Description
Festo MFH-5-1/4-EX Solenoid Valve Body
Technical Overview
The Festo MFH-5-1/4-EX is a 5/2-way single-solenoid valve body using a poppet-seat design and mechanical spring reset. Its F solenoid coil is ordered separately, so electrical voltage and coil characteristics depend on that selection. G1/4 connections provide 1000 l/min standard nominal flow across a 2.2–8 bar working range, with non-reversible flow and throttleable exhaust. The 30.5 mm-wide body has a 32 mm mounting grid pitch, 9 ms switch-on and 29 ms switch-off times. Its 290 g die-cast aluminium construction includes NBR seals, detenting manual override and IP65 protection, with a −5 to +40 °C ambient and media range.
G1/4 5/2-way valve body with mechanical spring reset, 1000 l/min nominal flow and separately ordered F solenoid coil.
Key Features
- 5/2-way single-solenoid function with mechanical spring reset
- F coil ordered separately; operating voltage depends on the coil
- Poppet-seat design with 7 mm nominal size
- G1/4 pneumatic connections and 1000 l/min nominal flow
- 2.2–8 bar operating pressure with non-reversible flow
- 9 ms switch-on and 29 ms switch-off times
- 30.5 mm construction width and 32 mm mounting grid pitch
- Detenting manual override and manifold-rail or through-hole mounting
- Manufacturer body markings Ex h IIC T4 Gb and Ex h IIIC T130°C Db
- 290 g product weight, IP65 protection and −5 to +40 °C ambient/media range
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 5/2-way, single solenoid |
| Type of actuation | Electrical |
| Construction width | 30.5 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 1000 l/min |
| pneumatic working port | G1/4 |
| Operating voltage | Via solenoid coil, must be ordered separately |
| Operating pressure | 0.22 MPa...0.8 MPa; 2.2 bar...8 bar |
| Design | Poppet seat |
| Type of reset | Mechanical spring |
| CE mark (see declaration of conformity) | To EU Explosion Protection Directive (ATEX) |
| UKCA marking (see declaration of conformity) | To UK EX instructions |
| Explosion protection certification outside the EU | EPL Db (GB); EPL Gb (GB) |
| ATEX category gas | II 2G |
| ATEX category dust | II 2D |
| Explosion ignition protection type for gas | Ex h IIC T4 Gb |
| Explosion ignition protection type for dust | Ex h IIIC T130°C Db |
| Explosion ambient temperature | -5°C <= Ta <= +40°C |
| Degree of protection | IP65 |
| Nominal size | 7 mm |
| Mounting grid pitch | 32 mm |
| Exhaust-air function | Can be throttled |
| Sealing principle | Soft |
| Mounting position | Any |
| Manual override | Detenting |
| Type of piloting | Piloted |
| Flow direction | Non-reversible |
| lap | Underlap |
| b value | 0.19 |
| C value | 4.49 l/sbar |
| Switching time off | 29 ms |
| Switching time on | 9 ms |
| Max. positive test pulse with 0 signal | 2200 µs |
| Max. negative test pulse with 1 signal | 3700 µs |
| Characteristic coil data | See solenoid coil, to be ordered separately |
| Explosion protection | Zone 1 (ATEX); Zone 1 (UKEX); Zone 2 (ATEX); Zone 21 (ATEX); Zone 21 (UKEX); Zone 22 (ATEX) |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Corrosion resistance class CRC | 1 - Low corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Storage temperature | -20 °C...60 °C |
| Media temperature | -5 °C...40 °C |
| Ambient temperature | -5 °C...40 °C |
| Physical Weight (kg) | 0.29 |
| Electrical connection | Via F coil, to be ordered separately |
| Type of mounting | Either:; On manifold rail; With through-hole |
| Breather connection | M3 |
| Pilot exhaust port 84 | M5 |
| Pneumatic connection, port 1 | G1/4 |
| Pneumatic connection, port 2 | G1/4 |
| Pneumatic connection, port 3 | G1/4 |
| Pneumatic connection, port 4 | G1/4 |
| Pneumatic connection, port 5 | G1/4 |
| Note on materials | RoHS compliant |
| Material seals | NBR |
| Material housing | Die-cast aluminium |
Industrial Applications
1. Reciprocating Fixture Cylinder Control
An assembly fixture moves a suitable double-acting cylinder between its working and return positions. The 5/2-way valve body supplies the two directional air-routing states, with mechanical spring reset and G1/4 connections. A separately selected F coil provides electrical actuation, while the 1000 l/min nominal flow and 2.2–8 bar working range characterize the pneumatic valve used in the cylinder circuit.
The directional body supplies advance and return routing for the cylinder circuit, while mechanical reset and separate coil selection define its pneumatic and electrical actuation arrangement.
2. Timed Product-Diverter Commands
A packaging machine commands a pneumatic diverter between two product routes and needs documented valve-response characteristics. This body specifies 9 ms switch-on and 29 ms switch-off times, with a 5/2 directional function and mechanical spring reset. The selected F coil supplies the electrical interface; the actual diverter travel time also depends on its actuator, tubing and mechanical load.
Published component switching times support evaluation of the diverter command sequence, while the 5/2 function provides the two pneumatic routing states required by the actuator circuit.
3. Grouped Valve Installation with Separate Coil Selection
A machine builder groups directional valves in a pneumatic control station and chooses the electrical coils to match the installation. This body supports manifold-rail or through-hole mounting, with a 30.5 mm width and 32 mm mounting pitch. Its separate F-coil arrangement keeps the electrical selection explicit, while detenting manual override provides the documented local actuation method during commissioning.
Defined mounting and spacing organize the pneumatic control station, while separate F-coil selection matches the electrical actuation hardware without changing the identified valve-body configuration.