Description
Festo VSVA-B-P53C-ZD-D2-1T1L Solenoid Valve
Technical Overview
The Festo VSVA-B-P53C-ZD-D2-1T1L is a 24 V DC 5/3-way solenoid valve with a closed centre and ISO 5599-2 size 2 sub-base interfaces. External pilot air at 3–10 bar supports a working-pressure range of −0.9 to 10 bar. Standard nominal flow is 2800 l/min, with separately specified valve-only and individual-sub-base flows of 3600 and 3200 l/min. The 52 mm-wide unit uses an ISO plug-in electrical connection, LED indication and current reduction from 165 mA pickup to 35 mA after 30 ms per coil. IP65/NEMA 4 protection, a 780 g product weight and −5 to +50 °C ambient range characterize the assembly.
24 V DC 5/3-way closed-centre valve with ISO 5599-2 size 2 sub-base interface, 2800 l/min nominal flow and external pilot supply.
Key Features
- 5/3-way closed-centre directional function
- ISO 5599-2 size 2 pneumatic and electrical interfaces
- 2800 l/min standard nominal flow to DIN 1343
- 3600 l/min valve-only flow; 3200 l/min on an individual sub-base
- External pilot supply at 3–10 bar
- −0.9 to 10 bar working pressure and any flow direction
- 24 V DC coil with current reduction to 35 mA after 30 ms
- 23 ms on, 60 ms off and 30 ms reversal times
- IP65/NEMA 4 protection with LED indication and manual override
- 52 mm construction width, 59 mm mounting grid pitch and 780 g product weight
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 5/3-way, closed |
| Type of actuation | Electrical |
| Construction width | 52 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 2800 l/min |
| pneumatic working port | Sub-base size 2 to ISO 5599-2; G1/2 |
| Operating voltage | 24 V DC |
| Operating pressure | -0.09 MPa...1 MPa; -0.9 bar...10 bar |
| Design | Piston gate valve |
| Approval | c UL us - Recognised (Oil) |
| KC mark | KC-EMV |
| CE mark (see declaration of conformity) | To EU EMC Directive |
| Degree of protection | IP65; NEMA 4 |
| Mounting grid pitch | 59 mm |
| Exhaust-air function | Can be throttled; Via throttle plate; Via individual sub-base |
| Sealing principle | Soft |
| Mounting position | Any |
| Conforms to standard | ISO 5599-2 |
| Manual override | Detenting; Non-detenting |
| Type of piloting | Piloted |
| Pilot air supply | External |
| Flow direction | Any |
| Signal status display | LED |
| Pilot pressure | 0.3 MPa...1 MPa; 3 bar...10 bar |
| Flow rate of valve | 3600 l/min |
| Flow rate of valve on individual sub-base | 3200 l/min |
| Flow rate of pneumatically interlinked valve | 2800 l/min |
| Switching time off | 60 ms |
| Switching time on | 23 ms |
| Switching time reversal | 30 ms |
| Duty cycle | 100% |
| Max. positive test pulse with 0 signal | 1000 µs |
| Max. negative test pulse with 1 signal | 3500 µs |
| Nominal pick-up current per solenoid coil | 165 mA to 30 ms |
| Nominal current with current reduction | 35 mA after 30 ms |
| Characteristic coil data | 24 V DC: 4.6 W |
| Immunity to surge | 2.5 kV |
| Pollution degree | 3 |
| Permissible voltage fluctuations | +/-10% |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 0 - No corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Media temperature | -5 °C...50 °C |
| Relative air humidity | 0 - 90% |
| Ambient temperature | -5 °C...50 °C |
| Physical Weight (kg) | 0.78 |
| Electrical connection | Plug-in; To ISO 5599-2 |
| Type of mounting | On sub-base |
| Pilot air port 12/14 | Sub-base size 2 to ISO 5599-2 |
| Pilot exhaust port 82/84 | Ducted; Not ducted as per standard; Either: |
| Pneumatic connection, port 1 | Sub-base size 2 to ISO 5599-2 |
| Pneumatic connection, port 2 | Sub-base size 2 to ISO 5599-2 |
| Pneumatic connection, port 3 | Sub-base size 2 to ISO 5599-2 |
| Pneumatic connection, port 4 | Sub-base size 2 to ISO 5599-2 |
| Pneumatic connection, port 5 | Sub-base size 2 to ISO 5599-2 |
| Note on materials | RoHS compliant |
| Material seals | Fluoro rubber; HNBR; NBR |
| Material housing | Die-cast aluminium; PA |
| Material screws | Galvanised steel |
Industrial Applications
1. Three-State Linear Transfer Control
A pneumatic transfer axis needs extension, retraction and a neutral command between machine steps. The 5/3-way valve supplies two directional states and a closed-centre routing state for a suitable double-acting cylinder circuit. Its ISO 5599-2 size 2 interface and 2800 l/min standard nominal flow provide a documented mounting and flow basis for the control assembly, with external pilot air supplied separately to the working circuit.
A closed-centre third state blocks the valve's working paths between directional commands, giving the controller a distinct neutral circuit state alongside the two movement commands.
2. Vacuum-Compatible Directional Routing
A pneumatic handling circuit needs directional routing at working pressures below atmospheric pressure while keeping a positive pilot-air supply. This valve permits working pressure down to −0.9 bar and uses an external 3–10 bar pilot supply. Any flow direction is specified, allowing the working circuit arrangement to be evaluated separately from pilot actuation while retaining the closed-centre valve's three routing states.
External piloting separates the positive actuation pressure from the negative-pressure working circuit, providing documented directional switching capability without assuming the working vacuum can supply pilot actuation.
3. Reversible Pneumatic Motor Command Circuit
A machine uses a suitable reversible pneumatic motor for a winding or positioning task and needs forward, reverse and neutral air-routing commands. The 5/3-way arrangement supplies those circuit states through the ISO size 2 sub-base interface. Its 30 ms reversal time characterizes the valve component, while the motor's run-down and stopping behavior remain properties of the motor, load and complete pneumatic circuit.
One directional valve provides forward, reverse and neutral routing commands through its electrical plug-in interface, allowing the machine controller to select the required pneumatic circuit state.