SICK 1218666 IO-Link Background Suppression Photoelectric Sensor

USD 231.40

WTB26P-24161120A00 combines 30–1,600 mm reference-white sensing, BluePilot Teach-Turn adjustment, complementary push-pull outputs and IO-Link V1.1.

SKU: SICK-1218666 Category:

Description

SICK W26

SICK WTB26P-24161120A00 IO-Link Background Suppression Sensor

BrandSICK
Model IdentifierWTB26P-24161120A00
Official Part Number1218666

Technical Overview

The SICK WTB26P-24161120A00 is a photoelectric proximity sensor with background suppression and a 30–1,600 mm sensing range on 90% remission reference white. BluePilot Teach-Turn adjustment sets the sensing distance, with an adjustable background-suppression threshold of 180–1,600 mm and a recommended 200–600 mm working region for best performance. A 635 nm visible red PinPoint LED produces a 7 mm spot at 700 mm. Two complementary push-pull PNP/NPN outputs provide light/dark switching, and IO-Link V1.1 configures parameters and Smart Task functions. The four-pin M12 connection, VISTAL housing, PMMA front screen and IP66/IP67/IP69 protection support machine installation from −40 to +60 °C.

IO-Link background-suppression sensor with 30–1,600 mm reference-white sensing, BluePilot Teach-Turn adjustment, complementary push-pull outputs and M12 connection.

Key Features

  • Background suppression; 30–1,600 mm sensing on 90% remission reference white
  • Adjustable background-suppression threshold 180–1,600 mm; recommended working region 200–600 mm
  • 635 nm visible red PinPoint LED; Ø7 mm spot at 700 mm
  • BluePilot Teach-Turn range setting and blue sensing-range indicator
  • Two complementary push-pull PNP/NPN outputs; light/dark switching; maximum 100 mA
  • IO-Link V1.1 COM2, 38.4 kBaud; 2.3 ms cycle; SIO support
  • ≤500 µs response and 1,000 Hz in basic switching mode; Smart Task timing differs
  • Smart Task base logic, timer functions and inverter; configuration through IO-Link
  • M12 four-pin male connector; 10–30 V DC; ≤30 mA without load at 24 V
  • VISTAL housing and connector; PMMA front screen; IP66/IP67/IP69; −40 to +60 °C operation

Set reflected-light detection with BluePilot and configure parameters or Smart Task logic through IO-Link, using complementary push-pull switching outputs.

Technical Specification Matrix

ParameterValue
Functional principlePhotoelectric proximity sensor with background suppression
Sensing range30–1,600 mm on 90% remission reference white, DIN 5033
Adjustable switching threshold180–1,600 mm for background suppression
Recommended working range200–600 mm for best performance
Background separation example40 mm minimum between black 6% target at set distance 600 mm and white 90% background
Light sourceVisible red PinPoint LED; point-shaped spot
Wavelength635 nm
Light spot sizeØ7 mm at 700 mm
Squint angle<±1.0° at +23 °C
LED risk groupFree group; EN 62471:2008-09 / IEC 62471:2006, modified
LED service lifeAverage 100,000 h at +25 °C
AdjustmentBluePilot Teach-Turn for sensing range; IO-Link for parameters and Smart Task functions
IndicatorsBlue: sensing range; green steady: power, flashing: IO-Link; yellow on: object present, off: object absent
Digital outputsTwo complementary push-pull PNP/NPN outputs; maximum current ≤100 mA
Switching modeLight/dark switching
PNP signal voltage HIGH/LOWApproximately Ub−2.5 V / 0 V
NPN signal voltage HIGH/LOWApproximately Ub / <2.5 V
Response time≤500 µs with resistive load in basic switching mode
Response-time repeatability150 µs in basic switching mode
Switching frequency1,000 Hz at 1:1 light/dark ratio in basic switching mode
IO-LinkV1.1; COM2, 38.4 kBaud; 2.3 ms cycle
IO-Link process data16 bit: bit 0=QL1, bit 1=QL2, bits 2–15 empty
IO-Link identificationVendorID 26; DeviceID 0x800178 / 8388984
Master port and SIOType A master port; SIO mode supported
Smart Task logicBase logics: direct, AND, OR, window and hysteresis; inverter available
Smart Task timersDeactivated; switch-on delay; off delay; ON and OFF delay; impulse (one shot)
Smart Task timingSIO logic: 800 Hz, 600 µs response, 300 µs repeatability; IO-Link logic: 650 Hz, 750 µs response, 400 µs repeatability
DiagnosisDevice status and quality of teach
ConnectionM12 four-pin male connector
Pin assignment1 BN=L+; 2 WH=MF, factory complementary dark output; 3 BU=M; 4 BK=QL1/C, factory light output and IO-Link (CD-390)
Output configurationPin 2 and pin 4 functions configurable through IO-Link; switching outputs must not be connected to another output
Power supply10–30 V DC, limit values
Ripple≤5 Vpp
Current consumption≤30 mA without load at 24 V DC
Output protectionReverse-polarity, overcurrent and short-circuit protected
Protection classIII
Usage categoryDC-12 / DC-13, EN 60947-5-2
Housing and connector materialVISTAL plastic
Front screen materialPMMA plastic
IP ratingIP66, IP67 and IP69, EN 60529; IP69 replaces IP69K under ISO 20653:2013-03
Operating temperature−40 to +60 °C
Storage temperature−40 to +75 °C
Relative humidity35–95%, noncondensing
Mounting holesØ5.2 mm
Maximum fixing-screw torque1.3 Nm
Shock resistance50 g, 11 ms, 150 shocks total; 50 g, 6 ms, 30,000 shocks total; EN 60068-2-27
Vibration resistance10–2,000 Hz, 0.5 mm / 10 g, 20 sweeps per axis, 1 octave/min; EN 60068-2-6
EMCEN 60947-5-2
Cleaning-agent resistanceECOLAB
MTTFD626 years
DCavg0%
Mission time20 years
Physical Weight (kg)0.08

Industrial Applications

1. Counting separated cartons against a farther background

A conveyor can present separated cartons within the adjusted sensing region while a farther surface remains behind them. BluePilot sets the target distance, and background suppression establishes the detection boundary for the actual carton surfaces. External counting logic receives the switching condition, with commissioning checking target remission, background separation, spacing and timing in the selected operating mode.

Problem Solved

A target-passage reference helps external counting logic register separated cartons from one mounting side, with the adjusted boundary checked against the real carton and background combination.

Carton counting Background suppression BluePilot setting

2. Checking a load on a presented carrier

A handling station can present a carrier so the expected load lies inside the adjusted target region and the empty carrier lies farther away. BluePilot sets the boundary using representative loaded and empty carriers. External inspection logic samples the complementary outputs after presentation, while setup checks surface remission, placement tolerance and the required separation from the background.

Problem Solved

A load-present reference helps external inspection logic distinguish a loaded carrier from an empty presentation, supporting an omitted-load check before the next handling step.

Load inspection Carrier presentation Complementary outputs

3. Applying a configured delay to a process condition

A process station can use background-suppression detection as its input condition and configure an available Smart Task timer through IO-Link. A switch-on delay or off delay changes how that condition reaches external sequencing logic. Commissioning selects the intended function and verifies resulting behavior using the specified Smart Task response and switching limits, which differ from basic switching mode.

Problem Solved

A configured timer helps external sequencing logic use a deliberately delayed detection condition, supporting application-specific timing without assuming the basic switching-mode response applies to Smart Task processing.

Configured timer Smart Task IO-Link setup

Additional information

Weight 0.101 kg
Dimensions 5.8 × 5.3 × 10 cm