Description
Festo VUVG-S10-M52-RZT-M5-1T1L 5/2-Way Solenoid Valve
Technical Overview
The Festo VUVG-S10-M52-RZT-M5-1T1L is a 10 mm single-solenoid valve with a 5/2-way function, M5 working ports and mechanical/pneumatic spring reset. External pilot air at 1.5–8 bar operates the piston gate valve independently of its −0.9 to 10 bar working circuit. Standard nominal flow is 230 l/min, with reversible flow direction, 9 ms switch-on and 21 ms switch-off times. The valve operates at 24 V DC through an E-box; its coil data separately specify 22 V DC and 1.0 W. LED indication, manual override and IP65/IP67 protection support integration on a manifold rail.
10 mm 5/2-way single-solenoid valve with M5 ports, external pilot supply, spring reset, 230 l/min nominal flow and a 24 V DC E-box interface.
Key Features
- 5/2-way single-solenoid directional function
- 10 mm valve size with M5 working ports 2 and 4
- 230 l/min standard nominal flow rate to DIN 1343
- Mechanical and pneumatic spring reset specified
- −0.9 to 10 bar working pressure; 1.5–8 bar external pilot pressure
- Reversible flow direction and throttleable exhaust
- 24 V DC operation via E-box; coil data 22 V DC, 1.0 W
- 9 ms on and 21 ms off times; 3 Hz maximum switching frequency
- 100% duty cycle, LED indication and manual override
- IP65/IP67 protection; −5 to +60 °C ambient/media range
Technical Specification Matrix
| Parameter | Value |
|---|---|
| Valve function | 5/2-way, single solenoid |
| Type of actuation | Electrical |
| Valve size | 10 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 230 l/min |
| pneumatic working port | M5 |
| Operating voltage | 24 V DC |
| Operating pressure | -0.9 bar...10 bar |
| Design | Piston gate valve |
| Type of reset | Mechanical spring; Pneumatic spring |
| Approval | c UL us - Recognised (Oil) |
| Degree of protection | IP65; IP67 |
| Exhaust-air function | Can be throttled |
| Sealing principle | Soft |
| Mounting position | Any |
| Manual override | Detenting; Non-detenting |
| Type of piloting | Piloted |
| Pilot air supply | External |
| Flow direction | Reversible |
| lap | Overlap |
| Signal status display | LED |
| Pilot pressure | 0.15 MPa...0.8 MPa; 1.5 bar...8 bar |
| Max. switching frequency | 3 Hz |
| Switching time off | 21 ms |
| Switching time on | 9 ms |
| Duty cycle | 100% |
| Max. positive test pulse with 0 signal | 1600 µs |
| Max. negative test pulse with 1 signal | 3000 µs |
| Characteristic coil data | 22 V DC: 1.0 W |
| Permissible voltage fluctuations | +/-10% |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will; always be required) |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Media temperature | -5 °C...60 °C |
| Pilot medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Ambient temperature | -5 °C...60 °C |
| Physical Weight (kg) | 0.053 |
| Electrical connection | Via E-box |
| Type of mounting | On manifold rail |
| Pneumatic connection, port 2 | M5 |
| Pneumatic connection, port 4 | M5 |
| Note on materials | RoHS compliant |
| Material seals | HNBR; NBR |
| Material housing | Wrought aluminium alloy |
Industrial Applications
1. Reciprocating Part-Transfer Cylinder
An assembly machine uses a double-acting cylinder to transfer a component between two positions. The 5/2-way valve changes the air connections through M5 working ports using a solenoid command and spring reset. Its 10 mm size and manifold-rail mounting support a grouped pneumatic control assembly, while the E-box provides the electrical connection and LEDs show the signal state during commissioning.
A solenoid command and spring reset provide the two directional states needed for cylinder movement, while M5 connections and compact manifold mounting group the transfer controls.
2. Pneumatic Gripper Open-and-Close Sequencing
A handling unit uses a double-acting gripper whose working pressure is set separately from the valve actuation supply. External pilot air at 1.5–8 bar operates the single-solenoid 5/2-way valve independently of the working circuit. This arrangement supports a gripper circuit in which directional actuation and spring reset use a separate pilot-air supply arrangement.
Separate pilot air allows the valve actuation supply and gripper working pressure to be arranged independently, while a solenoid command and spring reset select the directional state.
3. Two-Position Product Diverter Actuation
A packaging conveyor uses a pneumatic actuator to move a product diverter between two routes. The valve changes the actuator air connections through its 5/2-way circuit, with 9 ms switch-on and 21 ms switch-off times. Its maximum switching frequency of 3 Hz provides a concrete valve limit for planning directional commands alongside actuator and load response.
Documented switch-on, switch-off and frequency ratings support planning diverter commands, while the 5/2-way valve provides the directional air routing and reset action required by the actuator circuit.