Description
Festo MHE2-MS1H-5/2-M7 Direct-Acting Solenoid Valve
Technical Overview
The Festo MHE2-MS1H-5/2-M7 is a direct-acting, single-solenoid 5/2-way valve with mechanical spring reset and 90 l/min standard nominal flow. All five ports use M7 threads in a 10 mm-wide body with a 2 mm nominal passage. The 24 V DC coil uses holding-current reduction, with 6.5 W high-current and 1.625 W low-current phases, and connects through a two-pin plug. Specified switching times are 1.9 ms on and 1.7 ms off, with a 300 Hz maximum frequency subject to temperature restrictions. The 70 g coated die-cast zinc assembly has IP65 protection, through-hole mounting and a −0.9 to 8 bar operating range.
M7 direct-acting 5/2 valve with mechanical spring reset, 90 l/min nominal flow, 24 V DC actuation and 1.9 ms on/1.7 ms off switching.
Key Features
- Single-solenoid 5/2-way function with mechanical spring reset
- Direct-acting pressure-relief poppet construction; 2 mm nominal size
- M7 connections at supply, working and exhaust ports
- 90 l/min standard nominal flow to DIN 1343
- 10 mm body and 14 mm mounting grid; 4 mm minimum inter-valve spacing
- −0.9 to 8 bar operating range; non-reversible flow
- 1.9 ms on and 1.7 ms off switching, with +10%/−30% tolerances
- 300 Hz maximum switching frequency, subject to frequency-dependent temperature limits
- 24 V DC two-pin plug; 6.5 W high-current/1.625 W low-current coil phases
- 70 g coated zinc body, IP65, holding-current reduction and non-detenting manual override
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 5/2-way, single solenoid |
| Type of actuation | Electrical |
| Construction width | 10 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 90 l/min |
| pneumatic working port | M7 |
| Operating voltage | 24 V DC |
| Operating pressure | -0.09 MPa...0.8 MPa; -0.9 bar...8 bar; -13.05 psi...116 psi |
| Design | Pressure relief poppet valve |
| Type of reset | Mechanical spring |
| Degree of protection | IP65 |
| Approval | RCM; c UL us - Recognised (Oil) |
| CE mark (see declaration of conformity) | To EU EMC Directive; In accordance with EU RoHS Directive |
| UKCA marking (see declaration of conformity) | To UK instructions for EMC; To UK RoHS instructions |
| Nominal size | 2 mm |
| Mounting grid pitch | 14 mm |
| Minimum inter-valve spacing | Minimum distance between the valves is 4 mm |
| Exhaust-air function | Can be throttled |
| Sealing principle | Soft |
| Mounting position | Any |
| Manual override | Non-detenting |
| Type of piloting | Direct |
| Flow direction | Non-reversible |
| lap | Underlap |
| Reverse polarity protection | Bipolar |
| Additional functions | Spark arresting; Holding current reduction; Protective circuit |
| Max. switching frequency | 300 Hz |
| Switching time off | 1.7 ms |
| Switching time on | 1.9 ms |
| Tolerance switching time off | +10%/-30% |
| Tolerance switching time on | +10%/-30% |
| Switching time dispersion from 1 Hz | 0.2 ms |
| Duty cycle | 100% |
| Characteristic coil data | 24 V DC: low-current phase 1.625 W, high-current phase 6.5 W |
| Permissible voltage fluctuations | +/-10% |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6 |
| Restrictions for environmental and media temperature | As a function of switching frequency (see graph) |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Cleanroom suitability, measured according to ISO 14644-14 | Class 6 according to ISO 14644-1 |
| Media temperature | -5 °C...60 °C |
| Ambient temperature | -5 °C...60 °C |
| Max. tightening torque for fitting | 2 Nm |
| Physical Weight (kg) | 0.07 |
| Electrical connection | 2-pin; Plug |
| Type of mounting | With through-hole |
| Pneumatic connection, port 1 | M7 |
| Pneumatic connection, port 2 | M7 |
| Pneumatic connection, port 3 | M7 |
| Pneumatic connection, port 4 | M7 |
| Pneumatic connection, port 5 | M7 |
| Note on materials | RoHS compliant |
| Material seals | HNBR; NBR |
| Material housing | Die-cast zinc, coated |
| Material screws | Galvanised steel |
Industrial Applications
1. Double-Acting Cylinder Direction Control
A transfer fixture needs to alternate pressure and exhaust between the two chambers of a double-acting cylinder. The valve's single-solenoid 5/2 function provides the two routing states, with mechanical spring reset. M7 connections and 90 l/min standard nominal flow define the pneumatic interface, while a two-pin plug provides the 24 V DC electrical actuation interface.
The five-port routing function supplies the cylinder's directional pressure and exhaust paths, combining an electrical command and mechanical spring reset for the fixture's pneumatic sequence.
2. Exhaust-Flow Setup for a Pneumatic Mechanism
A pneumatic mechanism needs its exhaust path arranged to suit the intended motion behaviour. Festo specifies that this valve's exhaust can be throttled, allowing appropriate external flow-control components in the surrounding circuit. The −0.9 to 8 bar working range and non-reversible flow direction define the valve conditions, while the actuator load and installed restriction determine the resulting motion.
Throttleable exhaust permits flow-control elements to shape the connected mechanism's exhaust behaviour, providing a defined routing component for tuning the pneumatic motion in its intended flow direction.
3. Local Routing Checks during Commissioning
During machine commissioning, a technician needs to exercise the valve's pneumatic routing at the component before completing the sequence setup. The non-detenting manual override provides local actuation, while through-hole mounting locates the body in the assembly. Separate 1.9 ms on and 1.7 ms off specifications characterise component switching for the subsequent electrical sequence.
A local manual override lets the technician exercise the valve routing during setup, while the documented mounting and switching data support integration into the machine's pneumatic sequence.