Description
SICK IMB18-12NPSVC0S PNP IO-Link Inductive Sensor
Technical Overview
The SICK IMB18-12NPSVC0S is a standard-design M18 × 1 inductive proximity sensor for non-flush installation. Its nominal sensing range is 12 mm and assured range is 9.72 mm, with reference reduction factors for different target metals. A PNP normally-open output provides 1,000 Hz switching, while IO-Link V1.0 reports whether Sr and Sa have been reached. The 10–30 V DC device connects through an M12 four-pin male connector with gold-plated contact pins. A V2A stainless steel housing and LCP sensing face provide IP68/IP69K protection and coolant-lubricant resistance. The visual adjustment indicator assists positioning, operation spans −40 to +100 °C, and two toothed V2A mounting nuts are supplied.
Non-flush M18 inductive sensor with 12 mm nominal range, PNP normally-open output, IO-Link V1.0 and M12 four-pin connection.
Key Features
- Standard-design M18 × 1 housing; non-flush installation
- 12 mm nominal sensing range; 9.72 mm assured sensing range
- PNP normally-open output; DC three-wire connection
- 1,000 Hz switching; continuous output current ≤200 mA
- IO-Link V1.0, COM2; one-byte Sr/Sa approach-state process data
- M12 four-pin male connector with gold-plated contact pins
- 10–30 V DC; no-load current ≤10 mA
- V2A stainless housing and LCP sensing face; coolant-lubricant resistance
- Visual adjustment indicator; two toothed V2A mounting nuts
- IP68/IP69K; −40 to +100 °C operation
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Inductive proximity sensing |
| Housing design | Standard-design |
| Mounting thread | M18 × 1 |
| Housing diameter | Ø18 mm |
| Installation | Non-flush |
| Nominal sensing range Sn | 12 mm |
| Assured sensing range Sa | 9.72 mm |
| Switching frequency | 1,000 Hz |
| Switching output | PNP normally open |
| Electrical wiring | DC three-wire |
| Connection | M12 four-pin male connector with gold-plated contact pins |
| Communication interface | IO-Link V1.0; COM2, 38.4 kBaud |
| Process data | One byte: bit 0=Sr reached; bit 1=Sa reached |
| Power supply | 10–30 V DC |
| Ripple | ≤10% |
| Voltage drop | ≤2 V at maximum continuous current Ia |
| Continuous output current | ≤200 mA |
| No-load current | ≤10 mA |
| Hysteresis | 3–20% |
| Reproducibility | ≤2% of Sr at supply voltage UB and constant ambient temperature Ta |
| Temperature drift | ±10% of Sr |
| Circuit protection | Short-circuit protection; power-up pulse protection |
| Housing material | V2A stainless steel, DIN 1.4305 / AISI 303 |
| Sensing face material | LCP plastic |
| Special features | Coolant-lubricant resistance; visual adjustment indicator; temperature resistance |
| IP rating | IP68 according to EN 60529; IP69K according to ISO 20653:2013-03 |
| Operating temperature | −40 to +100 °C |
| Tightening torque | Typical 60 Nm with non-toothed nut side; typical 90 Nm with toothed nut side |
| Items supplied | Two V2A stainless steel mounting nuts with locking teeth; 24 mm across flats |
| Material reduction factors | Reference values, may vary: St37 steel 1; stainless V2A/304 approximately 0.7; aluminum approximately 0.43; copper approximately 0.37; brass approximately 0.43 |
| Installation diagram clearances | A=18 mm; B=45 mm; C=18 mm; D=36 mm; E=12 mm; F=96 mm; letters refer to manufacturer non-flush installation diagram |
| Shock and vibration resistance | 100 g / 2 ms / 500 cycles; 150 g / 1 million cycles; 10–55 Hz / 1 mm; 55–500 Hz / 60 g |
| EMC | EN 60947-5-2 |
| Protection class | III |
| UL file | E181493 |
| MTTFD | 1,971 years |
| DCavg | 0% |
| Housing length | 65 mm including connector, as drawn |
| Thread length | 39 mm |
| Pin assignment | CD-456: 1 BN=L+; 4 BK=NO/C; 2=not connected; 3 BU=M |
Industrial Applications
1. Confirming a clamp position beside a machining fixture
A machining fixture can present a metal clamp target to the non-flush sensing face at a controlled seated gap. Coolant-lubricant resistance and the V2A/LCP construction support a sensing location near the process. External sequencing logic reads the PNP normally-open state after the clamp settles, with setup accounting for mounting clearances, the assured range and target-material reduction factors.
A clamp-position reference helps external sequencing logic distinguish a seated metal target from an open fixture location, using an inductive sensor designed for coolant and lubricant zones.
2. Counting separated metal features on a moving carrier
A moving carrier can present separated metal features across the sensor face and send PNP output transitions to an external counter. The 1,000 Hz switching rating supports repeated transitions when feature width, spacing, gap and speed provide distinct detected and undetected intervals. Commissioning accounts for non-flush mounting clearances and the reduction factor of the actual target metal.
Inductive switching gives external counting logic a passage reference for separated metal features, helping track carrier events through distinct target and gap states.
3. Comparing target approach states during fixture setup
During fixture setup, an IO-Link master can read the one-byte process data while a representative metal target approaches its normal seated position. Bit 0 indicates that Sr has been reached and bit 1 indicates that Sa has been reached. These discrete approach states complement the local visual adjustment indicator when assessing the installed target gap and repeatability.
Separate Sr and Sa process bits help setup personnel distinguish approach states at the installed target position, supporting margin assessment without requiring a numeric distance value.