Description
SICK UM12-1192251 NPN Ultrasonic Distance Sensor
Technical Overview
The SICK UM12-1192251 uses ultrasonic echoes to detect natural objects within a 40–240 mm operating range. One NPN output provides a taught switching condition, while switching-point, switching-window and background modes adapt evaluation to the installation. The 350 mm limiting range is separate from the operating range, and the detection area depends on target reflection, size and alignment. Temperature compensation supports distance evaluation; response is 30 ms, switching frequency 25 Hz and output time 10 ms. The cylindrical M12 ×1 body uses nickel-plated brass and PBT, with a straight sending axis, two LEDs and an M12 four-pin male connector. IP65/IP67 protection and −25 to+70 °C operation support machine installation.
40–240 mm ultrasonic sensor with one NPN switching output, external teach-in, temperature compensation, M12 threaded mounting and an M12 four-pin connector.
Key Features
- 40–240 mm operating range;350 mm limiting range
- One NPN digital output;maximum current≤200 mA
- External teach-in;switching-point,window and background modes
- 30 ms response;25 Hz switching;10 ms output time
- Resolution≥0.069 mm;repeatability±0.15% with specified minimum
- Temperature compensation;accuracy±1% of current measurement
- M12 ×1 cylindrical body;straight sending axis
- M12 four-pin male connector;two status LEDs
- 10–30 V DC;≤1.05 W without load;initialization<300 ms
- IP65/IP67;nickel-plated brass/PBT housing;−25 to+70 °C operation
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Functional principle | Ultrasonic distance sensing |
| Measuring object | Natural objects |
| Operating range | 40–240 mm |
| Limiting range | 350 mm;distinct from operating range |
| Detection area | Depends on reflection properties,size and alignment;reference diagrams use aligned500 ×500 mm plate andØ10 mm cylindrical bar |
| Resolution | ≥0.069 mm |
| Repeatability | ±0.15% of current measured value;minimum value≥resolution |
| Measurement accuracy | ±1% of current measured value |
| Temperature compensation | Internal;optimum operating point after1 min;factory setting uses aluminum mounting bracket and mounting nuts |
| Response time | 30 ms |
| Switching frequency | 25 Hz |
| Output time | 10 ms |
| Ultrasonic frequency | Typical500 kHz;acoustic frequency |
| Switching modes | Switching point(DtO),switching window,background(ObSB) |
| Output adjustment | External teach-in,invert digital output,reset to factory defaults |
| Digital output | 1 ×NPN;maximum output current≤200 mA |
| Hysteresis | 3 mm |
| Power supply | 10–30 V DC;limit values;reverse-polarity protected |
| Supply network requirement | Short-circuit protected network,max8 A,Class2 |
| Power consumption | ≤1.05 W without load |
| Initialization time | <300 ms |
| Indicators | Green supply LED;orange switching-output LED |
| Connection | M12 four-pin male connector |
| Pin assignment | 1BN=L+;3BU=M/0 V;4BK=Q/invertedQ;2WH=Teach-in |
| Mounting thread | M12 ×1 |
| Mounting nuts | 17 mm across flats;maximum tightening torque1 Nm |
| Sending axis | Straight |
| Housing material | Nickel-plated brass and PBT |
| Transducer materials | Polyurethane foam and glass epoxy resin |
| IP rating | IP65/IP67 |
| Protection class | III |
| Operating temperature | −25 to+70 °C |
| Storage temperature | −40 to+85 °C |
| MTTFD | 101 years |
| DCavg | 0% |
| Physical Weight (kg) | 0.015 |
Industrial Applications
1. Detecting a part at a fixture reference
A fixture can present a sufficiently reflecting part surface within the 40–240 mm operating range and teach the required switching point through the external input. The selected NPN output reports the configured distance condition to machine control. Target size and angle are checked during alignment, and the30 ms response is included when matching the inspection step to the machine sequence.
A taught distance condition gives external control a repeatable reference for a part surface, helping identify a positional change instead of relying only on visual confirmation at the fixture.
2. Checking a short-range fill level
A compact container can present a liquid or bulk-material surface within 40–240 mm, provided that the actual surface returns a usable echo. The sensor is aligned and taught at the selected level condition, with its 350 mm limiting range kept separate from the operating span. External control interprets the switching output, and application trials account for surface movement and the temperature-compensation settling period.
Ultrasonic level switching supplies an external replenishment or filling controller with a defined surface-distance condition, reducing the need to judge a changing material level by eye.
3. Checking a load within a taught position window
A handling station can teach two window boundaries around the expected position of an adequately reflecting load face inside 40–240 mm. The output then communicates the configured distance-window condition to external sequence control. The installation is validated with the actual target alignment and size, and the25 Hz switching limit is considered for the expected presentation cycle.
A distance window helps external control distinguish an acceptably positioned load from one displaced outside the permitted zone, adding a positional condition to the handling sequence before the next action.