Description
Festo MFH-5-1/2 Solenoid Valve Body
Technical Overview
The Festo MFH-5-1/2 is a piloted, single-solenoid 5/2-way valve body with a poppet-seat design and mechanical spring reset. All five pneumatic ports use G1/2 connections, with 3700 l/min standard nominal flow across a 2–8 bar operating range. The F solenoid coil is ordered separately, so voltage and power depend on the selected coil. Detenting manual override and throttleable exhaust support circuit setup, with component switching times of 21 ms on and 150 ms off. The 1135 g die-cast aluminium body has NBR/TPE-U seals, an M5 pilot-exhaust port and manifold-rail or through-hole mounting.
G1/2 single-solenoid 5/2 valve body with mechanical spring reset, 3700 l/min nominal flow and separately ordered F coil.
Key Features
- Single-solenoid 5/2-way poppet-seat function
- Piloted electrical actuation with mechanical spring reset
- G1/2 connections at ports 1, 2, 3, 4 and 5
- 3700 l/min standard nominal flow to DIN 1343
- F solenoid coil and its electrical connection ordered separately
- 2–8 bar operating range and non-reversible flow direction
- 21 ms switch-on and 150 ms switch-off times
- Detenting manual override and throttleable exhaust
- 52 mm construction width, 69 mm mounting grid pitch and M5 pilot exhaust port 84
- 1135 g die-cast aluminium body with NBR/TPE-U seals; manifold-rail or through-hole mounting
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 5/2-way, single solenoid |
| Type of actuation | Electrical |
| Construction width | 52 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 3700 l/min |
| pneumatic working port | G1/2 |
| Operating voltage | Via solenoid coil, must be ordered separately |
| Operating pressure | 0.2 MPa...0.8 MPa; 2 bar...8 bar |
| Design | Poppet seat |
| Type of reset | Mechanical spring |
| Approval | c UL us - Recognised (Oil) |
| Degree of protection | IP65 |
| Nominal size | 14 mm |
| Mounting grid pitch | 69 mm |
| Exhaust-air function | Can be throttled |
| Sealing principle | Soft |
| Mounting position | Any |
| Manual override | Detenting |
| Type of piloting | Piloted |
| Flow direction | Non-reversible |
| lap | Underlap |
| b value | 0.32 |
| Switching time off | 150 ms |
| Switching time on | 21 ms |
| Max. positive test pulse with 0 signal | 2200 µs |
| Max. negative test pulse with 1 signal | 3700 µs |
| Characteristic coil data | See solenoid coil, to be ordered separately |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Corrosion resistance class CRC | 1 - Low corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Storage temperature | -20 °C...60 °C |
| Media temperature | -10 °C...60 °C |
| Ambient temperature | -5 °C...40 °C |
| Physical Weight (kg) | 1.135 |
| Electrical connection | Via F coil, to be ordered separately |
| Type of mounting | Either:; On manifold rail; With through-hole |
| Pilot exhaust port 84 | M5 |
| Pneumatic connection, port 1 | G1/2 |
| Pneumatic connection, port 2 | G1/2 |
| Pneumatic connection, port 3 | G1/2 |
| Pneumatic connection, port 4 | G1/2 |
| Pneumatic connection, port 5 | G1/2 |
| Note on materials | RoHS compliant |
| Material seals | NBR; TPE-U(PU) |
| Material housing | Die-cast aluminium |
Industrial Applications
1. Double-Acting Cylinder Direction Control
A transfer fixture needs to alternate pressure and exhaust between the two chambers of a double-acting cylinder. The valve's single-solenoid 5/2 function provides the two routing states, with mechanical spring reset. G1/2 connections and 3700 l/min standard nominal flow define the pneumatic interface, while a separately ordered F coil establishes the electrical actuation configuration.
The five-port routing function supplies the cylinder's directional pressure and exhaust paths, combining an electrical command and mechanical spring reset for the fixture's pneumatic sequence.
2. Exhaust-Flow Setup for a Pneumatic Mechanism
A pneumatic mechanism needs its exhaust path arranged to suit the intended motion behaviour. Festo specifies that this valve's exhaust can be throttled, allowing appropriate external flow-control components in the surrounding circuit. The 2–8 bar working range and non-reversible flow direction define the valve conditions, while the actuator load and installed restriction determine the resulting motion.
Throttleable exhaust permits flow-control elements to shape the connected mechanism's exhaust behaviour, providing a defined routing component for tuning the pneumatic motion in its intended flow direction.
3. Local Routing Checks during Commissioning
During machine commissioning, a technician needs to exercise the valve's pneumatic routing at the component before completing the sequence setup. The detenting manual override provides local actuation, while manifold-rail or through-hole mounting locates the body in the assembly. Separate 21 ms on and 150 ms off specifications characterise component switching for the subsequent electrical sequence.
A local manual override lets the technician exercise the valve routing during setup, while the documented mounting and switching data support integration into the machine's pneumatic sequence.