SICK 6053542 UM12-1172211 PNP Ultrasonic Sensor

USD 390.26

UM12-1172211 offers 20–150 mm ultrasonic operation, one PNP output, external teach-in, temperature compensation and an IP65/IP67 M12 threaded housing.

SKU: SICK-6053542 Category:

Description

Ultrasonic Distance Sensors - SICK UM12

SICK UM12-1172211 PNP Ultrasonic Distance Sensor

BrandSICK
Model IdentifierUM12-1172211
Official Part Number6053542

Technical Overview

The SICK UM12-1172211 uses ultrasonic echoes to detect natural objects within a 20–150 mm operating range. One PNP output provides a taught switching condition, while switching-point, switching-window and background modes adapt evaluation to the installation. The 250 mm limiting range is separate from the operating range, and the detection area depends on target reflection, size and alignment. Temperature compensation supports distance evaluation; response is 24 ms, switching frequency 30 Hz and output time 8 ms. The cylindrical M12 ×1 body uses nickel-plated brass and PBT, with a straight sending axis, two LEDs and an M12 four-pin male connector. IP65/IP67 protection and −25 to+70 °C operation support machine installation.

20–150 mm ultrasonic sensor with one PNP switching output, external teach-in, temperature compensation, M12 threaded mounting and an M12 four-pin connector.

Key Features

  • 20–150 mm operating range;250 mm limiting range
  • One PNP digital output;maximum current≤200 mA
  • External teach-in;switching-point,window and background modes
  • 24 ms response;30 Hz switching;8 ms output time
  • Resolution≥0.069 mm;repeatability±0.15% with specified minimum
  • Temperature compensation;accuracy±1% of current measurement
  • M12 ×1 cylindrical body;straight sending axis
  • M12 four-pin male connector;two status LEDs
  • 10–30 V DC;≤0.75 W without load;initialization<300 ms
  • IP65/IP67;nickel-plated brass/PBT housing;−25 to+70 °C operation

Teach a distance-based switching condition for external machine control using ultrasonic echoes from the actual target.

Technical Specification Matrix

ParameterValue
Functional principleUltrasonic distance sensing
Measuring objectNatural objects
Operating range20–150 mm
Limiting range250 mm;distinct from operating range
Detection areaDepends on reflection properties,size and alignment;reference diagrams use aligned500 ×500 mm plate andØ10 mm cylindrical bar
Resolution≥0.069 mm
Repeatability±0.15% of current measured value;minimum value≥resolution
Measurement accuracy±1% of current measured value
Temperature compensationInternal;optimum operating point after1 min;factory setting uses aluminum mounting bracket and mounting nuts
Response time24 ms
Switching frequency30 Hz
Output time8 ms
Ultrasonic frequencyTypical380 kHz;acoustic frequency
Switching modesSwitching point(DtO),switching window,background(ObSB)
Output adjustmentExternal teach-in,invert digital output,reset to factory defaults
Digital output1 ×PNP;maximum output current≤200 mA
Hysteresis2 mm
Power supply10–30 V DC;limit values;reverse-polarity protected
Supply network requirementShort-circuit protected network,max8 A,Class2
Power consumption≤0.75 W without load
Initialization time<300 ms
IndicatorsGreen supply LED;orange switching-output LED
ConnectionM12 four-pin male connector
Pin assignment1BN=L+;3BU=M/0 V;4BK=Q/invertedQ;2WH=Teach-in
Mounting threadM12 ×1
Mounting nuts17 mm across flats;maximum tightening torque1 Nm
Sending axisStraight
Housing materialNickel-plated brass and PBT
Transducer materialsPolyurethane foam and glass epoxy resin
IP ratingIP65/IP67
Protection classIII
Operating temperature−25 to+70 °C
Storage temperature−40 to+85 °C
MTTFD101 years
DCavg0%
Physical Weight (kg)0.015

Industrial Applications

1. Detecting a part at a fixture reference

A fixture can present a sufficiently reflecting part surface within the 20–150 mm operating range and teach the required switching point through the external input. The selected PNP output reports the configured distance condition to machine control. Target size and angle are checked during alignment, and the24 ms response is included when matching the inspection step to the machine sequence.

Problem Solved

A taught distance condition gives external control a repeatable reference for a part surface, helping identify a positional change instead of relying only on visual confirmation at the fixture.

Fixture reference Teach-in Switching output

2. Checking a short-range fill level

A compact container can present a liquid or bulk-material surface within 20–150 mm, provided that the actual surface returns a usable echo. The sensor is aligned and taught at the selected level condition, with its 250 mm limiting range kept separate from the operating span. External control interprets the switching output, and application trials account for surface movement and the temperature-compensation settling period.

Problem Solved

Ultrasonic level switching supplies an external replenishment or filling controller with a defined surface-distance condition, reducing the need to judge a changing material level by eye.

Fill-level threshold Echo validation Temperature compensation

3. Checking a load within a taught position window

A handling station can teach two window boundaries around the expected position of an adequately reflecting load face inside 20–150 mm. The output then communicates the configured distance-window condition to external sequence control. The installation is validated with the actual target alignment and size, and the30 Hz switching limit is considered for the expected presentation cycle.

Problem Solved

A distance window helps external control distinguish an acceptably positioned load from one displaced outside the permitted zone, adding a positional condition to the handling sequence before the next action.

Position window Handling sequence Ultrasonic detection