Description
Festo VMPA1-M1H-M-PI Solenoid Valve
Technical Overview
The Festo VMPA1-M1H-M-PI is a 10 mm single-solenoid 5/2-way valve with pneumatic spring reset and 24 V DC actuation. Its soft-sealing piston-gate design provides reversible flow and documented vacuum suitability across a −0.9 to 10 bar working range. Standard nominal flow is 360 l/min, also specified for a QS-6 arrangement; that rating does not establish that fittings are supplied. A separate 3–8 bar pilot-pressure requirement governs pneumatic actuation. Switching times are 11 ms on and 20 ms off. The 49 g die-cast aluminium valve includes signal indication and detenting/non-detenting override, with through-hole mounting and IP65 protection.
10 mm single-solenoid 5/2 valve with pneumatic spring reset, 360 l/min nominal flow, 24 V DC actuation and vacuum suitability.
Key Features
- Single-solenoid 5/2-way function with pneumatic spring reset
- 10 mm valve size and soft-sealed piston-gate design
- 360 l/min standard nominal flow, also specified with QS-6 arrangement
- 24 V DC operation with ±25% permissible voltage variation
- −0.9 to 10 bar working range and separate 3–8 bar pilot pressure
- Reversible flow direction and documented vacuum suitability
- 11 ms switch-on and 20 ms switch-off times
- Signal indication and detenting/non-detenting manual override
- IP65 protection; 0.25 Nm maximum valve-mounting torque
- 49 g die-cast aluminium body with NBR seals; −5 to 50 °C ambient/media range
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 5/2-way, single solenoid |
| Type of actuation | Electrical |
| Valve size | 10 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 360 l/min |
| Operating voltage | 24 V DC |
| Operating pressure | -0.09 MPa...1 MPa; -0.9 bar...10 bar |
| Design | Piston gate valve |
| Type of reset | Pneumatic spring |
| Approval | c UL us - Recognised (Oil) |
| Degree of protection | IP65; To IEC 60529 |
| Sealing principle | Soft |
| Mounting position | Any |
| Manual override | Detenting; Non-detenting |
| Type of piloting | Piloted |
| Flow direction | Reversible |
| lap | Overlap |
| Signal status display | Yes |
| Pilot pressure | 0.3 MPa...0.8 MPa; 3 bar...8 bar |
| Suitability for vacuum | Yes |
| Standard nominal flow rate with QS-6 | 360 l/min |
| Switching time off | 20 ms |
| Switching time on | 11 ms |
| Max. positive test pulse with 0 signal | 400 µs |
| Max. negative test pulse with 1 signal | 200 µs |
| Permissible voltage fluctuations | +/-25% |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 1 - Low corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Storage temperature | -20 °C...40 °C |
| Media temperature | -5 °C...50 °C |
| Relative air humidity | Max. 90% at 40 °C |
| Ambient temperature | -5 °C...50 °C |
| Max. tightening torque for valve mounting | 0.25 Nm |
| Physical Weight (kg) | 0.049 |
| Type of mounting | With through-hole |
| Note on materials | RoHS compliant |
| Material seals | NBR |
| Material housing | Die-cast aluminium |
Industrial Applications
1. Direction Control for a Double-Acting Transfer Cylinder
A transfer fixture needs to alternate supply and exhaust between two cylinder chambers. The valve provides a single-solenoid 5/2-way routing function with pneumatic spring reset, using 24 V DC electrical actuation and a separate 3–8 bar pilot-pressure requirement. Its 360 l/min standard nominal flow and 10 mm valve size define the selected component at the pneumatic station.
Five-port switching supplies the two directional routing states needed by the cylinder, while pneumatic spring reset provides the specified alternate state for the machine command sequence.
2. Vacuum-Circuit Path Switching
A handling circuit needs a directional valve whose working paths can operate below atmospheric pressure. This model is explicitly suitable for vacuum and permits working pressure down to −0.9 bar with reversible flow. A separate 3–8 bar pilot requirement supplies the actuation condition while the working circuit follows the selected vacuum and venting connections.
Documented vacuum suitability permits switching of sub-atmospheric working paths, while the separate pilot-pressure range defines the positive-pressure actuation needed for that vacuum circuit arrangement.
3. Valve-Station Commissioning
During assembly of a pneumatic valve station, technicians need to exercise routing states and correlate electrical commands with the installed valve. The detenting and non-detenting manual override provides local actuation, while signal indication makes the commanded condition visible. The 10 mm valve uses through-hole mounting with a specified 0.25 Nm maximum valve-mounting torque for installation.
Manual actuation and visible signal indication support local routing checks during commissioning, helping technicians relate the electrical command to the selected pneumatic path at the valve station.