeatable distance facing the sensor. Background suppression provides a switching condition from one mounting side, while the documented adjustment establishes detection for representative components. External inspection logic samples the output after the component settles. Setup verifies actual target reflectance, placement tolerance and background geometry before accepting the installed detection point.
A component-present reference helps external inspection logic distinguish an occupied assembly location from an empty nest, using commissioned target geometry and the documented adjustment method.
2. Counting separated components on a guide
A component guide can move separated parts through the optical sensing point and send switching transitions to external counting electronics. Commissioning establishes the working gap and adjustment using representative materials, including the darkest expected target. Part transit time and gaps are checked against the documented response and switching-frequency conditions before setting the counting logic.
A discrete optical passage signal helps external counting electronics register separated components, using a commissioned sensing point and timing conditions matched to the actual parts feed.
3. Confirming a carrier at its transfer stop
A transfer stop can bring a defined carrier surface into the sensor’s working distance. External sequencing logic reads the optical switching state after the carrier reaches its seated position. Setup uses the documented adjustment and verifies actual carrier reflectance, gap tolerance and background geometry, then confirms that the fixed light-switching behavior matches the connected process input.
A seated-carrier condition helps external sequencing logic coordinate the next transfer step, using a checked optical gap and switching behavior for the actual carrier surface.