Description
Festo CPE14-M1BH-5/3E-1/8 5/3-Way Exhausted-Centre Valve
Technical Overview
The Festo CPE14-M1BH-5/3E-1/8 is a 14 mm-wide 5/3-way solenoid valve with an exhausted centre and mechanical spring reset. Its piston gate design provides G1/8 working connections, 700 l/min standard nominal flow and internal piloting over a 3–8 bar operating range. The 24 V DC, 1.28 W coil connects through a two-pin interface, with 100% duty permitted in conjunction with holding-current reduction. Through-hole mounting, throttleable exhaust and non-detenting manual override support integration and commissioning. IP65 protection applies with a plug socket, and the specified ambient and media range is −5 to +50 °C.
14 mm-wide 5/3-way exhausted-centre valve with G1/8 ports, 24 V DC coil, mechanical spring reset and 700 l/min nominal flow.
Key Features
- 5/3-way directional function with exhausted centre
- 14 mm construction width and 6 mm nominal size
- 700 l/min standard nominal flow rate to DIN 1343
- G1/8 pneumatic ports 1, 2, 3, 4 and 5
- 3–8 bar operating pressure with internal piloting
- Mechanical spring reset; non-reversible flow direction
- 24 V DC, 1.28 W coil with two-pin electrical connection
- 100% duty only in conjunction with holding-current reduction
- 20 ms switch-on and 42 ms switch-off times
- IP65 with plug socket; −5 to +50 °C ambient/media range
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 5/3 exhausted |
| Type of actuation | Electrical |
| Construction width | 14 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 700 l/min |
| pneumatic working port | G1/8 |
| Operating voltage | 24 V DC |
| Operating pressure | 0.3 MPa...0.8 MPa; 3 bar...8 bar |
| Design | Piston gate valve |
| Type of reset | Mechanical spring |
| Approval | c UL us - Recognised (Oil) |
| Certificate issuing authority | UL MH19482 |
| Degree of protection | IP65; With plug socket; To IEC 60529 |
| Nominal size | 6 mm |
| Exhaust-air function | Can be throttled |
| Sealing principle | Soft |
| Mounting position | Any |
| Manual override | Detenting via accessory; Non-detenting |
| Type of piloting | Piloted |
| Pilot air supply | Internal |
| Flow direction | Non-reversible |
| Valve position code | Label holder |
| lap | Overlap |
| Switching time off | 42 ms |
| Switching time on | 20 ms |
| Duty cycle | 100% in conjunction with holding current reduction |
| Max. positive test pulse with 0 signal | 1200 µs |
| Max. negative test pulse with 1 signal | 900 µs |
| Characteristic coil data | 24 V DC: 1.28 W |
| Permissible voltage fluctuations | -15% / +10% |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Media temperature | -5 °C...50 °C |
| Ambient temperature | -5 °C...50 °C |
| Physical Weight (kg) | 0.12 |
| Electrical connection | 2-pin |
| Type of mounting | With through-hole |
| Pilot exhaust port 82 | M3 |
| Pilot exhaust port 84 | M3 |
| Pilot air port 12 | M3 |
| Pilot air port 14 | M3 |
| Pneumatic connection, port 1 | G1/8 |
| Pneumatic connection, port 2 | G1/8 |
| Pneumatic connection, port 3 | G1/8 |
| Pneumatic connection, port 4 | G1/8 |
| Pneumatic connection, port 5 | G1/8 |
| Note on materials | RoHS compliant |
| Material seals | NBR |
| Material housing | Die-cast aluminium |
Industrial Applications
1. Transfer Cylinder with an Exhausted Neutral State
A pneumatic transfer mechanism needs extension, retraction and a neutral state that vents its working lines. The 5/3-way exhausted-centre valve provides those three circuit states through G1/8 ports. Its mechanical spring reset returns the valve to centre when actuation is removed, while the machine mechanism determines the resulting cylinder and load movement.
The exhausted centre supplies a distinct neutral air-routing state that vents the working lines, complementing the two directional commands used by the transfer cylinder.
2. Gripper Air-Line Venting Between Sequences
A handling machine requires a valve state that vents both working lines of a double-acting gripper between defined process steps. The exhausted-centre 5/3-way function provides that connection state, while electrical commands select the two directional states. Through-hole mounting and a 14 mm construction width support installing the valve in a compact protected control location.
A vented neutral state changes both gripper air-line connections without adding a separate operating command for each line, supporting a defined pneumatic sequence between directional movements.
3. Reversible Air-Motor Circuit with Vented Neutral
A machine uses a suitable reversible pneumatic motor for a positioning or winding task. The 5/3-way arrangement supplies two directional air-routing commands and an exhausted-centre neutral state through G1/8 working ports. A two-pin 24 V DC electrical interface connects actuation to the control system; motor run-down and mechanical stopping remain properties of the complete motor and load arrangement.
One valve supplies forward, reverse and vented-neutral circuit states, linking electrical actuation to the air-routing commands required by a suitable reversible pneumatic motor.