Description
SICK WTB26I-24161420A00 IO-Link Infrared Background-Suppression Sensor
Technical Overview
The SICK WTB26I-24161420A00 is an infrared photoelectric proximity sensor with background suppression, a 30–3,000 mm white-target field and a 180–3,000 mm adjustable switching threshold. Its recommended range for best performance is 200–1,000 mm. The documented black-target example requires 190 mm separation from a white background at a set distance of 1,000 mm. BluePilot Teach-Turn sets the sensing range, while IO-Link configures parameters and Base logics functions. Complementary push-pull outputs provide 200 Hz general switching with a response of ≤2.5 ms. The 10–30 V DC device uses an M12 four-pin connector, VISTAL housing, PMMA front screen and IP66/IP67/IP69 protection.
Infrared background-suppression sensor with 200–1,000 mm recommended range, complementary push-pull outputs, IO-Link and M12 four-pin connection.
Key Features
- Background suppression; 30–3,000 mm range on 90% remission white
- 200–1,000 mm recommended range; 180–3,000 mm adjustable threshold
- 850 nm infrared LED
- BluePilot Teach-Turn and blue sensing-range indication
- Two complementary push-pull PNP/NPN outputs; ≤100 mA
- General response ≤2.5 ms; 200 Hz at 1:1 light/dark ratio
- IO-Link V1.1, COM2 and Base logics Smart Task functions
- Device-status and quality-of-teach diagnosis
- M12 four-pin male connector; Ø5.2 mm mounting holes
- VISTAL housing and connector, PMMA front screen; IP66/IP67/IP69
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Photoelectric proximity sensing with background suppression |
| Sensing range | 30–3,000 mm on 90% remission white reference, DIN 5033 |
| Adjustable background-suppression threshold | 180–3,000 mm |
| Recommended sensing range | 200–1,000 mm for best performance |
| Target-dependent viewing ranges | Black 6%: 100–1,200 mm; gray 18%: 75–1,800 mm; white 90%: 30–3,000 mm; adjustable threshold begins at 180 mm |
| Background separation example | At set sensing range 1,000 mm, a black 6% remission target requires 190 mm minimum separation to a white 90% remission background |
| Light source | Infrared LED, 850 nm; point-shaped spot |
| Adjustment | BluePilot Teach-Turn for sensing range; IO-Link for sensor parameters and Smart Task functions |
| Indicators | Blue: sensing-range indication; green steady: power, flashing: IO-Link; yellow on: object present, off: object absent |
| Default black-wire function | Pin 4 BK: light-switching output, object present → HIGH; IO-Link communication C |
| Default white-wire function | Pin 2 WH: dark-switching output, object present → LOW |
| Conductor functions | CD-390: 1 BN=L+; 3 BU=M; 4 BK=QL1/IO-Link C; 2 WH=multifunction output |
| Response time | ≤2.5 ms, signal transit with resistive load in switching mode |
| Response-time repeatability | 150 µs |
| Switching frequency | 200 Hz at 1:1 light/dark ratio |
| Connection | M12 four-pin male connector |
| Housing material | VISTAL plastic |
| Smart Task switching frequency | SIO Logic: 200 Hz; IO-Link: 200 Hz |
| Smart Task response time | SIO Logic: 2.5 ms; IO-Link: 2.5 ms |
| Smart Task repeatability | SIO Logic: 300 µs; IO-Link: 400 µs |
| Diagnosis | Device status; quality of teach |
| Squint angle | <±1.0° at ambient +23 °C |
| LED photobiological classification | Free group; EN 62471:2008-09 / IEC 62471:2006, modified |
| Average LED service life | 100,000 h at ambient +25 °C |
| Communication interface | IO-Link V1.1; COM2, 38.4 kBaud |
| IO-Link cycle time | 2.3 ms |
| Process data | 16 bit: bit 0=QL1; bit 1=QL2; bits 2–15 empty |
| IO-Link identification | Vendor ID 26; Device ID 0x800238 / 8389176 |
| Compatible master port | Type A; SIO mode supported |
| Power supply | 10–30 V DC, limit values |
| Ripple | ≤5 Vpp |
| Usage categories | DC-12 and DC-13 to EN 60947-5-2 |
| Current consumption | ≤30 mA without load at 24 V DC |
| Protection class | III |
| Switching outputs | Two complementary push-pull PNP/NPN outputs |
| Switching mode | Light/dark switching; pin functions configurable via IO-Link |
| PNP signal voltage HIGH/LOW | Approximately supply voltage −2.5 V / 0 V |
| NPN signal voltage HIGH/LOW | Approximately supply voltage / <2.5 V |
| Output current | ≤100 mA |
| Output circuit protection | Reverse-polarity, overcurrent and short-circuit protection |
| Output connection restriction | A switching output must not be connected to another output |
| Housing design | Rectangular |
| Front screen material | PMMA plastic |
| Mounting holes | Ø5.2 mm |
| Maximum fixing-screw torque | 1.3 Nm |
| IP rating | IP66/IP67/IP69 to EN 60529 |
| IP69 designation note | Manufacturer states IP69 replaces IP69K to ISO 20653:2013-03 |
| Operating temperature | −40 to +60 °C |
| Storage temperature | −40 to +75 °C |
| Relative humidity | 35–95%, non-condensing |
| Shock resistance, 11 ms | 50 g; 25 positive and 25 negative shocks per X/Y/Z axis, 150 total; EN 60068-2-27 |
| Shock resistance, 6 ms | 50 g; 5,000 positive and 5,000 negative shocks per X/Y/Z axis, 30,000 total; EN 60068-2-27 |
| Vibration resistance | 10–2,000 Hz; 0.5 mm amplitude / 10 g; 20 sweeps per X/Y/Z axis at 1 octave/min; EN 60068-2-6 |
| EMC | EN 60947-5-2 |
| Cleaning-agent resistance | ECOLAB |
| UL files | NRKH.E181493 and NRKH7.E181493 |
| MTTFD | 626 years |
| DCavg | 0% |
| Mission time | 20 years |
| Smart Task | Base logics |
| Smart Task logic functions | Direct, AND, OR, window and hysteresis |
| Smart Task timer functions | Deactivated, switch-on delay, off delay, ON and OFF delay, impulse (one shot) |
| Smart Task inverter | Available |
| Male connector material | VISTAL plastic |
| Physical Weight (kg) | 0.08 |
Industrial Applications
1. Checking a dark part ahead of a bright fixture background
A fixture can present a dark part in front of a white background and use the adjusted suppression threshold to distinguish the part from the farther surface. BluePilot Teach-Turn establishes the working distance with representative material. The manufacturer’s reference example specifies a minimum separation of 190 mm behind a 6% remission black object at a set distance of 1,000 mm when the background has 90% remission.
An adjusted background-suppressed condition gives external inspection logic a dark-part presence reference, helping identify an empty fixture without responding to its farther bright surface.
2. Applying sensor parameters with a machine recipe
A machine processing different target presentations can store sensor parameters in its external recipe system and write them through IO-Link when the product setup changes. The interface configures sensor parameters and Smart Task functions, while quality-of-teach diagnosis supplies setup information. Local blue sensing-range indication supports a check with the representative target before the machine resumes its sequence.
Digital parameter access helps external recipe control apply the intended sensor setup and review teaching information, supporting repeatable configuration when the presented product changes.
3. Qualifying sustained occupancy at a transfer nest
A transfer nest can use the infrared target condition to detect an item that remains after its expected movement. A configured Base logics switch-on delay qualifies sustained occupancy, and external sequencing uses the resulting event to hold upstream release. Timing assessment uses the separate Smart Task response and switching-frequency specifications for the selected SIO Logic or IO-Link operating mode.
Sensor-side occupancy qualification gives external sequencing a retained-item event, helping separate a normal brief passage from a nest that remains occupied after transfer.