Festo VUVG-B18-B52-ZT-F-1T1L 5/2-Way Solenoid Valve
Technical Overview
The Festo VUVG-B18-B52-ZT-F-1T1L is an 18 mm double-solenoid valve with a 5/2-way function and flange working connection for manifold installation. External pilot air at 1.5–8 bar operates the piston gate valve independently of its −0.9 to 10 bar working circuit. The standard nominal flow rate is 1000 l/min, with reversible flow direction, a 15 ms reversal time and a maximum switching frequency of 3 Hz. The valve operates at 24 V DC through an E-box; its coil data separately specify 22 V DC and 1.0 W. LED indication, manual override and IP65/IP67 protection support machine integration.
18 mm 5/2-way double-solenoid flange valve with external piloting, 1000 l/min nominal flow and a 24 V DC E-box interface.
Key Features
- 5/2-way double-solenoid directional function
- 18 mm valve size with flange working connection
- 1000 l/min standard nominal flow rate to DIN 1343
- −0.9 to 10 bar working pressure with external pilot air
- 1.5–8 bar pilot pressure; reversible flow direction
- 24 V DC operation via E-box; coil data 22 V DC, 1.0 W
- 15 ms reversal time; 3 Hz maximum switching frequency
- 100% duty cycle and LED signal indication
- Detenting/non-detenting manual override; throttleable exhaust
- IP65/IP67 protection and −5 to +60 °C ambient/media range
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 5/2-way, double solenoid |
| Type of actuation | Electrical |
| Valve size | 18 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 1000 l/min |
| pneumatic working port | Flange |
| Operating voltage | 24 V DC |
| Operating pressure | -0.09 MPa...1 MPa; -0.9 bar...10 bar |
| Design | Piston gate valve |
| Approval | c UL us - Recognised (Oil) |
| Degree of protection | IP65; IP67 |
| Exhaust-air function | Can be throttled |
| Sealing principle | Soft |
| Mounting position | Any |
| Manual override | Detenting; Non-detenting |
| Type of piloting | Piloted |
| Pilot air supply | External |
| Flow direction | Reversible |
| lap | Overlap |
| Signal status display | LED |
| Pilot pressure | 0.15 MPa...0.8 MPa; 1.5 bar...8 bar |
| Max. switching frequency | 3 Hz |
| Switching time reversal | 15 ms |
| Duty cycle | 100% |
| Max. positive test pulse with 0 signal | 1600 µs |
| Max. negative test pulse with 1 signal | 3000 µs |
| Characteristic coil data | 22 V DC: 1.0 W |
| Permissible voltage fluctuations | +/-10% |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Media temperature | -5 °C...60 °C |
| Pilot medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Ambient temperature | -5 °C...60 °C |
| Physical Weight (kg) | 0.145 |
| Electrical connection | Via E-box |
| Type of mounting | On manifold rail |
| Note on materials | RoHS compliant |
| Material seals | HNBR; NBR |
| Material housing | Wrought aluminium alloy |
Industrial Applications
1. Reciprocating Part-Transfer Cylinder
An assembly machine uses a double-acting cylinder to transfer a component between two positions. The 5/2-way valve alternates pressure and exhaust between the working lines through a flange interface. Its 18 mm size and manifold-rail mounting support a grouped pneumatic control assembly, while the E-box provides the electrical connection and LEDs show the signal state during commissioning.
Directional switching supplies the two pneumatic states needed for cylinder extension and retraction, while flange and manifold mounting group the transfer circuit with adjacent valve functions.
2. Pneumatic Gripper Open-and-Close Sequencing
A handling unit uses a double-acting gripper whose working pressure is set separately from the valve actuation supply. External pilot air at 1.5–8 bar operates the double-solenoid 5/2-way valve independently of the working circuit. This arrangement supports a gripper circuit in which directional control remains supplied by a separate pilot-air connection.
Separating pilot air from working pressure allows the valve actuation supply and gripper pressure circuit to be arranged independently, while electrical commands select the directional state.
3. Two-Position Product Diverter Actuation
A packaging conveyor uses a pneumatic actuator to move a product diverter between two routes. The valve reverses the actuator air connections through its 5/2-way circuit, with a 15 ms specified reversal time. The maximum switching frequency of 3 Hz provides a concrete valve limit for planning directional commands alongside the actuator and load response.
Documented reversal timing and switching frequency support planning the diverter commands, while the 5/2-way valve supplies the directional air routing required by the actuator.