Festo VMPA1-M1H-E-PI Solenoid Valve
Technical Overview
The Festo VMPA1-M1H-E-PI is a 10 mm, 5/3-way solenoid valve with a exhausted centre position and mechanical spring reset. Its soft-sealing piston-gate construction supports reversible flow and documented vacuum suitability across a −0.9 to 10 bar working range. Standard nominal flow is 240 l/min, also specified with a QS-6 arrangement, while a separate 3–8 bar pilot-pressure range governs actuation. At 24 V DC, component timings are 10 ms on, 35 ms off and 15 ms reversal. The 56 g die-cast aluminium valve has NBR seals, IP65 protection, signal indication and detenting/non-detenting override, with through-hole mounting.
10 mm 5/3 exhaust-centre valve with mechanical spring reset, 240 l/min nominal flow, 24 V DC actuation and separate 3–8 bar pilot requirement.
Key Features
- 5/3-way exhaust-centre function with mechanical spring reset
- 10 mm valve size and soft-sealed piston-gate design
- 240 l/min standard nominal flow, also specified with QS-6 arrangement
- 24 V DC operation with ±25% permissible voltage variation
- −0.9 to 10 bar working range and separate 3–8 bar pilot pressure
- Reversible flow direction and documented vacuum suitability
- 10 ms switch-on, 35 ms switch-off and 15 ms reversal times
- Signal indication and detenting/non-detenting manual override
- IP65 protection; 0.25 Nm maximum valve-mounting torque
- 56 g die-cast aluminium body with NBR seals; −5 to 50 °C ambient/media range
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 5/3 exhausted |
| Type of actuation | Electrical |
| Valve size | 10 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 240 l/min |
| Operating voltage | 24 V DC |
| Operating pressure | -0.09 MPa...1 MPa; -0.9 bar...10 bar |
| Design | Piston gate valve |
| Type of reset | Mechanical spring |
| Approval | c UL us - Recognised (Oil) |
| Degree of protection | IP65; To IEC 60529 |
| Sealing principle | Soft |
| Mounting position | Any |
| Manual override | Detenting; Non-detenting |
| Type of piloting | Piloted |
| Flow direction | Reversible |
| lap | Overlap |
| Signal status display | Yes |
| Pilot pressure | 0.3 MPa...0.8 MPa; 3 bar...8 bar |
| Suitability for vacuum | Yes |
| Standard nominal flow rate with QS-6 | 240 l/min |
| Switching time off | 35 ms |
| Switching time on | 10 ms |
| Switching time reversal | 15 ms |
| Max. positive test pulse with 0 signal | 400 µs |
| Max. negative test pulse with 1 signal | 200 µs |
| Permissible voltage fluctuations | +/-25% |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 1 - Low corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Storage temperature | -20 °C...40 °C |
| Media temperature | -5 °C...50 °C |
| Relative air humidity | Max. 90% at 40 °C |
| Ambient temperature | -5 °C...50 °C |
| Max. tightening torque for valve mounting | 0.25 Nm |
| Physical Weight (kg) | 0.056 |
| Type of mounting | With through-hole |
| Note on materials | RoHS compliant |
| Material seals | NBR |
| Material housing | Die-cast aluminium |
Industrial Applications
1. Direction Control for a Double-Acting Transfer Cylinder
A transfer fixture needs to drive a double-acting cylinder in either direction and exhaust its working paths in the centre position. The 5/3-way valve provides that three-position arrangement with mechanical spring reset. Its 240 l/min nominal flow and separate 3–8 bar pilot requirement define the component conditions, while tubing, restrictions and actuator loading determine the actual pressure decay and motion.
Three-position routing provides an exhaust path in the centre state, giving the circuit a defined intermediate condition for relieving the working connections between directional commands.
2. Vacuum-Circuit Path Switching
A handling circuit needs a directional valve whose working paths can operate below atmospheric pressure. This model is explicitly suitable for vacuum and permits working pressure down to −0.9 bar with reversible flow. A separate 3–8 bar pilot requirement supplies the actuation condition while the working circuit follows the selected vacuum and venting connections.
Documented vacuum suitability permits switching of sub-atmospheric working paths, while the separate pilot-pressure range defines the positive-pressure actuation needed for that vacuum circuit arrangement.
3. Valve-Station Commissioning
During assembly of a pneumatic valve station, technicians need to exercise routing states and correlate electrical commands with the installed valve. The detenting and non-detenting manual override provides local actuation, while signal indication makes the commanded condition visible. The 10 mm valve uses through-hole mounting with a specified 0.25 Nm maximum valve-mounting torque for installation.
Manual actuation and visible signal indication support local routing checks during commissioning, helping technicians relate the electrical command to the selected pneumatic path at the valve station.